Skip to main content
ENERGY STAR water heater model · PD 4692185

Richmond 10E65-HP5UZ30 Water Heater Specifications (4.05 UEF)

The Richmond 10E65-HP5UZ30 (Hybrid/Electric Heat Pump, Electric) achieves a certified 4.05 UEF rating across its 59-gallon nominal tank, 75 gal First Hour Rating, ranking #61 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 4692185). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +1.55 / +62.0%. Rated annual electricity draw of 1,184 kWh/yr equates to roughly $215/yr ($2,150 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH65 T2 FD400-30 (4.05 UEF).

Uniform Energy Factor
4.05 UEF
Cohort UEF Rank
#61 of 706 (top 14.2%)
First Hour Rating
75 gal
Storage Volume
59 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.55 / +62.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Richmond 10E65-HP5UZ30 at 4.05 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50Richmond 10E65-HP5UZ30: 4.05
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Richmond 10E65-HP5UZ30 relative to the cohort median.
Efficiency comparison & rule summary

Richmond 10E65-HP5UZ30 (4.05 UEF) ranks #61 of 706 Hybrid/Electric Heat Pump models — 40-way tie; top 14.2%, more efficient than 85.8% of Hybrid/Electric Heat Pump models, +0.35 UEF above the 3.70 UEF median.

Federal 2029 margin for Richmond 10E65-HP5UZ30: +1.55 UEF (+62.0%) vs. 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,184 kWh/yr for Richmond 10E65-HP5UZ30 runs ~$215/yr vs. ~$946/yr for a 0.92 UEF electric tank.

State electric sensitivity for Richmond 10E65-HP5UZ30: 10-year operating spend spans $1,732 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,586 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Peer comparison: Richmond 10E65-HP5UZ30 (4.05 UEF) compares closely with Friedrich PROH65 T2 FD400-30 (4.05 UEF, at parity) and Rheem CPROPH65 T2 RH375-SO (4.05 UEF, at parity).

Which Specs Set Richmond 10E65-HP5UZ30 Apart From Cohort Averages?

Ranked #61 of 706 (top 14.2%) inside the 706-model Hybrid/Electric Heat Pump cohort, Richmond 10E65-HP5UZ30 is evaluated row by row below against category medians.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRichmond80 certified listingsENERGY STAR PD 4692185
Model Number10E65-HP5UZ30Draw pattern: High-Usage10E65-HP5UZ30
Uniform Energy Factor (UEF)4.05+0.35 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)75 gal+3 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,184 kWh/yr+112 kWh/yr vs. 1,072 kWh/yr medianEst. $215/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency457%+28.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)64.2" H x 24.3" DVerify 72 in. vertical headroom; clears 28 in. utility doorway (24.3" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 21 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-1234YFLower-GWP refrigerant alignment (EPA AIM Act)EPA AIM Act Compliance
Certification Date2026-10-15Certified 2026-10-15Markets: United States

How Do Regional kWh Prices Impact 10E65-HP5UZ30 Over 10 Years?

Using EIA Table 5.6.A benchmarks, Richmond 10E65-HP5UZ30's 1,184 kWh/yr draw translates to roughly $215/yr on typical US residential bills.

Estimated Annual Electricity Cost by State Rate (1,184 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$215.00/yrHawaii$559.00/yrCalifornia$352.00/yrTexas$188.00/yrWashington$173.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $215/yr $2,150 $7,315
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $559/yr $5,586 $19,004
California 29.75 ¢/kWh ($0.2975) $352/yr $3,522 $11,983
Texas 15.91 ¢/kWh ($0.1591) $188/yr $1,884 $6,409
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $173/yr $1,732 $5,893
Estimated electricity spend (1,184 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

What Should Richmond Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC recall sweep recorded zero brand matches for Richmond; run a quick serial-number check to verify age before replacing wear parts. See Serial Number Lookup.

How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?

Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Friedrich PROH65 T2 FD400-30 Hybrid/Electric Heat Pump 59 gal 75 gal 4.05 (at parity) 1,184
Rheem CPROPH65 T2 RH375-SO Hybrid/Electric Heat Pump 59 gal 75 gal 4.05 (at parity) 1,184
Ruud CPROPH65 T2 CD375-30 Hybrid/Electric Heat Pump 59 gal 75 gal 4.05 (at parity) 1,213
Bosch TR7000T-65CA Hybrid/Electric Heat Pump 60 gal 80 gal 3.9 (-0.15) 1,240
Friedrich PROH65 T2 FD400-SO Hybrid/Electric Heat Pump 59 gal 75 gal 4.05 (at parity) 1,184

Which Home Setups Are NOT a Fit for Richmond 10E65-HP5UZ30?

Comparing Richmond 10E65-HP5UZ30 against Friedrich PROH65 T2 FD400-30 requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

Key Limitations & Exclusions

  • Richmond 10E65-HP5UZ30 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Richmond 10E65-HP5UZ30 directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Richmond 10E65-HP5UZ30 Strong Fit — 4.05 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Friedrich PROH65 T2 FD400-30 footprint.

Frequently Asked Technical Questions: Richmond 10E65-HP5UZ30

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does Richmond 10E65-HP5UZ30 score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; Richmond 10E65-HP5UZ30 logs 4.05 UEF (Pass: +1.55 / +62.0%) within the 706-unit Hybrid/Electric Heat Pump group.

What physical clearance dimensions apply when installing Richmond 10E65-HP5UZ30?

With a 64.2 in. height and 24.3 in. diameter, Richmond 10E65-HP5UZ30 fits spaces matching: verify 72 in. vertical headroom; clears 28 in. utility doorway (24.3" d), plus 6–12 in. above for plumbing shutoffs.

What 240V circuit or IFGC fuel line capacity fits Richmond 10E65-HP5UZ30?

Powered via 240V at 21A max, Richmond 10E65-HP5UZ30 requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.

How do state electricity prices change annual costs for Richmond 10E65-HP5UZ30?

Annual electric spend for Richmond 10E65-HP5UZ30 (1,184 kWh/yr) averages $215/yr nationwide (ranging from $173/yr in Washington hydro tiers up to $559/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.

What homeowner setups should avoid choosing Richmond 10E65-HP5UZ30?

Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on Richmond 10E65-HP5UZ30.

Is Richmond 10E65-HP5UZ30 sized adequately for a 2-to-4-person household?

ENERGY STAR certifies Richmond 10E65-HP5UZ30 at 75 gal First Hour Rating (+3 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.

Does Richmond have active CPSC SaferProducts notices affecting 10E65-HP5UZ30?

Zero CPSC recall alerts matched Richmond (2026-11-23 check). Keep your Richmond 10E65-HP5UZ30 serial code handy to track standard 6-to-12-year OEM warranty coverage.

Which competing water heater matches Richmond 10E65-HP5UZ30 (4.05 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for Richmond 10E65-HP5UZ30. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH65 T2 FD400-30 (4.05 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks