Richmond 10E50-HP5U30 Water Heater Specifications (3.88 UEF)
Certified at 3.88 UEF across its 45-gallon nominal tank, 67 gal First Hour Rating, Richmond 10E50-HP5U30 (Hybrid/Electric Heat Pump, Electric) places #165 of 706 out of 706 ENERGY STAR models (PD 3554196). Its May 6, 2029 10 CFR 430.32 status reads Pass: +1.58 / +68.7%. Rated annual electricity draw of 846 kWh/yr equates to roughly $154/yr ($1,536 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH50 T2 FD400-30 (3.88 UEF).
- Uniform Energy Factor
- 3.88 UEF
- Cohort UEF Rank
- #165 of 706 (top 30.6%)
- First Hour Rating
- 67 gal
- Storage Volume
- 45 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.58 / +68.7%

Tested at 3.88 UEF, Richmond 10E50-HP5U30 places #165 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (+0.18 UEF vs. 3.70 UEF median).
Richmond 10E50-HP5U30 clears 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.58 UEF (+68.7% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 846 kWh/yr for Richmond 10E50-HP5U30 runs ~$154/yr vs. ~$648/yr for a 0.92 UEF electric tank.
State electric sensitivity for Richmond 10E50-HP5U30: 10-year operating spend spans $1,238 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $3,991 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Closest alternatives to Richmond 10E50-HP5U30 include Friedrich PROH50 T2 FD400-30 (3.88 UEF, at parity) alongside Rheem CPROPH50 T2 RH375-SO (3.88 UEF, at parity).
What Physical and Thermal Ratings Define Richmond 10E50-HP5U30?
Positioning at #165 of 706 (top 30.6%) out of 706 Hybrid/Electric Heat Pump peers, Richmond 10E50-HP5U30 pairs measured UEF performance with specific clearance and wiring rules.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Richmond | 80 certified listings | ENERGY STAR PD 3554196 |
| Model Number | 10E50-HP5U30 | Draw pattern: Medium-Usage | 10E50-HP5U30 |
| Uniform Energy Factor (UEF) | 3.88 | +0.18 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 67 gal | -5 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 846 kWh/yr | -226 kWh/yr vs. 1,072 kWh/yr median | Est. $154/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 430% | +1.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 61.8" H x 22.3" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-15 | Certified 2026-10-15 | Markets: United States |
Why Do State Utility Rates Shift 10E50-HP5U30 Running Costs?
Consuming 846 kWh annually puts Richmond 10E50-HP5U30 near $154/yr at US baseline tariffs, with multi-state EIA comparisons charted below.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $154/yr | $1,536 | $4,943 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $399/yr | $3,991 | $12,842 |
| California | 29.75 ¢/kWh ($0.2975) | $252/yr | $2,517 | $8,098 |
| Texas | 15.91 ¢/kWh ($0.1591) | $135/yr | $1,346 | $4,331 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $124/yr | $1,238 | $3,982 |
Have Any Richmond Series Triggered CPSC Recalls?
SaferProducts screening on 2026-11-23 returned zero recall matches for Richmond; confirm tank age separately using the rating-plate serial pattern. See Serial Number Lookup.
What Are 5 Direct Alternatives to Richmond 10E50-HP5U30?
Homeowners cross-shopping Richmond 10E50-HP5U30 frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Friedrich PROH50 T2 FD400-30 | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.88 (at parity) | 846 |
| Rheem CPROPH50 T2 RH375-SO | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.88 (at parity) | 846 |
| Ruud CPROPH50 T2 CD375-30 | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.88 (at parity) | 846 |
| Bradford White RE2HP50**-1NCTT | Hybrid/Electric Heat Pump | 45 gal | 65 gal | 3.89 (+0.01) | 835 |
| Friedrich PROH50 T2 FD400-SO | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.88 (at parity) | 846 |
What Are the Limitations of Richmond 10E50-HP5U30 and Who Should Not Install It?
Before ordering Richmond 10E50-HP5U30 (Hybrid/Electric Heat Pump, 3.88 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.
Key Limitations & Exclusions
- Richmond 10E50-HP5U30 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Richmond 10E50-HP5U30 directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Sizing, Efficiency & Recall Answers for Richmond 10E50-HP5U30
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Does Richmond 10E50-HP5U30 pass the May 6, 2029 federal DOE efficiency rule?
Richmond 10E50-HP5U30 carries a verified 3.88 UEF rating (Pass: +1.58 / +68.7%), ranking #165 of 706 (top 30.6%) across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.
What doorway width and ceiling height does Richmond 10E50-HP5U30 need?
Richmond 10E50-HP5U30 stands 61.8 in. high with a 22.3 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.3" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.
What gas pipe size or electrical breaker does Richmond 10E50-HP5U30 require?
Richmond 10E50-HP5U30 uses a 240V branch circuit at 21A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.
How much electricity or energy does Richmond 10E50-HP5U30 cost per year to run?
Rated at 846 kWh/yr, Richmond 10E50-HP5U30 costs about $154/yr ($1,540 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $124/yr in Washington hydro tiers up to $399/yr in Hawaii).
Who should NOT install Richmond 10E50-HP5U30, and what are its limits?
Richmond 10E50-HP5U30 (3.88 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.
How many bathrooms or people can Richmond 10E50-HP5U30 serve at peak demand?
Richmond 10E50-HP5U30 achieves a 67 gal First Hour Rating (-5 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.
Are there CPSC safety recalls or serial checks for Richmond 10E50-HP5U30?
No active CPSC recalls matched Richmond as of 2026-11-23. Always decode the serial tag on Richmond 10E50-HP5U30 because OEM tank/exchanger warranties span 6–12 years.
What 2026 rebates apply to Richmond 10E50-HP5U30, and what peer compares closest?
Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH50 T2 FD400-30 (3.88 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)