Skip to main content
ENERGY STAR water heater model · PD 4572768

Ruud PROUH65 T2 CD400-15 Water Heater Specifications (3.55 UEF)

With PD 4572768 certification, Ruud PROUH65 T2 CD400-15 (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.55 UEF rating across its 59-gallon nominal tank, 54 gal First Hour Rating, standing #414 of 706 across 706 peers with Pass: +1.05 / +42.0% for May 6, 2029. Rated annual electricity draw of 887 kWh/yr equates to roughly $161/yr ($1,611 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH65 T2 FD400-15 (3.55 UEF).

Uniform Energy Factor
3.55 UEF
Cohort UEF Rank
#414 of 706
First Hour Rating
54 gal
Storage Volume
59 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.05 / +42.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Ruud PROUH65 T2 CD400-15 at 3.55 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50Ruud PROUH65 T2 CD400-15: 3.55
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Ruud PROUH65 T2 CD400-15 relative to the cohort median.
Efficiency comparison & rule summary

ENERGY STAR certification places Ruud PROUH65 T2 CD400-15 at 3.55 UEF (#414 of 706; -0.15 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.

May 6, 2029 readiness: Ruud PROUH65 T2 CD400-15 stands +1.05 UEF (+42.0%) relative to 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 887 kWh/yr for Ruud PROUH65 T2 CD400-15 runs ~$161/yr vs. ~$622/yr for a 0.92 UEF electric tank.

State electric sensitivity for Ruud PROUH65 T2 CD400-15: 10-year operating spend spans $1,298 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,185 in Hawaii (Highest EIA State) (47.18 cents/kWh).

In the Hybrid/Electric Heat Pump tier, Friedrich PROH65 T2 FD400-15 (3.55 UEF, at parity) and Rheem CPROPH65 T2 RH375-15 (3.55 UEF, at parity) bracket Ruud PROUH65 T2 CD400-15.

How Complete Are the Certified Metrics for Ruud PROUH65 T2 CD400-15?

Standing at #414 of 706 among 706 certified Hybrid/Electric Heat Pump heaters, Ruud PROUH65 T2 CD400-15 brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRuud95 certified listingsENERGY STAR PD 4572768
Model NumberPROUH65 T2 CD400-15Draw pattern: Medium-UsagePROUH65 T2 CD400-15
Uniform Energy Factor (UEF)3.55-0.15 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)54 gal-18 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use887 kWh/yr-185 kWh/yr vs. 1,072 kWh/yr medianEst. $161/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency407%-22.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)64.2" H x 24.3" DVerify 72 in. vertical headroom; clears 28 in. utility doorway (24.3" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 12 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2026-03-24Certified 2026-03-24Markets: Canada

What Is the Projected Utility Bill for PROUH65 T2 CD400-15 by State?

At 887 kWh/yr, Ruud PROUH65 T2 CD400-15 averages about $161/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.

Estimated Annual Electricity Cost by State Rate (887 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$161.00/yrHawaii$418.00/yrCalifornia$264.00/yrTexas$141.00/yrWashington$130.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $161/yr $1,611 $4,605
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $418/yr $4,185 $11,965
California 29.75 ¢/kWh ($0.2975) $264/yr $2,639 $7,545
Texas 15.91 ¢/kWh ($0.1591) $141/yr $1,411 $4,035
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $130/yr $1,298 $3,710
Estimated electricity spend (887 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are Ruud Models Affected by Current CPSC Notices?

Review 2 brand-matched CPSC entries pulled 2026-11-23 for Ruud and confirm your serial tag before scheduling contractor service. See Serial Number Lookup.

2 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #07108 (2007-02-21): Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard (CPSC Notice)
  • Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)

Which 5 Models Offer Similar Output to PROUH65 T2 CD400-15?

Ordered by minimal capacity and UEF spread relative to Ruud PROUH65 T2 CD400-15, these five certified peers give direct replacement benchmarks.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Friedrich PROH65 T2 FD400-15 Hybrid/Electric Heat Pump 59 gal 54 gal 3.55 (at parity) 887
Rheem CPROPH65 T2 RH375-15 Hybrid/Electric Heat Pump 59 gal 54 gal 3.55 (at parity) 887
Richmond 10CE65-HP5U15 Hybrid/Electric Heat Pump 59 gal 54 gal 3.55 (at parity) 887
A. O. Smith HPACO-45 1**+AXST-66 1** Hybrid/Electric Heat Pump 60 gal 82 gal 3.7 (+0.15) 1,341
Rheem CPROPH65 T2 RH400-15 Hybrid/Electric Heat Pump 59 gal 54 gal 3.55 (at parity) 887

What Installation Caveats Apply Before Buying Ruud PROUH65 T2 CD400-15?

Even high-UEF units like Ruud PROUH65 T2 CD400-15 (3.55 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

Key Limitations & Exclusions

  • Ruud PROUH65 T2 CD400-15 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Ruud PROUH65 T2 CD400-15 directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Ruud PROUH65 T2 CD400-15 Strong Fit — 3.55 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Friedrich PROH65 T2 FD400-15 footprint.

Practical Specs & Code Questions for Ruud PROUH65 T2 CD400-15

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Is Ruud PROUH65 T2 CD400-15 eligible for continued manufacture past May 6, 2029?

At 3.55 UEF, Ruud PROUH65 T2 CD400-15 achieves Pass: +1.05 / +42.0% for the 2029 DOE standard and stands #414 of 706 against Friedrich PROH65 T2 FD400-15 and Rheem CPROPH65 T2 RH375-15.

How tall and wide is Ruud PROUH65 T2 CD400-15, and what service clearance is needed?

Physical dimensions for Ruud PROUH65 T2 CD400-15 are 64.2 in. height and 24.3 in. diameter (verify 72 in. vertical headroom; clears 28 in. utility doorway (24.3" d)); verify stair turns and drain pan width before delivery.

Will Ruud PROUH65 T2 CD400-15 require upgrading household electrical panels or gas piping?

Ruud PROUH65 T2 CD400-15 draws 240V at 12A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.

Is Ruud PROUH65 T2 CD400-15 economical to operate at 18.16 cents/kWh US electric rates?

Expect roughly $161/yr ($1,610 over 10 years) to power Ruud PROUH65 T2 CD400-15 at 887 kWh/yr under the 18.16 cents/kWh US average (ranging from $130/yr in Washington hydro tiers up to $418/yr in Hawaii).

Which installation bottlenecks limit Ruud PROUH65 T2 CD400-15?

If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, Ruud PROUH65 T2 CD400-15 drops into resistance mode more often.

How does Ruud PROUH65 T2 CD400-15 handle simultaneous showers and laundry?

Delivering 54 gal in the first hour (-18 gal vs. 72 gal median), Ruud PROUH65 T2 CD400-15 combines 59 gal tank storage with rapid burner/element recovery.

How long is the warranty on Ruud PROUH65 T2 CD400-15 and how do you decode its serial?

CPSC SaferProducts records show 2 brand-level recall notices mentioning Ruud as of 2026-11-23, including #07108 (2007-02-21). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

How do 2026 post-OBBBA rebates affect buying Ruud PROUH65 T2 CD400-15?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH65 T2 FD400-15 (3.55 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks