Richmond 10E65-HP120MS Water Heater Specifications (3.12 UEF)
Engineered as a Electric Hybrid/Electric Heat Pump unit, Richmond 10E65-HP120MS achieves a certified 3.12 UEF rating across its 59-gallon nominal tank, 63 gal First Hour Rating and ranks #654 of 706 in its 706-model cohort (PD 3555352), recording Pass: +0.62 / +24.8% under 2029 DOE rules. Rated annual electricity draw of 971 kWh/yr equates to roughly $176/yr ($1,763 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH65 T0 FD120-M (3.12 UEF).
- Uniform Energy Factor
- 3.12 UEF
- Cohort UEF Rank
- #654 of 706
- First Hour Rating
- 63 gal
- Storage Volume
- 59 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +0.62 / +24.8%

Within the 706-unit Hybrid/Electric Heat Pump cohort, Richmond 10E65-HP120MS logs 3.12 UEF and ranks #654 of 706.
Against 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF), Richmond 10E65-HP120MS holds a +0.62 UEF (+24.8%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 971 kWh/yr for Richmond 10E65-HP120MS runs ~$176/yr vs. ~$598/yr for a 0.92 UEF electric tank.
State electric sensitivity for Richmond 10E65-HP120MS: 10-year operating spend spans $1,421 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,581 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Cross-shopping Richmond 10E65-HP120MS (3.12 UEF)? Check Friedrich PROH65 T0 FD120-M (3.12 UEF, at parity) and Rheem PROPH65 T0 RH120-M (3.12 UEF, at parity).
Where Does Richmond 10E65-HP120MS Rank Against Peer Hybrid/Electric Heat Pump Units?
Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, Richmond 10E65-HP120MS holds #654 of 706; inspect footprint, circuit load, and efficiency deltas here.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Richmond | 80 certified listings | ENERGY STAR PD 3555352 |
| Model Number | 10E65-HP120MS | Draw pattern: Medium-Usage | 10E65-HP120MS |
| Uniform Energy Factor (UEF) | 3.12 | -0.58 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 63 gal | -9 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 971 kWh/yr | -101 kWh/yr vs. 1,072 kWh/yr median | Est. $176/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 398% | -31.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 64.2" H x 24.3" D | Verify 72 in. vertical headroom; clears 28 in. utility doorway (24.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 120 V / 12 A max | 120V plug-in retrofit circuit; slower heat-pump-only recovery | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-15 | Certified 2026-10-15 | Markets: United States, Canada |
How Much Electricity Does 10E65-HP120MS Use in Different States?
Estimated at $176/yr nationally (971 kWh/yr), 10-year utility spending for Richmond 10E65-HP120MS shifts sharply between low-rate hydro and coastal grids.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $176/yr | $1,763 | $4,217 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $458/yr | $4,581 | $10,955 |
| California | 29.75 ¢/kWh ($0.2975) | $289/yr | $2,889 | $6,908 |
| Texas | 15.91 ¢/kWh ($0.1591) | $154/yr | $1,545 | $3,694 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $142/yr | $1,421 | $3,397 |
Does CPSC Flag Any Safety Notices on Richmond Units?
No open CPSC recall alerts appeared for Richmond as of 2026-11-23; you can still decode exact manufacture month and warranty window below. See Serial Number Lookup.
Which Competing Hybrid/Electric Heat Pump Models Compare Closest to 10E65-HP120MS?
Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to Richmond 10E65-HP120MS's gallon capacity and 3.12 UEF efficiency.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Friedrich PROH65 T0 FD120-M | Hybrid/Electric Heat Pump | 59 gal | 63 gal | 3.12 (at parity) | 971 |
| Rheem PROPH65 T0 RH120-M | Hybrid/Electric Heat Pump | 59 gal | 63 gal | 3.12 (at parity) | 971 |
| Ruud PROUH65 T0 RU120-M | Hybrid/Electric Heat Pump | 59 gal | 63 gal | 3.12 (at parity) | 971 |
| A. O. Smith HPACO-45 1**+AXST-66 1** | Hybrid/Electric Heat Pump | 60 gal | 82 gal | 3.7 (+0.58) | 1,341 |
| Friedrich PROH65 T0 FD120-MSO | Hybrid/Electric Heat Pump | 59 gal | 63 gal | 3.12 (at parity) | 971 |
What Are the Limitations of Richmond 10E65-HP120MS and Who Should Not Install It?
Before ordering Richmond 10E65-HP120MS (Hybrid/Electric Heat Pump, 3.12 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.
Key Limitations & Exclusions
- Richmond 10E65-HP120MS needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Richmond 10E65-HP120MS directly beside quiet bedrooms.
- Requires condensate drain routing and 120V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Common Homeowner Questions for Richmond 10E65-HP120MS
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Does Richmond 10E65-HP120MS pass the May 6, 2029 federal DOE efficiency rule?
Richmond 10E65-HP120MS carries a verified 3.12 UEF rating (Pass: +0.62 / +24.8%), ranking #654 of 706 across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.
What doorway width and ceiling height does Richmond 10E65-HP120MS need?
Richmond 10E65-HP120MS stands 64.2 in. high with a 24.3 in. diameter; verify 72 in. vertical headroom; clears 28 in. utility doorway (24.3" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.
What gas pipe size or electrical breaker does Richmond 10E65-HP120MS require?
Richmond 10E65-HP120MS uses a 120V branch circuit at 12A max (120V plug-in retrofit circuit; slower heat-pump-only recovery). Verify main breaker space before replacing a gas tank with an electric hybrid unit.
How much electricity or energy does Richmond 10E65-HP120MS cost per year to run?
Rated at 971 kWh/yr, Richmond 10E65-HP120MS costs about $176/yr ($1,760 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $142/yr in Washington hydro tiers up to $458/yr in Hawaii).
Who should NOT install Richmond 10E65-HP120MS, and what are its limits?
Richmond 10E65-HP120MS (3.12 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.
How many bathrooms or people can Richmond 10E65-HP120MS serve at peak demand?
Richmond 10E65-HP120MS achieves a 63 gal First Hour Rating (-9 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.
Are there CPSC safety recalls or serial checks for Richmond 10E65-HP120MS?
No active CPSC recalls matched Richmond as of 2026-11-23. Always decode the serial tag on Richmond 10E65-HP120MS because OEM tank/exchanger warranties span 6–12 years.
What 2026 rebates apply to Richmond 10E65-HP120MS, and what peer compares closest?
Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH65 T0 FD120-M (3.12 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)