Richmond 10CE65-HP5S30 Water Heater Specifications (4.05 UEF)
The Richmond 10CE65-HP5S30 (Hybrid/Electric Heat Pump, Electric) achieves a certified 4.05 UEF rating across its 59-gallon nominal tank, 75 gal First Hour Rating, ranking #61 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 3387970). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +1.55 / +62.0%. Rated annual electricity draw of 1,289 kWh/yr equates to roughly $234/yr ($2,341 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH65 T2 FD400-30 (4.05 UEF).
- Uniform Energy Factor
- 4.05 UEF
- Cohort UEF Rank
- #61 of 706 (top 14.2%)
- First Hour Rating
- 75 gal
- Storage Volume
- 59 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.55 / +62.0%

Richmond 10CE65-HP5S30 (4.05 UEF) ranks #61 of 706 Hybrid/Electric Heat Pump models — 40-way tie; top 14.2%, more efficient than 85.8% of Hybrid/Electric Heat Pump models, +0.35 UEF above the 3.70 UEF median.
Federal 2029 margin for Richmond 10CE65-HP5S30: +1.55 UEF (+62.0%) vs. 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,289 kWh/yr for Richmond 10CE65-HP5S30 runs ~$234/yr vs. ~$1,030/yr for a 0.92 UEF electric tank.
State electric sensitivity for Richmond 10CE65-HP5S30: 10-year operating spend spans $1,886 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,082 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Peer comparison: Richmond 10CE65-HP5S30 (4.05 UEF) compares closely with Friedrich PROH65 T2 FD400-30 (4.05 UEF, at parity) and Rheem CPROPH65 T2 RH375-SO (4.05 UEF, at parity).
How Do Richmond 10CE65-HP5S30 Specs Compare to Hybrid/Electric Heat Pump Medians?
Richmond 10CE65-HP5S30 places #61 of 706 (top 14.2%) across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Richmond | 80 certified listings | ENERGY STAR PD 3387970 |
| Model Number | 10CE65-HP5S30 | Draw pattern: High-Usage | 10CE65-HP5S30 |
| Uniform Energy Factor (UEF) | 4.05 | +0.35 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 75 gal | +3 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,289 kWh/yr | +217 kWh/yr vs. 1,072 kWh/yr median | Est. $234/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 457% | +28.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 64.2" H x 24.3" D | Verify 72 in. vertical headroom; clears 28 in. utility doorway (24.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 24 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-15 | Certified 2026-10-15 | Markets: Canada |
What Does 10CE65-HP5S30 Cost to Operate Across State Electricity Rates?
At 1,289 kWh/yr, Richmond 10CE65-HP5S30 runs roughly $234/yr on the EIA national average tier under August 2026 Table 5.6.A rates.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $234/yr | $2,341 | $7,963 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $608/yr | $6,082 | $20,688 |
| California | 29.75 ¢/kWh ($0.2975) | $383/yr | $3,835 | $13,045 |
| Texas | 15.91 ¢/kWh ($0.1591) | $205/yr | $2,051 | $6,977 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $189/yr | $1,886 | $6,415 |
Are There Active CPSC Safety Recalls for Richmond Water Heaters?
Zero active CPSC recalls matched Richmond in our 2026-11-23 SaferProducts sweep; verify your individual tank date code via our lookup tool. See Serial Number Lookup.
Which Certified Water Heaters Match 10CE65-HP5S30 Most Closely?
These 5 competing Hybrid/Electric Heat Pump units sit nearest to Richmond 10CE65-HP5S30 by storage capacity and 4.05 UEF rating.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Friedrich PROH65 T2 FD400-30 | Hybrid/Electric Heat Pump | 59 gal | 75 gal | 4.05 (at parity) | 1,184 |
| Rheem CPROPH65 T2 RH375-SO | Hybrid/Electric Heat Pump | 59 gal | 75 gal | 4.05 (at parity) | 1,184 |
| Ruud CPROPH65 T2 CD375-30 | Hybrid/Electric Heat Pump | 59 gal | 75 gal | 4.05 (at parity) | 1,213 |
| Bosch TR7000T-65CA | Hybrid/Electric Heat Pump | 60 gal | 80 gal | 3.9 (-0.15) | 1,240 |
| Friedrich PROH65 T2 FD400-SO | Hybrid/Electric Heat Pump | 59 gal | 75 gal | 4.05 (at parity) | 1,184 |
Who Is Richmond 10CE65-HP5S30 Best For — and When Should You Pick Friedrich PROH65 T2 FD400-30?
Evaluate whether Richmond 10CE65-HP5S30's Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.
Key Limitations & Exclusions
- Richmond 10CE65-HP5S30 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Richmond 10CE65-HP5S30 directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
What Are the Key Questions About Richmond 10CE65-HP5S30?
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
How does Richmond 10CE65-HP5S30 (4.05 UEF) compare to 2029 federal DOE floors?
Evaluated against May 6, 2029 10 CFR 430.32 thresholds, Richmond 10CE65-HP5S30 records 4.05 UEF (Pass: +1.55 / +62.0%), placing #61 of 706 (top 14.2%) out of 706 certified Hybrid/Electric Heat Pump configurations.
Does Richmond 10CE65-HP5S30 fit inside a tight hallway closet or low-headroom utility room?
Richmond 10CE65-HP5S30 requires room for its 64.2 in. vertical shell and 24.3 in. diameter (verify 72 in. vertical headroom; clears 28 in. utility doorway (24.3" d)), plus service access for annual sediment draining.
What power supply or fuel line specs govern Richmond 10CE65-HP5S30?
For Richmond 10CE65-HP5S30, plan a 240V circuit at 24A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.
What annual utility bill should homeowners budget for Richmond 10CE65-HP5S30?
Using 1,289 kWh/yr, Richmond 10CE65-HP5S30 generates an estimated $234/yr electric bill at 18.16 cents/kWh (ranging from $189/yr in Washington hydro tiers up to $608/yr in Hawaii)—use the custom rate slider above for your utility tariff.
What are the main drawbacks of Richmond 10CE65-HP5S30 (4.05 UEF)?
Richmond 10CE65-HP5S30 requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or Friedrich PROH65 T2 FD400-30.
What hot-water delivery rating governs Richmond 10CE65-HP5S30?
Rated for 75 gal FHR (+3 gal vs. 72 gal median), Richmond 10CE65-HP5S30 prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.
Where do homeowners screen Richmond 10CE65-HP5S30 for recalls and tank age?
Verified clean against 2026-11-23 CPSC recall feeds for Richmond; use our browser-only serial decoder to inspect Richmond 10CE65-HP5S30's age and warranty window.
What alternative models sit closest to Richmond 10CE65-HP5S30 in the Hybrid/Electric Heat Pump class?
Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH65 T2 FD400-30 (4.05 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)