Skip to main content
ENERGY STAR water heater model · PD 4572771

Ruud PROUH50 T2 CD400-SO Water Heater Specifications (3.88 UEF)

Certified at 3.88 UEF across its 45-gallon nominal tank, 67 gal First Hour Rating, Ruud PROUH50 T2 CD400-SO (Hybrid/Electric Heat Pump, Electric) places #165 of 706 out of 706 ENERGY STAR models (PD 4572771). Its May 6, 2029 10 CFR 430.32 status reads Pass: +1.58 / +68.7%. Rated annual electricity draw of 846 kWh/yr equates to roughly $154/yr ($1,536 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH50 T2 FD400-30 (3.88 UEF).

Uniform Energy Factor
3.88 UEF
Cohort UEF Rank
#165 of 706 (top 30.6%)
First Hour Rating
67 gal
Storage Volume
45 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.58 / +68.7%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Ruud PROUH50 T2 CD400-SO at 3.88 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30Ruud PROUH50 T2 CD400-SO: 3.88
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Ruud PROUH50 T2 CD400-SO relative to the cohort median.
Efficiency comparison & rule summary

Tested at 3.88 UEF, Ruud PROUH50 T2 CD400-SO places #165 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (+0.18 UEF vs. 3.70 UEF median).

Ruud PROUH50 T2 CD400-SO clears 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.58 UEF (+68.7% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 846 kWh/yr for Ruud PROUH50 T2 CD400-SO runs ~$154/yr vs. ~$648/yr for a 0.92 UEF electric tank.

State electric sensitivity for Ruud PROUH50 T2 CD400-SO: 10-year operating spend spans $1,238 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $3,991 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Closest alternatives to Ruud PROUH50 T2 CD400-SO include Friedrich PROH50 T2 FD400-30 (3.88 UEF, at parity) alongside Rheem CPROPH50 T2 RH375-SO (3.88 UEF, at parity).

What Physical and Thermal Ratings Define Ruud PROUH50 T2 CD400-SO?

Positioning at #165 of 706 (top 30.6%) out of 706 Hybrid/Electric Heat Pump peers, Ruud PROUH50 T2 CD400-SO pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRuud95 certified listingsENERGY STAR PD 4572771
Model NumberPROUH50 T2 CD400-SODraw pattern: Medium-UsagePROUH50 T2 CD400-SO
Uniform Energy Factor (UEF)3.88+0.18 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)67 gal-5 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use846 kWh/yr-226 kWh/yr vs. 1,072 kWh/yr medianEst. $154/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency430%+1.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)61.8" H x 22.3" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.3" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 21 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2026-10-22Certified 2026-10-22Markets: Canada

Why Do State Utility Rates Shift PROUH50 T2 CD400-SO Running Costs?

Consuming 846 kWh annually puts Ruud PROUH50 T2 CD400-SO near $154/yr at US baseline tariffs, with multi-state EIA comparisons charted below.

Estimated Annual Electricity Cost by State Rate (846 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$154.00/yrHawaii$399.00/yrCalifornia$252.00/yrTexas$135.00/yrWashington$124.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $154/yr $1,536 $4,943
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $399/yr $3,991 $12,842
California 29.75 ¢/kWh ($0.2975) $252/yr $2,517 $8,098
Texas 15.91 ¢/kWh ($0.1591) $135/yr $1,346 $4,331
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $124/yr $1,238 $3,982
Estimated electricity spend (846 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Have Any Ruud Series Triggered CPSC Recalls?

SaferProducts records retrieved 2026-11-23 list 2 brand notices under Ruud; inspect model coverage dates prior to valve or anode service. See Serial Number Lookup.

2 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #07108 (2007-02-21): Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard (CPSC Notice)
  • Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)

What Are 5 Direct Alternatives to Ruud PROUH50 T2 CD400-SO?

Homeowners cross-shopping Ruud PROUH50 T2 CD400-SO frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Friedrich PROH50 T2 FD400-30 Hybrid/Electric Heat Pump 45 gal 67 gal 3.88 (at parity) 846
Rheem CPROPH50 T2 RH375-SO Hybrid/Electric Heat Pump 45 gal 67 gal 3.88 (at parity) 846
Richmond 10CE50-HP5S30 Hybrid/Electric Heat Pump 45 gal 67 gal 3.88 (at parity) 846
Bradford White RE2HP50**-1NCTT Hybrid/Electric Heat Pump 45 gal 65 gal 3.89 (+0.01) 835
Friedrich PROH50 T2 FD400-SO Hybrid/Electric Heat Pump 45 gal 67 gal 3.88 (at parity) 846

Who Is Ruud PROUH50 T2 CD400-SO Best For — and When Should You Pick Friedrich PROH50 T2 FD400-30?

Evaluate whether Ruud PROUH50 T2 CD400-SO's Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.

Key Limitations & Exclusions

  • Ruud PROUH50 T2 CD400-SO needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Ruud PROUH50 T2 CD400-SO directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Ruud PROUH50 T2 CD400-SO Strong Fit — 3.88 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Friedrich PROH50 T2 FD400-30 footprint.

Sizing, Efficiency & Recall Answers for Ruud PROUH50 T2 CD400-SO

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does Ruud PROUH50 T2 CD400-SO (3.88 UEF) compare to 2029 federal DOE floors?

Evaluated against May 6, 2029 10 CFR 430.32 thresholds, Ruud PROUH50 T2 CD400-SO records 3.88 UEF (Pass: +1.58 / +68.7%), placing #165 of 706 (top 30.6%) out of 706 certified Hybrid/Electric Heat Pump configurations.

Does Ruud PROUH50 T2 CD400-SO fit inside a tight hallway closet or low-headroom utility room?

Ruud PROUH50 T2 CD400-SO requires room for its 61.8 in. vertical shell and 22.3 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.3" d)), plus service access for annual sediment draining.

What power supply or fuel line specs govern Ruud PROUH50 T2 CD400-SO?

For Ruud PROUH50 T2 CD400-SO, plan a 240V circuit at 21A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.

What annual utility bill should homeowners budget for Ruud PROUH50 T2 CD400-SO?

Using 846 kWh/yr, Ruud PROUH50 T2 CD400-SO generates an estimated $154/yr electric bill at 18.16 cents/kWh (ranging from $124/yr in Washington hydro tiers up to $399/yr in Hawaii)—use the custom rate slider above for your utility tariff.

What are the main drawbacks of Ruud PROUH50 T2 CD400-SO (3.88 UEF)?

Ruud PROUH50 T2 CD400-SO requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or Friedrich PROH50 T2 FD400-30.

What hot-water delivery rating governs Ruud PROUH50 T2 CD400-SO?

Rated for 67 gal FHR (-5 gal vs. 72 gal median), Ruud PROUH50 T2 CD400-SO prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.

Where do homeowners screen Ruud PROUH50 T2 CD400-SO for recalls and tank age?

CPSC SaferProducts records show 2 brand-level recall notices mentioning Ruud as of 2026-11-23, including #07108 (2007-02-21). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

What alternative models sit closest to Ruud PROUH50 T2 CD400-SO in the Hybrid/Electric Heat Pump class?

Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH50 T2 FD400-30 (3.88 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)