Skip to main content
ENERGY STAR water heater model · PD 3555352

Richmond 10E65-HP120MS Water Heater Specifications (3.12 UEF)

Engineered as a Electric Hybrid/Electric Heat Pump unit, Richmond 10E65-HP120MS achieves a certified 3.12 UEF rating across its 59-gallon nominal tank, 63 gal First Hour Rating and ranks #654 of 706 in its 706-model cohort (PD 3555352), recording Pass: +0.62 / +24.8% under 2029 DOE rules. Rated annual electricity draw of 971 kWh/yr equates to roughly $176/yr ($1,763 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH65 T0 FD120-M (3.12 UEF).

Uniform Energy Factor
3.12 UEF
Cohort UEF Rank
#654 of 706
First Hour Rating
63 gal
Storage Volume
59 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +0.62 / +24.8%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Richmond 10E65-HP120MS at 3.12 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50Richmond 10E65-HP120MS: 3.12
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Richmond 10E65-HP120MS relative to the cohort median.
Efficiency comparison & rule summary

Within the 706-unit Hybrid/Electric Heat Pump cohort, Richmond 10E65-HP120MS logs 3.12 UEF and ranks #654 of 706.

Against 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF), Richmond 10E65-HP120MS holds a +0.62 UEF (+24.8%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 971 kWh/yr for Richmond 10E65-HP120MS runs ~$176/yr vs. ~$598/yr for a 0.92 UEF electric tank.

State electric sensitivity for Richmond 10E65-HP120MS: 10-year operating spend spans $1,421 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,581 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Cross-shopping Richmond 10E65-HP120MS (3.12 UEF)? Check Friedrich PROH65 T0 FD120-M (3.12 UEF, at parity) and Rheem PROPH65 T0 RH120-M (3.12 UEF, at parity).

Where Does Richmond 10E65-HP120MS Rank Against Peer Hybrid/Electric Heat Pump Units?

Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, Richmond 10E65-HP120MS holds #654 of 706; inspect footprint, circuit load, and efficiency deltas here.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRichmond80 certified listingsENERGY STAR PD 3555352
Model Number10E65-HP120MSDraw pattern: Medium-Usage10E65-HP120MS
Uniform Energy Factor (UEF)3.12-0.58 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)63 gal-9 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use971 kWh/yr-101 kWh/yr vs. 1,072 kWh/yr medianEst. $176/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency398%-31.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)64.2" H x 24.3" DVerify 72 in. vertical headroom; clears 28 in. utility doorway (24.3" D)Doorway & ceiling check
Electrical Circuit Requirements120 V / 12 A max120V plug-in retrofit circuit; slower heat-pump-only recoveryNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2026-10-15Certified 2026-10-15Markets: United States, Canada

How Much Electricity Does 10E65-HP120MS Use in Different States?

Estimated at $176/yr nationally (971 kWh/yr), 10-year utility spending for Richmond 10E65-HP120MS shifts sharply between low-rate hydro and coastal grids.

Estimated Annual Electricity Cost by State Rate (971 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$176.00/yrHawaii$458.00/yrCalifornia$289.00/yrTexas$154.00/yrWashington$142.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $176/yr $1,763 $4,217
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $458/yr $4,581 $10,955
California 29.75 ¢/kWh ($0.2975) $289/yr $2,889 $6,908
Texas 15.91 ¢/kWh ($0.1591) $154/yr $1,545 $3,694
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $142/yr $1,421 $3,397
Estimated electricity spend (971 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Does CPSC Flag Any Safety Notices on Richmond Units?

No open CPSC recall alerts appeared for Richmond as of 2026-11-23; you can still decode exact manufacture month and warranty window below. See Serial Number Lookup.

Which Competing Hybrid/Electric Heat Pump Models Compare Closest to 10E65-HP120MS?

Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to Richmond 10E65-HP120MS's gallon capacity and 3.12 UEF efficiency.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Friedrich PROH65 T0 FD120-M Hybrid/Electric Heat Pump 59 gal 63 gal 3.12 (at parity) 971
Rheem PROPH65 T0 RH120-M Hybrid/Electric Heat Pump 59 gal 63 gal 3.12 (at parity) 971
Ruud PROUH65 T0 RU120-M Hybrid/Electric Heat Pump 59 gal 63 gal 3.12 (at parity) 971
A. O. Smith HPACO-45 1**+AXST-66 1** Hybrid/Electric Heat Pump 60 gal 82 gal 3.7 (+0.58) 1,341
Friedrich PROH65 T0 FD120-MSO Hybrid/Electric Heat Pump 59 gal 63 gal 3.12 (at parity) 971

What Are the Limitations of Richmond 10E65-HP120MS and Who Should Not Install It?

Before ordering Richmond 10E65-HP120MS (Hybrid/Electric Heat Pump, 3.12 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.

Key Limitations & Exclusions

  • Richmond 10E65-HP120MS needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Richmond 10E65-HP120MS directly beside quiet bedrooms.
  • Requires condensate drain routing and 120V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Richmond 10E65-HP120MS Strong Fit — 3.12 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Friedrich PROH65 T0 FD120-M footprint.

Common Homeowner Questions for Richmond 10E65-HP120MS

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Does Richmond 10E65-HP120MS pass the May 6, 2029 federal DOE efficiency rule?

Richmond 10E65-HP120MS carries a verified 3.12 UEF rating (Pass: +0.62 / +24.8%), ranking #654 of 706 across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.

What doorway width and ceiling height does Richmond 10E65-HP120MS need?

Richmond 10E65-HP120MS stands 64.2 in. high with a 24.3 in. diameter; verify 72 in. vertical headroom; clears 28 in. utility doorway (24.3" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.

What gas pipe size or electrical breaker does Richmond 10E65-HP120MS require?

Richmond 10E65-HP120MS uses a 120V branch circuit at 12A max (120V plug-in retrofit circuit; slower heat-pump-only recovery). Verify main breaker space before replacing a gas tank with an electric hybrid unit.

How much electricity or energy does Richmond 10E65-HP120MS cost per year to run?

Rated at 971 kWh/yr, Richmond 10E65-HP120MS costs about $176/yr ($1,760 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $142/yr in Washington hydro tiers up to $458/yr in Hawaii).

Who should NOT install Richmond 10E65-HP120MS, and what are its limits?

Richmond 10E65-HP120MS (3.12 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.

How many bathrooms or people can Richmond 10E65-HP120MS serve at peak demand?

Richmond 10E65-HP120MS achieves a 63 gal First Hour Rating (-9 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.

Are there CPSC safety recalls or serial checks for Richmond 10E65-HP120MS?

No active CPSC recalls matched Richmond as of 2026-11-23. Always decode the serial tag on Richmond 10E65-HP120MS because OEM tank/exchanger warranties span 6–12 years.

What 2026 rebates apply to Richmond 10E65-HP120MS, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH65 T0 FD120-M (3.12 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks