Richmond 10E65-HP5U30 Water Heater Specifications (4.05 UEF)
Engineered as a Electric Hybrid/Electric Heat Pump unit, Richmond 10E65-HP5U30 achieves a certified 4.05 UEF rating across its 59-gallon nominal tank, 75 gal First Hour Rating and ranks #61 of 706 in its 706-model cohort (PD 3554217), recording Pass: +1.55 / +62.0% under 2029 DOE rules. Rated annual electricity draw of 1,184 kWh/yr equates to roughly $215/yr ($2,150 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH65 T2 FD400-30 (4.05 UEF).
- Uniform Energy Factor
- 4.05 UEF
- Cohort UEF Rank
- #61 of 706 (top 14.2%)
- First Hour Rating
- 75 gal
- Storage Volume
- 59 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.55 / +62.0%

Within the 706-unit Hybrid/Electric Heat Pump cohort, Richmond 10E65-HP5U30 logs 4.05 UEF and ranks #61 of 706.
Against 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF), Richmond 10E65-HP5U30 holds a +1.55 UEF (+62.0%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 1,184 kWh/yr for Richmond 10E65-HP5U30 runs ~$215/yr vs. ~$946/yr for a 0.92 UEF electric tank.
State electric sensitivity for Richmond 10E65-HP5U30: 10-year operating spend spans $1,732 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,586 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Cross-shopping Richmond 10E65-HP5U30 (4.05 UEF)? Check Friedrich PROH65 T2 FD400-30 (4.05 UEF, at parity) and Rheem CPROPH65 T2 RH375-SO (4.05 UEF, at parity).
Where Does Richmond 10E65-HP5U30 Rank Against Peer Hybrid/Electric Heat Pump Units?
Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, Richmond 10E65-HP5U30 holds #61 of 706 (top 14.2%); inspect footprint, circuit load, and efficiency deltas here.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Richmond | 80 certified listings | ENERGY STAR PD 3554217 |
| Model Number | 10E65-HP5U30 | Draw pattern: High-Usage | 10E65-HP5U30 |
| Uniform Energy Factor (UEF) | 4.05 | +0.35 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 75 gal | +3 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,184 kWh/yr | +112 kWh/yr vs. 1,072 kWh/yr median | Est. $215/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 457% | +28.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 64.2" H x 24.3" D | Verify 72 in. vertical headroom; clears 28 in. utility doorway (24.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-15 | Certified 2026-10-15 | Markets: United States |
How Much Electricity Does 10E65-HP5U30 Use in Different States?
Estimated at $215/yr nationally (1,184 kWh/yr), 10-year utility spending for Richmond 10E65-HP5U30 shifts sharply between low-rate hydro and coastal grids.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $215/yr | $2,150 | $7,315 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $559/yr | $5,586 | $19,004 |
| California | 29.75 ¢/kWh ($0.2975) | $352/yr | $3,522 | $11,983 |
| Texas | 15.91 ¢/kWh ($0.1591) | $188/yr | $1,884 | $6,409 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $173/yr | $1,732 | $5,893 |
Does CPSC Flag Any Safety Notices on Richmond Units?
No open CPSC recall alerts appeared for Richmond as of 2026-11-23; you can still decode exact manufacture month and warranty window below. See Serial Number Lookup.
Which Competing Hybrid/Electric Heat Pump Models Compare Closest to 10E65-HP5U30?
Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to Richmond 10E65-HP5U30's gallon capacity and 4.05 UEF efficiency.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Friedrich PROH65 T2 FD400-30 | Hybrid/Electric Heat Pump | 59 gal | 75 gal | 4.05 (at parity) | 1,184 |
| Rheem CPROPH65 T2 RH375-SO | Hybrid/Electric Heat Pump | 59 gal | 75 gal | 4.05 (at parity) | 1,184 |
| Ruud CPROPH65 T2 CD375-30 | Hybrid/Electric Heat Pump | 59 gal | 75 gal | 4.05 (at parity) | 1,213 |
| Bosch TR7000T-65CA | Hybrid/Electric Heat Pump | 60 gal | 80 gal | 3.9 (-0.15) | 1,240 |
| Friedrich PROH65 T2 FD400-SO | Hybrid/Electric Heat Pump | 59 gal | 75 gal | 4.05 (at parity) | 1,184 |
Which Home Setups Are NOT a Fit for Richmond 10E65-HP5U30?
Comparing Richmond 10E65-HP5U30 against Friedrich PROH65 T2 FD400-30 requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.
Key Limitations & Exclusions
- Richmond 10E65-HP5U30 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Richmond 10E65-HP5U30 directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Common Homeowner Questions for Richmond 10E65-HP5U30
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
How does Richmond 10E65-HP5U30 score under 10 CFR 430.32 May 2029 water heater minimums?
Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; Richmond 10E65-HP5U30 logs 4.05 UEF (Pass: +1.55 / +62.0%) within the 706-unit Hybrid/Electric Heat Pump group.
What physical clearance dimensions apply when installing Richmond 10E65-HP5U30?
With a 64.2 in. height and 24.3 in. diameter, Richmond 10E65-HP5U30 fits spaces matching: verify 72 in. vertical headroom; clears 28 in. utility doorway (24.3" d), plus 6–12 in. above for plumbing shutoffs.
What 240V circuit or IFGC fuel line capacity fits Richmond 10E65-HP5U30?
Powered via 240V at 21A max, Richmond 10E65-HP5U30 requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.
How do state electricity prices change annual costs for Richmond 10E65-HP5U30?
Annual electric spend for Richmond 10E65-HP5U30 (1,184 kWh/yr) averages $215/yr nationwide (ranging from $173/yr in Washington hydro tiers up to $559/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.
What homeowner setups should avoid choosing Richmond 10E65-HP5U30?
Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on Richmond 10E65-HP5U30.
Is Richmond 10E65-HP5U30 sized adequately for a 2-to-4-person household?
ENERGY STAR certifies Richmond 10E65-HP5U30 at 75 gal First Hour Rating (+3 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.
Does Richmond have active CPSC SaferProducts notices affecting 10E65-HP5U30?
Zero CPSC recall alerts matched Richmond (2026-11-23 check). Keep your Richmond 10E65-HP5U30 serial code handy to track standard 6-to-12-year OEM warranty coverage.
Which competing water heater matches Richmond 10E65-HP5U30 (4.05 UEF) most closely?
State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for Richmond 10E65-HP5U30. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH65 T2 FD400-30 (4.05 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)