Skip to main content
ENERGY STAR water heater model · PD 4572767

Richmond 10CE65-HP5U30 Water Heater Specifications (4.05 UEF)

Engineered as a Electric Hybrid/Electric Heat Pump unit, Richmond 10CE65-HP5U30 achieves a certified 4.05 UEF rating across its 59-gallon nominal tank, 75 gal First Hour Rating and ranks #61 of 706 in its 706-model cohort (PD 4572767), recording Pass: +1.55 / +62.0% under 2029 DOE rules. Rated annual electricity draw of 1,184 kWh/yr equates to roughly $215/yr ($2,150 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH65 T2 FD400-30 (4.05 UEF).

Uniform Energy Factor
4.05 UEF
Cohort UEF Rank
#61 of 706 (top 14.2%)
First Hour Rating
75 gal
Storage Volume
59 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.55 / +62.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Richmond 10CE65-HP5U30 at 4.05 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50Richmond 10CE65-HP5U30: 4.05
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Richmond 10CE65-HP5U30 relative to the cohort median.
Efficiency comparison & rule summary

Within the 706-unit Hybrid/Electric Heat Pump cohort, Richmond 10CE65-HP5U30 logs 4.05 UEF and ranks #61 of 706.

Against 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF), Richmond 10CE65-HP5U30 holds a +1.55 UEF (+62.0%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 1,184 kWh/yr for Richmond 10CE65-HP5U30 runs ~$215/yr vs. ~$946/yr for a 0.92 UEF electric tank.

State electric sensitivity for Richmond 10CE65-HP5U30: 10-year operating spend spans $1,732 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,586 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Cross-shopping Richmond 10CE65-HP5U30 (4.05 UEF)? Check Friedrich PROH65 T2 FD400-30 (4.05 UEF, at parity) and Rheem CPROPH65 T2 RH375-SO (4.05 UEF, at parity).

What Physical and Thermal Ratings Define Richmond 10CE65-HP5U30?

Positioning at #61 of 706 (top 14.2%) out of 706 Hybrid/Electric Heat Pump peers, Richmond 10CE65-HP5U30 pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRichmond80 certified listingsENERGY STAR PD 4572767
Model Number10CE65-HP5U30Draw pattern: High-Usage10CE65-HP5U30
Uniform Energy Factor (UEF)4.05+0.35 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)75 gal+3 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,184 kWh/yr+112 kWh/yr vs. 1,072 kWh/yr medianEst. $215/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency457%+28.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)64.2" H x 24.3" DVerify 72 in. vertical headroom; clears 28 in. utility doorway (24.3" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 21 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2026-03-24Certified 2026-03-24Markets: Canada

Why Do State Utility Rates Shift 10CE65-HP5U30 Running Costs?

Consuming 1,184 kWh annually puts Richmond 10CE65-HP5U30 near $215/yr at US baseline tariffs, with multi-state EIA comparisons charted below.

Estimated Annual Electricity Cost by State Rate (1,184 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$215.00/yrHawaii$559.00/yrCalifornia$352.00/yrTexas$188.00/yrWashington$173.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $215/yr $2,150 $7,315
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $559/yr $5,586 $19,004
California 29.75 ¢/kWh ($0.2975) $352/yr $3,522 $11,983
Texas 15.91 ¢/kWh ($0.1591) $188/yr $1,884 $6,409
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $173/yr $1,732 $5,893
Estimated electricity spend (1,184 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Have Any Richmond Series Triggered CPSC Recalls?

SaferProducts screening on 2026-11-23 returned zero recall matches for Richmond; confirm tank age separately using the rating-plate serial pattern. See Serial Number Lookup.

What Are 5 Direct Alternatives to Richmond 10CE65-HP5U30?

Homeowners cross-shopping Richmond 10CE65-HP5U30 frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Friedrich PROH65 T2 FD400-30 Hybrid/Electric Heat Pump 59 gal 75 gal 4.05 (at parity) 1,184
Rheem CPROPH65 T2 RH375-SO Hybrid/Electric Heat Pump 59 gal 75 gal 4.05 (at parity) 1,184
Ruud CPROPH65 T2 CD375-30 Hybrid/Electric Heat Pump 59 gal 75 gal 4.05 (at parity) 1,213
Bosch TR7000T-65CA Hybrid/Electric Heat Pump 60 gal 80 gal 3.9 (-0.15) 1,240
Friedrich PROH65 T2 FD400-SO Hybrid/Electric Heat Pump 59 gal 75 gal 4.05 (at parity) 1,184

Who Is Richmond 10CE65-HP5U30 Best For — and When Should You Pick Friedrich PROH65 T2 FD400-30?

Evaluate whether Richmond 10CE65-HP5U30's Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.

Key Limitations & Exclusions

  • Richmond 10CE65-HP5U30 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Richmond 10CE65-HP5U30 directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Richmond 10CE65-HP5U30 Strong Fit — 4.05 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Friedrich PROH65 T2 FD400-30 footprint.

Sizing, Efficiency & Recall Answers for Richmond 10CE65-HP5U30

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does Richmond 10CE65-HP5U30 (4.05 UEF) compare to 2029 federal DOE floors?

Evaluated against May 6, 2029 10 CFR 430.32 thresholds, Richmond 10CE65-HP5U30 records 4.05 UEF (Pass: +1.55 / +62.0%), placing #61 of 706 (top 14.2%) out of 706 certified Hybrid/Electric Heat Pump configurations.

Does Richmond 10CE65-HP5U30 fit inside a tight hallway closet or low-headroom utility room?

Richmond 10CE65-HP5U30 requires room for its 64.2 in. vertical shell and 24.3 in. diameter (verify 72 in. vertical headroom; clears 28 in. utility doorway (24.3" d)), plus service access for annual sediment draining.

What power supply or fuel line specs govern Richmond 10CE65-HP5U30?

For Richmond 10CE65-HP5U30, plan a 240V circuit at 21A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.

What annual utility bill should homeowners budget for Richmond 10CE65-HP5U30?

Using 1,184 kWh/yr, Richmond 10CE65-HP5U30 generates an estimated $215/yr electric bill at 18.16 cents/kWh (ranging from $173/yr in Washington hydro tiers up to $559/yr in Hawaii)—use the custom rate slider above for your utility tariff.

What are the main drawbacks of Richmond 10CE65-HP5U30 (4.05 UEF)?

Richmond 10CE65-HP5U30 requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or Friedrich PROH65 T2 FD400-30.

What hot-water delivery rating governs Richmond 10CE65-HP5U30?

Rated for 75 gal FHR (+3 gal vs. 72 gal median), Richmond 10CE65-HP5U30 prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.

Where do homeowners screen Richmond 10CE65-HP5U30 for recalls and tank age?

Verified clean against 2026-11-23 CPSC recall feeds for Richmond; use our browser-only serial decoder to inspect Richmond 10CE65-HP5U30's age and warranty window.

What alternative models sit closest to Richmond 10CE65-HP5U30 in the Hybrid/Electric Heat Pump class?

Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH65 T2 FD400-30 (4.05 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks