Richmond 10E40-HP120MS Water Heater Specifications (2.8 UEF)
The Richmond 10E40-HP120MS (Hybrid/Electric Heat Pump, Electric) achieves a certified 2.8 UEF rating across its 36-gallon nominal tank, 45 gal First Hour Rating, ranking #695 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 3555265). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +0.50 / +21.7%. Rated annual electricity draw of 780 kWh/yr equates to roughly $142/yr ($1,416 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH40 T0 FD120-M (2.8 UEF).
- Uniform Energy Factor
- 2.8 UEF
- Cohort UEF Rank
- #695 of 706
- First Hour Rating
- 45 gal
- Storage Volume
- 36 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +0.50 / +21.7%

Richmond 10E40-HP120MS (2.8 UEF) ranks #695 of 706 Hybrid/Electric Heat Pump models — 10-way tie; more efficient than 0.3% of Hybrid/Electric Heat Pump models, -0.90 UEF below the 3.70 UEF median.
Federal 2029 margin for Richmond 10E40-HP120MS: +0.50 UEF (+21.7%) vs. 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 780 kWh/yr for Richmond 10E40-HP120MS runs ~$142/yr vs. ~$431/yr for a 0.92 UEF electric tank.
State electric sensitivity for Richmond 10E40-HP120MS: 10-year operating spend spans $1,141 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $3,680 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Peer comparison: Richmond 10E40-HP120MS (2.8 UEF) compares closely with Friedrich PROH40 T0 FD120-M (2.8 UEF, at parity) and Rheem PROPH40 T0 RH120-M (2.8 UEF, at parity).
How Complete Are the Certified Metrics for Richmond 10E40-HP120MS?
Standing at #695 of 706 among 706 certified Hybrid/Electric Heat Pump heaters, Richmond 10E40-HP120MS brings measurable deltas in recovery, footprint, and energy efficiency.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Richmond | 80 certified listings | ENERGY STAR PD 3555265 |
| Model Number | 10E40-HP120MS | Draw pattern: Low-Usage | 10E40-HP120MS |
| Uniform Energy Factor (UEF) | 2.8 | -0.90 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 45 gal | -27 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 780 kWh/yr | -292 kWh/yr vs. 1,072 kWh/yr median | Est. $142/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 387% | -42.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 62.3" H x 20.3" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 120 V / 4.5 A max | 120V plug-in retrofit circuit; slower heat-pump-only recovery | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-16 | Certified 2026-10-16 | Markets: United States |
What Is the Projected Utility Bill for 10E40-HP120MS by State?
At 780 kWh/yr, Richmond 10E40-HP120MS averages about $142/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $142/yr | $1,416 | $2,895 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $368/yr | $3,680 | $7,520 |
| California | 29.75 ¢/kWh ($0.2975) | $232/yr | $2,320 | $4,742 |
| Texas | 15.91 ¢/kWh ($0.1591) | $124/yr | $1,241 | $2,536 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $114/yr | $1,141 | $2,332 |
Are Richmond Models Affected by Current CPSC Notices?
Zero brand-level CPSC hazard notices matched Richmond in our 2026-11-23 feed; decode your water heater's serial number below to confirm warranty status. See Serial Number Lookup.
Which 5 Models Offer Similar Output to 10E40-HP120MS?
Ordered by minimal capacity and UEF spread relative to Richmond 10E40-HP120MS, these five certified peers give direct replacement benchmarks.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Friedrich PROH40 T0 FD120-M | Hybrid/Electric Heat Pump | 36 gal | 45 gal | 2.8 (at parity) | 780 |
| Rheem PROPH40 T0 RH120-M | Hybrid/Electric Heat Pump | 36 gal | 45 gal | 2.8 (at parity) | 780 |
| Ruud PROUH40 T0 RU120-M | Hybrid/Electric Heat Pump | 36 gal | 45 gal | 2.8 (at parity) | 780 |
| A. O. Smith CAHP-40 2** | Hybrid/Electric Heat Pump | 36 gal | 55 gal | 3.6 (+0.80) | 902 |
| Friedrich PROH40 T0 FD120-MSO | Hybrid/Electric Heat Pump | 36 gal | 45 gal | 2.8 (at parity) | 780 |
Which Home Setups Are NOT a Fit for Richmond 10E40-HP120MS?
Comparing Richmond 10E40-HP120MS against Friedrich PROH40 T0 FD120-M requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.
Key Limitations & Exclusions
- Richmond 10E40-HP120MS needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Richmond 10E40-HP120MS directly beside quiet bedrooms.
- Requires condensate drain routing and 120V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Practical Specs & Code Questions for Richmond 10E40-HP120MS
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
How does Richmond 10E40-HP120MS score under 10 CFR 430.32 May 2029 water heater minimums?
Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; Richmond 10E40-HP120MS logs 2.8 UEF (Pass: +0.50 / +21.7%) within the 706-unit Hybrid/Electric Heat Pump group.
What physical clearance dimensions apply when installing Richmond 10E40-HP120MS?
With a 62.3 in. height and 20.3 in. diameter, Richmond 10E40-HP120MS fits spaces matching: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" d), plus 6–12 in. above for plumbing shutoffs.
What 240V circuit or IFGC fuel line capacity fits Richmond 10E40-HP120MS?
Powered via 120V at 4.5A max, Richmond 10E40-HP120MS requires: 120V plug-in retrofit circuit; slower heat-pump-only recovery. Confirm double-pole breaker sizing and condensate pump outlet proximity.
How do state electricity prices change annual costs for Richmond 10E40-HP120MS?
Annual electric spend for Richmond 10E40-HP120MS (780 kWh/yr) averages $142/yr nationwide (ranging from $114/yr in Washington hydro tiers up to $368/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.
What homeowner setups should avoid choosing Richmond 10E40-HP120MS?
Homes lacking a condensate drain or 120V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on Richmond 10E40-HP120MS.
Is Richmond 10E40-HP120MS sized adequately for a 2-to-4-person household?
ENERGY STAR certifies Richmond 10E40-HP120MS at 45 gal First Hour Rating (-27 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.
Does Richmond have active CPSC SaferProducts notices affecting 10E40-HP120MS?
Zero CPSC recall alerts matched Richmond (2026-11-23 check). Keep your Richmond 10E40-HP120MS serial code handy to track standard 6-to-12-year OEM warranty coverage.
Which competing water heater matches Richmond 10E40-HP120MS (2.8 UEF) most closely?
State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for Richmond 10E40-HP120MS. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH40 T0 FD120-M (2.8 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)