Skip to main content
ENERGY STAR water heater model · PD 2409616

SunEarth C2-26T-40-TLG Water Heater Specifications (3.3 SUEF)

Certified at 3.3 SUEF across its 40-gallon nominal tank, SunEarth C2-26T-40-TLG (Solar with Gas Backup, Natural Gas) places #24 of 25 out of 25 ENERGY STAR models (PD 2409616). Its May 6, 2029 10 CFR 430.32 status reads Exempt — Solar SUEF. Annual fuel cost depends on regional gas/fuel tariffs and wall-hung / compact envelope. Closest certified alternative is SAMMLER A168 (99.0 SUEF).

Solar UEF (SUEF)
3.3 SUEF
Cohort SUEF Rank
#24 of 25
First Hour Rating
On-Demand
Storage Volume
40 gal
Fuel / Type
Natural Gas / Solar with Gas Backup
DOE 2029 Rule Status
Exempt — Solar SUEF
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Solar with Gas Backup SUEF Efficiency Distribution (25 Certified Units)Distribution of certified SUEF ratings across 25 units in Solar with Gas Backup, marking SunEarth C2-26T-40-TLG at 3.3 SUEF.9112121.90 SUEF99.00 SUEFMedian 84.50SunEarth C2-26T-40-TLG: 3.30
Solar with Gas Backup SUEF Efficiency Distribution (25 Certified Units). Highlighted pin shows SunEarth C2-26T-40-TLG relative to the cohort median.
Efficiency comparison & rule summary

Tested at 3.3 SUEF, SunEarth C2-26T-40-TLG places #24 of 25 across 25 certified Solar with Gas Backup configurations (-81.20 SUEF vs. 84.50 SUEF median).

Solar collector & storage profile, OG-300 #30004363 for SunEarth C2-26T-40-TLG: Indirect Forced Circulation architecture; 26.9 sq ft Flat Plate collector; 40 gal storage tank; freeze limit -30 deg F.

Closest alternatives to SunEarth C2-26T-40-TLG include SAMMLER A168 (99.0 SUEF, delta +95.70) alongside Solahart ASTG 181J (99.0 SUEF, delta +95.70).

How Do SunEarth C2-26T-40-TLG Specs Compare to Solar with Gas Backup Medians?

SunEarth C2-26T-40-TLG places #24 of 25 across 25 certified Solar with Gas Backup configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 25 ENERGY STAR Solar with Gas Backup peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandSunEarth3 certified listingsENERGY STAR PD 2409616
Model NumberC2-26T-40-TLGDraw pattern: Low-UsageC2-26T-40-TLG
Solar Uniform Energy Factor (SUEF)3.3-81.20 SUEF vs. 84.50 SUEF median10 CFR 430 Test Method
Solar System & CollectorIndirect Forced Circulation (Flat Plate)26.9 sq ft apertureOG-300 #30004363
Collector Freeze Tolerance-30 °FSRCC freeze protection ratingENERGY STAR Solar Dataset
Certification Date2022-01-12Certified 2022-01-12Markets: United States
Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are There Active CPSC Safety Recalls for SunEarth Water Heaters?

Zero active CPSC recalls matched SunEarth in our 2026-11-23 SaferProducts sweep; verify your individual tank date code via our lookup tool. See Serial Number Lookup.

Which Certified Water Heaters Match C2-26T-40-TLG Most Closely?

These 5 competing Solar with Gas Backup units sit nearest to SunEarth C2-26T-40-TLG by storage capacity and 3.3 SUEF rating.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRSUEF (Δ)kWh/yr
SAMMLER A168 Solar with Gas Backup 42 gal — 99.0 (+95.70) —
Solahart ASTG 181J Solar with Gas Backup 48 gal — 99.0 (+95.70) —
GREENoneTEC Double GT Solar with Gas Backup 51 gal — 6.7 (+3.40) —
Heliodyne HPAK 1 406 GT 65 ACD Z Solar with Gas Backup 65 gal — 99.0 (+95.70) —
SAMMLER A169 Solar with Gas Backup 42 gal — 17.2 (+13.90) —

Which Home Setups Are NOT a Fit for SunEarth C2-26T-40-TLG?

Comparing SunEarth C2-26T-40-TLG against SAMMLER A168 requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

Key Limitations & Exclusions

  • SunEarth C2-26T-40-TLG logs 3.3 SUEF (Exempt — Solar SUEF); check May 6, 2029 10 CFR 430.32 transition status.
  • Drain tank sediment yearly and inspect SunEarth C2-26T-40-TLG's sacrificial anode rod every 4–6 years.
  • Peak simultaneous draws exceeding 40 gal will deplete stored recovery capacity.

Which Option Fits Your Situation?

Direct Footprint Replacement for SunEarth C2-26T-40-TLG Strong Fit — Matches existing plumbing and vent clearances.
2026 Post-OBBBA Rebate Buyers Verify Tier — DOE HEAR ($1,750 max) targets >=2.30 UEF heat pump models like SAMMLER A168.
Very Hard Well Water (>10.5 GPG) Add Softener / Flush — Schedule 6-month tank sediment drains.

What Are the Key Questions About SunEarth C2-26T-40-TLG?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does SunEarth C2-26T-40-TLG score under 10 CFR 430.32 May 2029 water heater minimums?

Under 10 CFR 430.32, solar models like SunEarth C2-26T-40-TLG (3.3 SUEF) are evaluated by Solar Uniform Energy Factor rather than standard electric or gas tank thresholds.

What physical clearance dimensions apply when installing SunEarth C2-26T-40-TLG?

Because SunEarth C2-26T-40-TLG is a solar with gas backup unit (wall-hung / compact envelope), check wall-stud backing, condensate neutralizer routing, and outdoor vent clearances first.

What 240V circuit or IFGC fuel line capacity fits SunEarth C2-26T-40-TLG?

SunEarth C2-26T-40-TLG utilizes Natural Gas combustion (120V AC ignition/fan + gas piping check). Confirm static/dynamic manifold pressure and 120V GFCI outlet availability before swapping out an older storage tank.

How do state electricity prices change annual costs for SunEarth C2-26T-40-TLG?

SunEarth C2-26T-40-TLG operates on Natural Gas (3.3 SUEF); check regional therm costs and hot-water recirculation schedules since tankless standby electricity stays minimal.

What homeowner setups should avoid choosing SunEarth C2-26T-40-TLG?

Homes with >10.5 GPG Very Hard well water without regular 6-month sediment draining will shorten the tank life of SunEarth C2-26T-40-TLG (Exempt — Solar SUEF).

Is SunEarth C2-26T-40-TLG sized adequately for a 2-to-4-person household?

Instead of First Hour Rating, SunEarth C2-26T-40-TLG heats water continuously; two concurrent 2.0 GPM showers and a faucet require ~5.5 GPM at a 70 °F temperature rise.

Does SunEarth have active CPSC SaferProducts notices affecting C2-26T-40-TLG?

Zero CPSC recall alerts matched SunEarth (2026-11-23 check). Keep your SunEarth C2-26T-40-TLG serial code handy to track standard 6-to-12-year OEM warranty coverage.

Which competing water heater matches SunEarth C2-26T-40-TLG (3.3 SUEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for SunEarth C2-26T-40-TLG. Closest peer in Solar with Gas Backup is SAMMLER A168 (99.0 SUEF).