Ruud CPROPH65 T2 CD375-30 Water Heater Specifications (4.05 UEF)
In the 706-unit Hybrid/Electric Heat Pump class, Ruud CPROPH65 T2 CD375-30 (Electric) achieves a certified 4.05 UEF rating across its 59-gallon nominal tank, 75 gal First Hour Rating (rank #61 of 706, PD 4518084) and verifies as Pass: +1.55 / +62.0% for 2029 DOE floors. Rated annual electricity draw of 1,213 kWh/yr equates to roughly $220/yr ($2,203 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH65 T2 FD400-30 (4.05 UEF).
- Uniform Energy Factor
- 4.05 UEF
- Cohort UEF Rank
- #61 of 706 (top 14.2%)
- First Hour Rating
- 75 gal
- Storage Volume
- 59 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.55 / +62.0%

Ruud CPROPH65 T2 CD375-30 records 4.05 UEF efficiency, putting it #61 of 706 among 706 Hybrid/Electric Heat Pump peers.
10 CFR 430.32(d)(2) compliance: Ruud CPROPH65 T2 CD375-30 exceeds 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +1.55 UEF (+62.0%). At EIA August 2026 national rates (18.16 cents/kWh), 1,213 kWh/yr for Ruud CPROPH65 T2 CD375-30 runs ~$220/yr vs. ~$970/yr for a 0.92 UEF electric tank.
State electric sensitivity for Ruud CPROPH65 T2 CD375-30: 10-year operating spend spans $1,775 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,723 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Competing options beside Ruud CPROPH65 T2 CD375-30 (4.05 UEF) are Friedrich PROH65 T2 FD400-30 (4.05 UEF, at parity) and Rheem CPROPH65 T2 RH375-SO (4.05 UEF, at parity).
What Physical and Thermal Ratings Define Ruud CPROPH65 T2 CD375-30?
Positioning at #61 of 706 (top 14.2%) out of 706 Hybrid/Electric Heat Pump peers, Ruud CPROPH65 T2 CD375-30 pairs measured UEF performance with specific clearance and wiring rules.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Ruud | 95 certified listings | ENERGY STAR PD 4518084 |
| Model Number | CPROPH65 T2 CD375-30 | Draw pattern: High-Usage | CPROPH65 T2 CD375-30 |
| Uniform Energy Factor (UEF) | 4.05 | +0.35 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 75 gal | +3 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,213 kWh/yr | +141 kWh/yr vs. 1,072 kWh/yr median | Est. $220/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 457% | +28.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 74.2" H x 24.3" D | Needs >72 in. overhead clearance; clears 28 in. utility doorway (24.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-15 | Certified 2026-10-15 | Markets: Canada |
Why Do State Utility Rates Shift CPROPH65 T2 CD375-30 Running Costs?
Consuming 1,213 kWh annually puts Ruud CPROPH65 T2 CD375-30 near $220/yr at US baseline tariffs, with multi-state EIA comparisons charted below.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $220/yr | $2,203 | $7,495 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $572/yr | $5,723 | $19,471 |
| California | 29.75 ¢/kWh ($0.2975) | $361/yr | $3,609 | $12,278 |
| Texas | 15.91 ¢/kWh ($0.1591) | $193/yr | $1,930 | $6,566 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $177/yr | $1,775 | $6,038 |
Have Any Ruud Series Triggered CPSC Recalls?
SaferProducts records retrieved 2026-11-23 list 2 brand notices under Ruud; inspect model coverage dates prior to valve or anode service. See Serial Number Lookup.
- Recall #07108 (2007-02-21): Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard (CPSC Notice)
- Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)
What Are 5 Direct Alternatives to Ruud CPROPH65 T2 CD375-30?
Homeowners cross-shopping Ruud CPROPH65 T2 CD375-30 frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Friedrich PROH65 T2 FD400-30 | Hybrid/Electric Heat Pump | 59 gal | 75 gal | 4.05 (at parity) | 1,184 |
| Rheem CPROPH65 T2 RH375-SO | Hybrid/Electric Heat Pump | 59 gal | 75 gal | 4.05 (at parity) | 1,184 |
| Richmond 10CE65-HP5S30 | Hybrid/Electric Heat Pump | 59 gal | 75 gal | 4.05 (at parity) | 1,289 |
| Bosch TR7000T-65CA | Hybrid/Electric Heat Pump | 60 gal | 80 gal | 3.9 (-0.15) | 1,240 |
| Friedrich PROH65 T2 FD400-SO | Hybrid/Electric Heat Pump | 59 gal | 75 gal | 4.05 (at parity) | 1,184 |
When Should Homeowners Skip Ruud CPROPH65 T2 CD375-30 (Hybrid/Electric Heat Pump)?
Check Ruud CPROPH65 T2 CD375-30's mechanical constraints—including utility space, Electric capacity, and Pass: +1.55 / +62.0% status—against typical residential installations.
Key Limitations & Exclusions
- Ruud CPROPH65 T2 CD375-30 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Ruud CPROPH65 T2 CD375-30 directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Sizing, Efficiency & Recall Answers for Ruud CPROPH65 T2 CD375-30
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Will Ruud CPROPH65 T2 CD375-30 stay compliant after the May 6, 2029 DOE standard takes effect?
Tested at 4.05 UEF, Ruud CPROPH65 T2 CD375-30 shows Pass: +1.55 / +62.0% relative to May 6, 2029 federal DOE limits while placing #61 of 706 (top 14.2%) among 706 Hybrid/Electric Heat Pump peers like Friedrich PROH65 T2 FD400-30.
Will Ruud CPROPH65 T2 CD375-30 fit through a standard utility door and 72-inch basement ceiling?
Measuring 74.2 in. tall by 24.3 in. diameter, Ruud CPROPH65 T2 CD375-30 notes: needs >72 in. overhead clearance; clears 28 in. utility doorway (24.3" d). Reserve space above the jacket for T&P piping and anode removal.
Do existing utility hookups support Ruud CPROPH65 T2 CD375-30 during replacement?
Electrical specs for Ruud CPROPH65 T2 CD375-30 call for 240V at 21A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.
What is the estimated 10-year operating spend for Ruud CPROPH65 T2 CD375-30?
At 18.16 cents/kWh national residential pricing, Ruud CPROPH65 T2 CD375-30's 1,213 kWh/yr draw equals roughly $220 annually or $2,200 across a 10-year horizon (ranging from $177/yr in Washington hydro tiers up to $572/yr in Hawaii).
When is Ruud CPROPH65 T2 CD375-30 a poor fit for a residential replacement?
Avoid placing Ruud CPROPH65 T2 CD375-30 directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.
What First Hour Rating or flow capacity does Ruud CPROPH65 T2 CD375-30 deliver?
With 75 gal FHR (+3 gal vs. 72 gal median), Ruud CPROPH65 T2 CD375-30 fits larger 3–5 person homes cleanly.
How do you verify manufacturing age and recall status on Ruud CPROPH65 T2 CD375-30?
CPSC SaferProducts records show 2 brand-level recall notices mentioning Ruud as of 2026-11-23, including #07108 (2007-02-21). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
Does Ruud CPROPH65 T2 CD375-30 qualify for DOE HEAR incentives after 25C expired?
After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Ruud CPROPH65 T2 CD375-30. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH65 T2 FD400-30 (4.05 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)