Skip to main content
ENERGY STAR water heater model · PD 4692184

Ruud PROUH65 T2 RU400-Z30 Water Heater Specifications (4.05 UEF)

In the 706-unit Hybrid/Electric Heat Pump class, Ruud PROUH65 T2 RU400-Z30 (Electric) achieves a certified 4.05 UEF rating across its 59-gallon nominal tank, 75 gal First Hour Rating (rank #61 of 706, PD 4692184) and verifies as Pass: +1.55 / +62.0% for 2029 DOE floors. Rated annual electricity draw of 1,184 kWh/yr equates to roughly $215/yr ($2,150 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH65 T2 FD400-30 (4.05 UEF).

Uniform Energy Factor
4.05 UEF
Cohort UEF Rank
#61 of 706 (top 14.2%)
First Hour Rating
75 gal
Storage Volume
59 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.55 / +62.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Ruud PROUH65 T2 RU400-Z30 at 4.05 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50Ruud PROUH65 T2 RU400-Z30: 4.05
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Ruud PROUH65 T2 RU400-Z30 relative to the cohort median.
Efficiency comparison & rule summary

Ruud PROUH65 T2 RU400-Z30 records 4.05 UEF efficiency, putting it #61 of 706 among 706 Hybrid/Electric Heat Pump peers.

10 CFR 430.32(d)(2) compliance: Ruud PROUH65 T2 RU400-Z30 exceeds 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +1.55 UEF (+62.0%). At EIA August 2026 national rates (18.16 cents/kWh), 1,184 kWh/yr for Ruud PROUH65 T2 RU400-Z30 runs ~$215/yr vs. ~$946/yr for a 0.92 UEF electric tank.

State electric sensitivity for Ruud PROUH65 T2 RU400-Z30: 10-year operating spend spans $1,732 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,586 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Competing options beside Ruud PROUH65 T2 RU400-Z30 (4.05 UEF) are Friedrich PROH65 T2 FD400-30 (4.05 UEF, at parity) and Rheem CPROPH65 T2 RH375-SO (4.05 UEF, at parity).

How Do Ruud PROUH65 T2 RU400-Z30 Specs Compare to Hybrid/Electric Heat Pump Medians?

Ruud PROUH65 T2 RU400-Z30 places #61 of 706 (top 14.2%) across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRuud95 certified listingsENERGY STAR PD 4692184
Model NumberPROUH65 T2 RU400-Z30Draw pattern: High-UsagePROUH65 T2 RU400-Z30
Uniform Energy Factor (UEF)4.05+0.35 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)75 gal+3 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,184 kWh/yr+112 kWh/yr vs. 1,072 kWh/yr medianEst. $215/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency457%+28.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)64.2" H x 24.3" DVerify 72 in. vertical headroom; clears 28 in. utility doorway (24.3" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 21 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-1234YFLower-GWP refrigerant alignment (EPA AIM Act)EPA AIM Act Compliance
Certification Date2026-10-15Certified 2026-10-15Markets: United States

What Does PROUH65 T2 RU400-Z30 Cost to Operate Across State Electricity Rates?

At 1,184 kWh/yr, Ruud PROUH65 T2 RU400-Z30 runs roughly $215/yr on the EIA national average tier under August 2026 Table 5.6.A rates.

Estimated Annual Electricity Cost by State Rate (1,184 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$215.00/yrHawaii$559.00/yrCalifornia$352.00/yrTexas$188.00/yrWashington$173.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $215/yr $2,150 $7,315
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $559/yr $5,586 $19,004
California 29.75 ¢/kWh ($0.2975) $352/yr $3,522 $11,983
Texas 15.91 ¢/kWh ($0.1591) $188/yr $1,884 $6,409
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $173/yr $1,732 $5,893
Estimated electricity spend (1,184 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are There Active CPSC Safety Recalls for Ruud Water Heaters?

Our 2026-11-23 CPSC SaferProducts query surfaced 2 brand-level recall notices associated with Ruud; match your serial plate before repair. See Serial Number Lookup.

2 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #07108 (2007-02-21): Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard (CPSC Notice)
  • Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)

Which Certified Water Heaters Match PROUH65 T2 RU400-Z30 Most Closely?

These 5 competing Hybrid/Electric Heat Pump units sit nearest to Ruud PROUH65 T2 RU400-Z30 by storage capacity and 4.05 UEF rating.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Friedrich PROH65 T2 FD400-30 Hybrid/Electric Heat Pump 59 gal 75 gal 4.05 (at parity) 1,184
Rheem CPROPH65 T2 RH375-SO Hybrid/Electric Heat Pump 59 gal 75 gal 4.05 (at parity) 1,184
Richmond 10CE65-HP5S30 Hybrid/Electric Heat Pump 59 gal 75 gal 4.05 (at parity) 1,289
Bosch TR7000T-65CA Hybrid/Electric Heat Pump 60 gal 80 gal 3.9 (-0.15) 1,240
Friedrich PROH65 T2 FD400-SO Hybrid/Electric Heat Pump 59 gal 75 gal 4.05 (at parity) 1,184

What Installation Caveats Apply Before Buying Ruud PROUH65 T2 RU400-Z30?

Even high-UEF units like Ruud PROUH65 T2 RU400-Z30 (4.05 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

Key Limitations & Exclusions

  • Ruud PROUH65 T2 RU400-Z30 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Ruud PROUH65 T2 RU400-Z30 directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Ruud PROUH65 T2 RU400-Z30 Strong Fit — 4.05 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Friedrich PROH65 T2 FD400-30 footprint.

What Are the Key Questions About Ruud PROUH65 T2 RU400-Z30?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Is Ruud PROUH65 T2 RU400-Z30 eligible for continued manufacture past May 6, 2029?

At 4.05 UEF, Ruud PROUH65 T2 RU400-Z30 achieves Pass: +1.55 / +62.0% for the 2029 DOE standard and stands #61 of 706 (top 14.2%) against Friedrich PROH65 T2 FD400-30 and Rheem CPROPH65 T2 RH375-SO.

How tall and wide is Ruud PROUH65 T2 RU400-Z30, and what service clearance is needed?

Physical dimensions for Ruud PROUH65 T2 RU400-Z30 are 64.2 in. height and 24.3 in. diameter (verify 72 in. vertical headroom; clears 28 in. utility doorway (24.3" d)); verify stair turns and drain pan width before delivery.

Will Ruud PROUH65 T2 RU400-Z30 require upgrading household electrical panels or gas piping?

Ruud PROUH65 T2 RU400-Z30 draws 240V at 21A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.

Is Ruud PROUH65 T2 RU400-Z30 economical to operate at 18.16 cents/kWh US electric rates?

Expect roughly $215/yr ($2,150 over 10 years) to power Ruud PROUH65 T2 RU400-Z30 at 1,184 kWh/yr under the 18.16 cents/kWh US average (ranging from $173/yr in Washington hydro tiers up to $559/yr in Hawaii).

Which installation bottlenecks limit Ruud PROUH65 T2 RU400-Z30?

If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, Ruud PROUH65 T2 RU400-Z30 drops into resistance mode more often.

How does Ruud PROUH65 T2 RU400-Z30 handle simultaneous showers and laundry?

Delivering 75 gal in the first hour (+3 gal vs. 72 gal median), Ruud PROUH65 T2 RU400-Z30 combines 59 gal tank storage with rapid burner/element recovery.

How long is the warranty on Ruud PROUH65 T2 RU400-Z30 and how do you decode its serial?

CPSC SaferProducts records show 2 brand-level recall notices mentioning Ruud as of 2026-11-23, including #07108 (2007-02-21). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

How do 2026 post-OBBBA rebates affect buying Ruud PROUH65 T2 RU400-Z30?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH65 T2 FD400-30 (4.05 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks