Skip to main content
ENERGY STAR water heater model · PD 2408586

Richmond 10E50-HP530 Water Heater Specifications (3.88 UEF)

Certified at 3.88 UEF across its 45-gallon nominal tank, 67 gal First Hour Rating, Richmond 10E50-HP530 (Hybrid/Electric Heat Pump, Electric) places #165 of 706 out of 706 ENERGY STAR models (PD 2408586). Its May 6, 2029 10 CFR 430.32 status reads Pass: +1.58 / +68.7%. Rated annual electricity draw of 846 kWh/yr equates to roughly $154/yr ($1,536 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH50 T2 FD400-30 (3.88 UEF).

Uniform Energy Factor
3.88 UEF
Cohort UEF Rank
#165 of 706 (top 30.6%)
First Hour Rating
67 gal
Storage Volume
45 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.58 / +68.7%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Richmond 10E50-HP530 at 3.88 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30Richmond 10E50-HP530: 3.88
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Richmond 10E50-HP530 relative to the cohort median.
Efficiency comparison & rule summary

Tested at 3.88 UEF, Richmond 10E50-HP530 places #165 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (+0.18 UEF vs. 3.70 UEF median).

Richmond 10E50-HP530 clears 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.58 UEF (+68.7% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 846 kWh/yr for Richmond 10E50-HP530 runs ~$154/yr vs. ~$648/yr for a 0.92 UEF electric tank.

State electric sensitivity for Richmond 10E50-HP530: 10-year operating spend spans $1,238 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $3,991 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Closest alternatives to Richmond 10E50-HP530 include Friedrich PROH50 T2 FD400-30 (3.88 UEF, at parity) alongside Rheem CPROPH50 T2 RH375-SO (3.88 UEF, at parity).

How Do Richmond 10E50-HP530 Specs Compare to Hybrid/Electric Heat Pump Medians?

Richmond 10E50-HP530 places #165 of 706 (top 30.6%) across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRichmond80 certified listingsENERGY STAR PD 2408586
Model Number10E50-HP530Draw pattern: Medium-Usage10E50-HP530
Uniform Energy Factor (UEF)3.88+0.18 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)67 gal-5 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use846 kWh/yr-226 kWh/yr vs. 1,072 kWh/yr medianEst. $154/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency430%+1.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)61.8" H x 22.3" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.3" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 21 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2026-10-15Certified 2026-10-15Markets: United States

What Does 10E50-HP530 Cost to Operate Across State Electricity Rates?

At 846 kWh/yr, Richmond 10E50-HP530 runs roughly $154/yr on the EIA national average tier under August 2026 Table 5.6.A rates.

Estimated Annual Electricity Cost by State Rate (846 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$154.00/yrHawaii$399.00/yrCalifornia$252.00/yrTexas$135.00/yrWashington$124.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $154/yr $1,536 $4,943
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $399/yr $3,991 $12,842
California 29.75 ¢/kWh ($0.2975) $252/yr $2,517 $8,098
Texas 15.91 ¢/kWh ($0.1591) $135/yr $1,346 $4,331
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $124/yr $1,238 $3,982
Estimated electricity spend (846 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are There Active CPSC Safety Recalls for Richmond Water Heaters?

Zero active CPSC recalls matched Richmond in our 2026-11-23 SaferProducts sweep; verify your individual tank date code via our lookup tool. See Serial Number Lookup.

Which Certified Water Heaters Match 10E50-HP530 Most Closely?

These 5 competing Hybrid/Electric Heat Pump units sit nearest to Richmond 10E50-HP530 by storage capacity and 3.88 UEF rating.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Friedrich PROH50 T2 FD400-30 Hybrid/Electric Heat Pump 45 gal 67 gal 3.88 (at parity) 846
Rheem CPROPH50 T2 RH375-SO Hybrid/Electric Heat Pump 45 gal 67 gal 3.88 (at parity) 846
Ruud CPROPH50 T2 CD375-30 Hybrid/Electric Heat Pump 45 gal 67 gal 3.88 (at parity) 846
Bradford White RE2HP50**-1NCTT Hybrid/Electric Heat Pump 45 gal 65 gal 3.89 (+0.01) 835
Friedrich PROH50 T2 FD400-SO Hybrid/Electric Heat Pump 45 gal 67 gal 3.88 (at parity) 846

When Should Homeowners Skip Richmond 10E50-HP530 (Hybrid/Electric Heat Pump)?

Check Richmond 10E50-HP530's mechanical constraints—including utility space, Electric capacity, and Pass: +1.58 / +68.7% status—against typical residential installations.

Key Limitations & Exclusions

  • Richmond 10E50-HP530 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Richmond 10E50-HP530 directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Richmond 10E50-HP530 Strong Fit — 3.88 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Friedrich PROH50 T2 FD400-30 footprint.

What Are the Key Questions About Richmond 10E50-HP530?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Will Richmond 10E50-HP530 stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 3.88 UEF, Richmond 10E50-HP530 shows Pass: +1.58 / +68.7% relative to May 6, 2029 federal DOE limits while placing #165 of 706 (top 30.6%) among 706 Hybrid/Electric Heat Pump peers like Friedrich PROH50 T2 FD400-30.

Will Richmond 10E50-HP530 fit through a standard utility door and 72-inch basement ceiling?

Measuring 61.8 in. tall by 22.3 in. diameter, Richmond 10E50-HP530 notes: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.3" d). Reserve space above the jacket for T&P piping and anode removal.

Do existing utility hookups support Richmond 10E50-HP530 during replacement?

Electrical specs for Richmond 10E50-HP530 call for 240V at 21A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.

What is the estimated 10-year operating spend for Richmond 10E50-HP530?

At 18.16 cents/kWh national residential pricing, Richmond 10E50-HP530's 846 kWh/yr draw equals roughly $154 annually or $1,540 across a 10-year horizon (ranging from $124/yr in Washington hydro tiers up to $399/yr in Hawaii).

When is Richmond 10E50-HP530 a poor fit for a residential replacement?

Avoid placing Richmond 10E50-HP530 directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.

What First Hour Rating or flow capacity does Richmond 10E50-HP530 deliver?

With 67 gal FHR (-5 gal vs. 72 gal median), Richmond 10E50-HP530 fits larger 3–5 person homes cleanly.

How do you verify manufacturing age and recall status on Richmond 10E50-HP530?

Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for Richmond; verify exact manufacturing week for Richmond 10E50-HP530 using the Serial Number Lookup tool.

Does Richmond 10E50-HP530 qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Richmond 10E50-HP530. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH50 T2 FD400-30 (3.88 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks