Skip to main content
ENERGY STAR water heater model · PD 3554213

Richmond XE65T10H22U1 Water Heater Specifications (3.55 UEF)

With PD 3554213 certification, Richmond XE65T10H22U1 (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.55 UEF rating across its 59-gallon nominal tank, 54 gal First Hour Rating, standing #414 of 706 across 706 peers with Pass: +1.05 / +42.0% for May 6, 2029. Rated annual electricity draw of 887 kWh/yr equates to roughly $161/yr ($1,611 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH65 T2 FD400-15 (3.55 UEF).

Uniform Energy Factor
3.55 UEF
Cohort UEF Rank
#414 of 706
First Hour Rating
54 gal
Storage Volume
59 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.05 / +42.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Richmond XE65T10H22U1 at 3.55 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50Richmond XE65T10H22U1: 3.55
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Richmond XE65T10H22U1 relative to the cohort median.
Efficiency comparison & rule summary

ENERGY STAR certification places Richmond XE65T10H22U1 at 3.55 UEF (#414 of 706; -0.15 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.

May 6, 2029 readiness: Richmond XE65T10H22U1 stands +1.05 UEF (+42.0%) relative to 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 887 kWh/yr for Richmond XE65T10H22U1 runs ~$161/yr vs. ~$622/yr for a 0.92 UEF electric tank.

State electric sensitivity for Richmond XE65T10H22U1: 10-year operating spend spans $1,298 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,185 in Hawaii (Highest EIA State) (47.18 cents/kWh).

In the Hybrid/Electric Heat Pump tier, Friedrich PROH65 T2 FD400-15 (3.55 UEF, at parity) and Rheem CPROPH65 T2 RH375-15 (3.55 UEF, at parity) bracket Richmond XE65T10H22U1.

What Physical and Thermal Ratings Define Richmond XE65T10H22U1?

Positioning at #414 of 706 out of 706 Hybrid/Electric Heat Pump peers, Richmond XE65T10H22U1 pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRichmond80 certified listingsENERGY STAR PD 3554213
Model NumberXE65T10H22U1Draw pattern: Medium-UsageXE65T10H22U1
Uniform Energy Factor (UEF)3.55-0.15 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)54 gal-18 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use887 kWh/yr-185 kWh/yr vs. 1,072 kWh/yr medianEst. $161/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency407%-22.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)64.2" H x 24.3" DVerify 72 in. vertical headroom; clears 28 in. utility doorway (24.3" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 12 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2026-10-15Certified 2026-10-15Markets: United States

Why Do State Utility Rates Shift XE65T10H22U1 Running Costs?

Consuming 887 kWh annually puts Richmond XE65T10H22U1 near $161/yr at US baseline tariffs, with multi-state EIA comparisons charted below.

Estimated Annual Electricity Cost by State Rate (887 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$161.00/yrHawaii$418.00/yrCalifornia$264.00/yrTexas$141.00/yrWashington$130.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $161/yr $1,611 $4,605
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $418/yr $4,185 $11,965
California 29.75 ¢/kWh ($0.2975) $264/yr $2,639 $7,545
Texas 15.91 ¢/kWh ($0.1591) $141/yr $1,411 $4,035
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $130/yr $1,298 $3,710
Estimated electricity spend (887 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Have Any Richmond Series Triggered CPSC Recalls?

SaferProducts screening on 2026-11-23 returned zero recall matches for Richmond; confirm tank age separately using the rating-plate serial pattern. See Serial Number Lookup.

What Are 5 Direct Alternatives to Richmond XE65T10H22U1?

Homeowners cross-shopping Richmond XE65T10H22U1 frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Friedrich PROH65 T2 FD400-15 Hybrid/Electric Heat Pump 59 gal 54 gal 3.55 (at parity) 887
Rheem CPROPH65 T2 RH375-15 Hybrid/Electric Heat Pump 59 gal 54 gal 3.55 (at parity) 887
Ruud PROUH65 T2 CD400-15 Hybrid/Electric Heat Pump 59 gal 54 gal 3.55 (at parity) 887
A. O. Smith HPACO-45 1**+AXST-66 1** Hybrid/Electric Heat Pump 60 gal 82 gal 3.7 (+0.15) 1,341
Rheem CPROPH65 T2 RH400-15 Hybrid/Electric Heat Pump 59 gal 54 gal 3.55 (at parity) 887

What Are the Limitations of Richmond XE65T10H22U1 and Who Should Not Install It?

Before ordering Richmond XE65T10H22U1 (Hybrid/Electric Heat Pump, 3.55 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.

Key Limitations & Exclusions

  • Richmond XE65T10H22U1 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Richmond XE65T10H22U1 directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Richmond XE65T10H22U1 Strong Fit — 3.55 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Friedrich PROH65 T2 FD400-15 footprint.

Sizing, Efficiency & Recall Answers for Richmond XE65T10H22U1

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Does Richmond XE65T10H22U1 pass the May 6, 2029 federal DOE efficiency rule?

Richmond XE65T10H22U1 carries a verified 3.55 UEF rating (Pass: +1.05 / +42.0%), ranking #414 of 706 across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.

What doorway width and ceiling height does Richmond XE65T10H22U1 need?

Richmond XE65T10H22U1 stands 64.2 in. high with a 24.3 in. diameter; verify 72 in. vertical headroom; clears 28 in. utility doorway (24.3" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.

What gas pipe size or electrical breaker does Richmond XE65T10H22U1 require?

Richmond XE65T10H22U1 uses a 240V branch circuit at 12A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.

How much electricity or energy does Richmond XE65T10H22U1 cost per year to run?

Rated at 887 kWh/yr, Richmond XE65T10H22U1 costs about $161/yr ($1,610 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $130/yr in Washington hydro tiers up to $418/yr in Hawaii).

Who should NOT install Richmond XE65T10H22U1, and what are its limits?

Richmond XE65T10H22U1 (3.55 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.

How many bathrooms or people can Richmond XE65T10H22U1 serve at peak demand?

Richmond XE65T10H22U1 achieves a 54 gal First Hour Rating (-18 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.

Are there CPSC safety recalls or serial checks for Richmond XE65T10H22U1?

No active CPSC recalls matched Richmond as of 2026-11-23. Always decode the serial tag on Richmond XE65T10H22U1 because OEM tank/exchanger warranties span 6–12 years.

What 2026 rebates apply to Richmond XE65T10H22U1, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH65 T2 FD400-15 (3.55 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks