Rinnai REHP80W Water Heater Specifications (4 UEF)
The Rinnai REHP80W (Hybrid/Electric Heat Pump, Electric) achieves a certified 4.0 UEF rating across its 75-gallon nominal tank, 91 gal First Hour Rating, ranking #106 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 4682175). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +1.50 / +60.0%. Rated annual electricity draw of 1,230 kWh/yr equates to roughly $223/yr ($2,234 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Midea CAN3-RSJ-15/300RDVN3-L4 (4.0 UEF).
- Uniform Energy Factor
- 4.0 UEF
- Cohort UEF Rank
- #106 of 706 (top 19.8%)
- First Hour Rating
- 91 gal
- Storage Volume
- 75 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.50 / +60.0%

Rinnai REHP80W (4.0 UEF) ranks #106 of 706 Hybrid/Electric Heat Pump models — 35-way tie; top 19.8%, more efficient than 80.2% of Hybrid/Electric Heat Pump models, +0.30 UEF above the 3.70 UEF median.
Federal 2029 margin for Rinnai REHP80W: +1.50 UEF (+60.0%) vs. 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,230 kWh/yr for Rinnai REHP80W runs ~$223/yr vs. ~$971/yr for a 0.92 UEF electric tank. Acoustic output is 49 dBA (quieter than 12.8% of Hybrid/Electric Heat Pump models).
State electric sensitivity for Rinnai REHP80W: 10-year operating spend spans $1,799 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,803 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Peer comparison: Rinnai REHP80W (4.0 UEF) compares closely with Midea CAN3-RSJ-15/300RDVN3-L4 (4.0 UEF, at parity) and Bradford White RE2HP80**-1NCTT (4.0 UEF, at parity).
Where Does Rinnai REHP80W Rank Against Peer Hybrid/Electric Heat Pump Units?
Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, Rinnai REHP80W holds #106 of 706 (top 19.8%); inspect footprint, circuit load, and efficiency deltas here.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Rinnai | 25 certified listings | ENERGY STAR PD 4682175 |
| Model Number | REHP80W | Draw pattern: High-Usage | REHP80W |
| Uniform Energy Factor (UEF) | 4.0 | +0.30 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 91 gal | +19 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,230 kWh/yr | +158 kWh/yr vs. 1,072 kWh/yr median | Est. $223/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 450% | +21.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 41.7" H x 21.8" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 24 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Sound Pressure Level | 49 dBA | quieter than 12.8% of Hybrid/Electric Heat Pump models · At 49 dBA median | Indoor placement check |
| Certification Date | 2026-07-31 | Certified 2026-07-31 | Markets: United States, Canada |
How Much Electricity Does REHP80W Use in Different States?
Estimated at $223/yr nationally (1,230 kWh/yr), 10-year utility spending for Rinnai REHP80W shifts sharply between low-rate hydro and coastal grids.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $223/yr | $2,234 | $7,478 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $580/yr | $5,803 | $19,429 |
| California | 29.75 ¢/kWh ($0.2975) | $366/yr | $3,659 | $12,251 |
| Texas | 15.91 ¢/kWh ($0.1591) | $196/yr | $1,957 | $6,552 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $180/yr | $1,799 | $6,025 |
Does CPSC Flag Any Safety Notices on Rinnai Units?
No open CPSC recall alerts appeared for Rinnai as of 2026-11-23; you can still decode exact manufacture month and warranty window below. See Serial Number Lookup.
Which Competing Hybrid/Electric Heat Pump Models Compare Closest to REHP80W?
Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to Rinnai REHP80W's gallon capacity and 4.0 UEF efficiency.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Midea CAN3-RSJ-15/300RDVN3-L4 | Hybrid/Electric Heat Pump | 75 gal | 91 gal | 4.0 (at parity) | 1,230 |
| Bradford White RE2HP80**-1NCTT | Hybrid/Electric Heat Pump | 75 gal | 88 gal | 4.0 (at parity) | 1,240 |
| JETGLAS RE2HP80*-1NCTT | Hybrid/Electric Heat Pump | 75 gal | 88 gal | 4.0 (at parity) | 1,240 |
| 1HVAC ACIQ-80G-HP-WH | Hybrid/Electric Heat Pump | 74 gal | 91 gal | 4.0 (at parity) | 1,240 |
| Midea MAHW-80VN3B | Hybrid/Electric Heat Pump | 75 gal | 91 gal | 4.0 (at parity) | 1,230 |
What Are the Limitations of Rinnai REHP80W and Who Should Not Install It?
Before ordering Rinnai REHP80W (Hybrid/Electric Heat Pump, 4.0 UEF), weigh space clearances, fuel piping, noise (49 dBA), and 2029 rule readiness across three scenarios.
Key Limitations & Exclusions
- Rinnai REHP80W needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Rinnai REHP80W directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Common Homeowner Questions for Rinnai REHP80W
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Does Rinnai REHP80W pass the May 6, 2029 federal DOE efficiency rule?
Rinnai REHP80W carries a verified 4.0 UEF rating (Pass: +1.50 / +60.0%), ranking #106 of 706 (top 19.8%) across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.
What doorway width and ceiling height does Rinnai REHP80W need?
Rinnai REHP80W stands 41.7 in. high with a 21.8 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.
What gas pipe size or electrical breaker does Rinnai REHP80W require?
Rinnai REHP80W uses a 240V branch circuit at 24A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.
How much electricity or energy does Rinnai REHP80W cost per year to run?
Rated at 1,230 kWh/yr, Rinnai REHP80W costs about $223/yr ($2,230 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $180/yr in Washington hydro tiers up to $580/yr in Hawaii).
Who should NOT install Rinnai REHP80W, and what are its limits?
Rinnai REHP80W (4.0 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.
How many bathrooms or people can Rinnai REHP80W serve at peak demand?
Rinnai REHP80W achieves a 91 gal First Hour Rating (+19 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.
Are there CPSC safety recalls or serial checks for Rinnai REHP80W?
No active CPSC recalls matched Rinnai as of 2026-11-23. Always decode the serial tag on Rinnai REHP80W because OEM tank/exchanger warranties span 6–12 years.
What 2026 rebates apply to Rinnai REHP80W, and what peer compares closest?
Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is Midea CAN3-RSJ-15/300RDVN3-L4 (4.0 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)