SAMMLER A168 Water Heater Specifications (99 SUEF)
Certified at 99.0 SUEF across its 42-gallon nominal tank, SAMMLER A168 (Solar with Gas Backup, Natural Gas) places #1 of 25 out of 25 ENERGY STAR models (PD 2408366). Its May 6, 2029 10 CFR 430.32 status reads Exempt — Solar SUEF. Annual fuel cost depends on regional gas/fuel tariffs and wall-hung / compact envelope. Closest certified alternative is SunEarth C2-26T-40-TLG (3.3 SUEF).
- Solar UEF (SUEF)
- 99.0 SUEF
- Cohort SUEF Rank
- #1 of 25
- First Hour Rating
- On-Demand
- Storage Volume
- 42 gal
- Fuel / Type
- Natural Gas / Solar with Gas Backup
- DOE 2029 Rule Status
- Exempt — Solar SUEF

Tested at 99.0 SUEF, SAMMLER A168 places #1 of 25 across 25 certified Solar with Gas Backup configurations (+14.50 SUEF vs. 84.50 SUEF median).
Solar collector & storage profile, OG-300 #30004301 for SAMMLER A168: Direct Thermosyphon architecture; 22.7 sq ft Flat Plate collector; 42 gal storage tank; freeze limit 39 deg F.
Closest alternatives to SAMMLER A168 include SunEarth C2-26T-40-TLG (3.3 SUEF, delta -95.70) alongside Solahart ASTG 181J (99.0 SUEF, at parity).
Which Specs Set SAMMLER A168 Apart From Cohort Averages?
Ranked #1 of 25 inside the 25-model Solar with Gas Backup cohort, SAMMLER A168 is evaluated row by row below against category medians.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | SAMMLER | 8 certified listings | ENERGY STAR PD 2408366 |
| Model Number | A168 | Draw pattern: Very-Small-Usage | A168 |
| Solar Uniform Energy Factor (SUEF) | 99.0 | +14.50 SUEF vs. 84.50 SUEF median | 10 CFR 430 Test Method |
| Solar System & Collector | Direct Thermosyphon (Flat Plate) | 22.7 sq ft aperture | OG-300 #30004301 |
| Collector Freeze Tolerance | 39 °F | SRCC freeze protection rating | ENERGY STAR Solar Dataset |
| Certification Date | 2020-01-22 | Certified 2020-01-22 | Markets: United States |
What Should SAMMLER Owners Check in CPSC Recall Logs?
The 2026-11-23 CPSC recall sweep recorded zero brand matches for SAMMLER; run a quick serial-number check to verify age before replacing wear parts. See Serial Number Lookup.
How Do Five Nearby Solar with Gas Backup Models Stack Up?
Five alternative Solar with Gas Backup units with nearly identical gallon storage and SUEF scores are listed below alongside exact efficiency spreads.
| Brand & Model | Type | Vol | FHR | SUEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| SunEarth C2-26T-40-TLG | Solar with Gas Backup | 40 gal | — | 3.3 (-95.70) | — |
| Solahart ASTG 181J | Solar with Gas Backup | 48 gal | — | 99.0 (at parity) | — |
| GREENoneTEC Double GT | Solar with Gas Backup | 51 gal | — | 6.7 (-92.30) | — |
| Heliodyne HPAK 1 406 GT 65 ACD Z | Solar with Gas Backup | 65 gal | — | 99.0 (at parity) | — |
| Solahart ASTG 181J Free Heat | Solar with Gas Backup | 48 gal | — | 99.0 (at parity) | — |
What Installation Caveats Apply Before Buying SAMMLER A168?
Even high-UEF units like SAMMLER A168 (99.0 SUEF) carry physical space, condensate, and fuel-line prerequisites noted below.
Key Limitations & Exclusions
- SAMMLER A168 logs 99.0 SUEF (Exempt — Solar SUEF); check May 6, 2029 10 CFR 430.32 transition status.
- Drain tank sediment yearly and inspect SAMMLER A168's sacrificial anode rod every 4–6 years.
- Peak simultaneous draws exceeding 42 gal will deplete stored recovery capacity.
Which Option Fits Your Situation?
Frequently Asked Technical Questions: SAMMLER A168
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Is SAMMLER A168 eligible for continued manufacture past May 6, 2029?
SAMMLER A168 holds 99.0 SUEF certification in the 25-unit Solar with Gas Backup tier, remaining unaffected by the May 6, 2029 electric storage UEF mandate.
How tall and wide is SAMMLER A168, and what service clearance is needed?
SAMMLER A168 saves floor space via its solar with gas backup layout (wall-hung / compact envelope); inspect service-valve swing clearance below the bottom manifold.
Will SAMMLER A168 require upgrading household electrical panels or gas piping?
Check Natural Gas piping and venting for SAMMLER A168 (120V AC ignition/fan + gas piping check); undersized 1/2 in. gas branches cause peak-demand ignition lockouts on high-input burners.
Is SAMMLER A168 economical to operate at 18.16 cents/kWh US electric rates?
Fuel bills for SAMMLER A168 (Natural Gas, 99.0 SUEF) hinge on household gallon demand and local gas utility tariffs compared with SunEarth C2-26T-40-TLG.
Which installation bottlenecks limit SAMMLER A168?
Check local 10 CFR 430.32(d)(2) phase-in timing (Exempt — Solar SUEF) and physical doorway clearances before choosing SAMMLER A168 over SunEarth C2-26T-40-TLG.
How does SAMMLER A168 handle simultaneous showers and laundry?
SAMMLER A168 supplies endless hot water within its maximum BTU/flow curve—check cold-climate winter groundwater temperatures before running 3+ fixtures at once.
How long is the warranty on SAMMLER A168 and how do you decode its serial?
CPSC records show 0 active plumbing recalls for SAMMLER as of 2026-11-23. Confirm install proof and serial manufacture year on SAMMLER A168 before calling service.
How do 2026 post-OBBBA rebates affect buying SAMMLER A168?
Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Solar with Gas Backup is SunEarth C2-26T-40-TLG (3.3 SUEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)