Richmond 10E65-HP5US30 Water Heater Specifications (4.05 UEF)
Certified at 4.05 UEF across its 59-gallon nominal tank, 75 gal First Hour Rating, Richmond 10E65-HP5US30 (Hybrid/Electric Heat Pump, Electric) places #61 of 706 out of 706 ENERGY STAR models (PD 3554221). Its May 6, 2029 10 CFR 430.32 status reads Pass: +1.55 / +62.0%. Rated annual electricity draw of 1,184 kWh/yr equates to roughly $215/yr ($2,150 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH65 T2 FD400-30 (4.05 UEF).
- Uniform Energy Factor
- 4.05 UEF
- Cohort UEF Rank
- #61 of 706 (top 14.2%)
- First Hour Rating
- 75 gal
- Storage Volume
- 59 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.55 / +62.0%

Tested at 4.05 UEF, Richmond 10E65-HP5US30 places #61 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (+0.35 UEF vs. 3.70 UEF median).
Richmond 10E65-HP5US30 clears 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +1.55 UEF (+62.0% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 1,184 kWh/yr for Richmond 10E65-HP5US30 runs ~$215/yr vs. ~$946/yr for a 0.92 UEF electric tank.
State electric sensitivity for Richmond 10E65-HP5US30: 10-year operating spend spans $1,732 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,586 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Closest alternatives to Richmond 10E65-HP5US30 include Friedrich PROH65 T2 FD400-30 (4.05 UEF, at parity) alongside Rheem CPROPH65 T2 RH375-SO (4.05 UEF, at parity).
What Physical and Thermal Ratings Define Richmond 10E65-HP5US30?
Positioning at #61 of 706 (top 14.2%) out of 706 Hybrid/Electric Heat Pump peers, Richmond 10E65-HP5US30 pairs measured UEF performance with specific clearance and wiring rules.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Richmond | 80 certified listings | ENERGY STAR PD 3554221 |
| Model Number | 10E65-HP5US30 | Draw pattern: High-Usage | 10E65-HP5US30 |
| Uniform Energy Factor (UEF) | 4.05 | +0.35 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 75 gal | +3 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,184 kWh/yr | +112 kWh/yr vs. 1,072 kWh/yr median | Est. $215/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 457% | +28.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 64.2" H x 24.3" D | Verify 72 in. vertical headroom; clears 28 in. utility doorway (24.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-15 | Certified 2026-10-15 | Markets: United States |
Why Do State Utility Rates Shift 10E65-HP5US30 Running Costs?
Consuming 1,184 kWh annually puts Richmond 10E65-HP5US30 near $215/yr at US baseline tariffs, with multi-state EIA comparisons charted below.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $215/yr | $2,150 | $7,315 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $559/yr | $5,586 | $19,004 |
| California | 29.75 ¢/kWh ($0.2975) | $352/yr | $3,522 | $11,983 |
| Texas | 15.91 ¢/kWh ($0.1591) | $188/yr | $1,884 | $6,409 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $173/yr | $1,732 | $5,893 |
Have Any Richmond Series Triggered CPSC Recalls?
SaferProducts screening on 2026-11-23 returned zero recall matches for Richmond; confirm tank age separately using the rating-plate serial pattern. See Serial Number Lookup.
What Are 5 Direct Alternatives to Richmond 10E65-HP5US30?
Homeowners cross-shopping Richmond 10E65-HP5US30 frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Friedrich PROH65 T2 FD400-30 | Hybrid/Electric Heat Pump | 59 gal | 75 gal | 4.05 (at parity) | 1,184 |
| Rheem CPROPH65 T2 RH375-SO | Hybrid/Electric Heat Pump | 59 gal | 75 gal | 4.05 (at parity) | 1,184 |
| Ruud CPROPH65 T2 CD375-30 | Hybrid/Electric Heat Pump | 59 gal | 75 gal | 4.05 (at parity) | 1,213 |
| Bosch TR7000T-65CA | Hybrid/Electric Heat Pump | 60 gal | 80 gal | 3.9 (-0.15) | 1,240 |
| Friedrich PROH65 T2 FD400-SO | Hybrid/Electric Heat Pump | 59 gal | 75 gal | 4.05 (at parity) | 1,184 |
When Should Homeowners Skip Richmond 10E65-HP5US30 (Hybrid/Electric Heat Pump)?
Check Richmond 10E65-HP5US30's mechanical constraints—including utility space, Electric capacity, and Pass: +1.55 / +62.0% status—against typical residential installations.
Key Limitations & Exclusions
- Richmond 10E65-HP5US30 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Richmond 10E65-HP5US30 directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Sizing, Efficiency & Recall Answers for Richmond 10E65-HP5US30
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Will Richmond 10E65-HP5US30 stay compliant after the May 6, 2029 DOE standard takes effect?
Tested at 4.05 UEF, Richmond 10E65-HP5US30 shows Pass: +1.55 / +62.0% relative to May 6, 2029 federal DOE limits while placing #61 of 706 (top 14.2%) among 706 Hybrid/Electric Heat Pump peers like Friedrich PROH65 T2 FD400-30.
Will Richmond 10E65-HP5US30 fit through a standard utility door and 72-inch basement ceiling?
Measuring 64.2 in. tall by 24.3 in. diameter, Richmond 10E65-HP5US30 notes: verify 72 in. vertical headroom; clears 28 in. utility doorway (24.3" d). Reserve space above the jacket for T&P piping and anode removal.
Do existing utility hookups support Richmond 10E65-HP5US30 during replacement?
Electrical specs for Richmond 10E65-HP5US30 call for 240V at 21A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.
What is the estimated 10-year operating spend for Richmond 10E65-HP5US30?
At 18.16 cents/kWh national residential pricing, Richmond 10E65-HP5US30's 1,184 kWh/yr draw equals roughly $215 annually or $2,150 across a 10-year horizon (ranging from $173/yr in Washington hydro tiers up to $559/yr in Hawaii).
When is Richmond 10E65-HP5US30 a poor fit for a residential replacement?
Avoid placing Richmond 10E65-HP5US30 directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.
What First Hour Rating or flow capacity does Richmond 10E65-HP5US30 deliver?
With 75 gal FHR (+3 gal vs. 72 gal median), Richmond 10E65-HP5US30 fits larger 3–5 person homes cleanly.
How do you verify manufacturing age and recall status on Richmond 10E65-HP5US30?
Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for Richmond; verify exact manufacturing week for Richmond 10E65-HP5US30 using the Serial Number Lookup tool.
Does Richmond 10E65-HP5US30 qualify for DOE HEAR incentives after 25C expired?
After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Richmond 10E65-HP5US30. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH65 T2 FD400-30 (4.05 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)