Skip to main content
ENERGY STAR water heater model · PD 2408936

Richmond 10E65-HP515 Water Heater Specifications (3.55 UEF)

Certified at 3.55 UEF across its 59-gallon nominal tank, 54 gal First Hour Rating, Richmond 10E65-HP515 (Hybrid/Electric Heat Pump, Electric) places #414 of 706 out of 706 ENERGY STAR models (PD 2408936). Its May 6, 2029 10 CFR 430.32 status reads Pass: +1.05 / +42.0%. Rated annual electricity draw of 887 kWh/yr equates to roughly $161/yr ($1,611 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH65 T2 FD400-15 (3.55 UEF).

Uniform Energy Factor
3.55 UEF
Cohort UEF Rank
#414 of 706
First Hour Rating
54 gal
Storage Volume
59 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.05 / +42.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Richmond 10E65-HP515 at 3.55 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50Richmond 10E65-HP515: 3.55
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Richmond 10E65-HP515 relative to the cohort median.
Efficiency comparison & rule summary

Tested at 3.55 UEF, Richmond 10E65-HP515 places #414 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (-0.15 UEF vs. 3.70 UEF median).

Richmond 10E65-HP515 clears 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +1.05 UEF (+42.0% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 887 kWh/yr for Richmond 10E65-HP515 runs ~$161/yr vs. ~$622/yr for a 0.92 UEF electric tank.

State electric sensitivity for Richmond 10E65-HP515: 10-year operating spend spans $1,298 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,185 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Closest alternatives to Richmond 10E65-HP515 include Friedrich PROH65 T2 FD400-15 (3.55 UEF, at parity) alongside Rheem CPROPH65 T2 RH375-15 (3.55 UEF, at parity).

What Physical and Thermal Ratings Define Richmond 10E65-HP515?

Positioning at #414 of 706 out of 706 Hybrid/Electric Heat Pump peers, Richmond 10E65-HP515 pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRichmond80 certified listingsENERGY STAR PD 2408936
Model Number10E65-HP515Draw pattern: Medium-Usage10E65-HP515
Uniform Energy Factor (UEF)3.55-0.15 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)54 gal-18 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use887 kWh/yr-185 kWh/yr vs. 1,072 kWh/yr medianEst. $161/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency407%-22.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)64.2" H x 24.3" DVerify 72 in. vertical headroom; clears 28 in. utility doorway (24.3" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 12 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2026-10-15Certified 2026-10-15Markets: United States

Why Do State Utility Rates Shift 10E65-HP515 Running Costs?

Consuming 887 kWh annually puts Richmond 10E65-HP515 near $161/yr at US baseline tariffs, with multi-state EIA comparisons charted below.

Estimated Annual Electricity Cost by State Rate (887 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$161.00/yrHawaii$418.00/yrCalifornia$264.00/yrTexas$141.00/yrWashington$130.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $161/yr $1,611 $4,605
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $418/yr $4,185 $11,965
California 29.75 ¢/kWh ($0.2975) $264/yr $2,639 $7,545
Texas 15.91 ¢/kWh ($0.1591) $141/yr $1,411 $4,035
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $130/yr $1,298 $3,710
Estimated electricity spend (887 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Have Any Richmond Series Triggered CPSC Recalls?

SaferProducts screening on 2026-11-23 returned zero recall matches for Richmond; confirm tank age separately using the rating-plate serial pattern. See Serial Number Lookup.

What Are 5 Direct Alternatives to Richmond 10E65-HP515?

Homeowners cross-shopping Richmond 10E65-HP515 frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Friedrich PROH65 T2 FD400-15 Hybrid/Electric Heat Pump 59 gal 54 gal 3.55 (at parity) 887
Rheem CPROPH65 T2 RH375-15 Hybrid/Electric Heat Pump 59 gal 54 gal 3.55 (at parity) 887
Ruud PROUH65 T2 CD400-15 Hybrid/Electric Heat Pump 59 gal 54 gal 3.55 (at parity) 887
A. O. Smith HPACO-45 1**+AXST-66 1** Hybrid/Electric Heat Pump 60 gal 82 gal 3.7 (+0.15) 1,341
Rheem CPROPH65 T2 RH400-15 Hybrid/Electric Heat Pump 59 gal 54 gal 3.55 (at parity) 887

What Installation Caveats Apply Before Buying Richmond 10E65-HP515?

Even high-UEF units like Richmond 10E65-HP515 (3.55 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

Key Limitations & Exclusions

  • Richmond 10E65-HP515 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Richmond 10E65-HP515 directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Richmond 10E65-HP515 Strong Fit — 3.55 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Friedrich PROH65 T2 FD400-15 footprint.

Sizing, Efficiency & Recall Answers for Richmond 10E65-HP515

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Is Richmond 10E65-HP515 eligible for continued manufacture past May 6, 2029?

At 3.55 UEF, Richmond 10E65-HP515 achieves Pass: +1.05 / +42.0% for the 2029 DOE standard and stands #414 of 706 against Friedrich PROH65 T2 FD400-15 and Rheem CPROPH65 T2 RH375-15.

How tall and wide is Richmond 10E65-HP515, and what service clearance is needed?

Physical dimensions for Richmond 10E65-HP515 are 64.2 in. height and 24.3 in. diameter (verify 72 in. vertical headroom; clears 28 in. utility doorway (24.3" d)); verify stair turns and drain pan width before delivery.

Will Richmond 10E65-HP515 require upgrading household electrical panels or gas piping?

Richmond 10E65-HP515 draws 240V at 12A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.

Is Richmond 10E65-HP515 economical to operate at 18.16 cents/kWh US electric rates?

Expect roughly $161/yr ($1,610 over 10 years) to power Richmond 10E65-HP515 at 887 kWh/yr under the 18.16 cents/kWh US average (ranging from $130/yr in Washington hydro tiers up to $418/yr in Hawaii).

Which installation bottlenecks limit Richmond 10E65-HP515?

If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, Richmond 10E65-HP515 drops into resistance mode more often.

How does Richmond 10E65-HP515 handle simultaneous showers and laundry?

Delivering 54 gal in the first hour (-18 gal vs. 72 gal median), Richmond 10E65-HP515 combines 59 gal tank storage with rapid burner/element recovery.

How long is the warranty on Richmond 10E65-HP515 and how do you decode its serial?

CPSC records show 0 active plumbing recalls for Richmond as of 2026-11-23. Confirm install proof and serial manufacture year on Richmond 10E65-HP515 before calling service.

How do 2026 post-OBBBA rebates affect buying Richmond 10E65-HP515?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH65 T2 FD400-15 (3.55 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks