Skip to main content
ENERGY STAR water heater model · PD 2408375

SAMMLER A169 Water Heater Specifications (17.2 SUEF)

The SAMMLER A169 (Solar with Gas Backup, Natural Gas) achieves a certified 17.2 SUEF rating across its 42-gallon nominal tank, ranking #16 of 25 among 25 ENERGY STAR Solar with Gas Backup models (PD 2408375). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Exempt — Solar SUEF. Annual fuel cost depends on regional gas/fuel tariffs and wall-hung / compact envelope. Closest certified alternative is SunEarth C2-26T-40-TLG (3.3 SUEF).

Solar UEF (SUEF)
17.2 SUEF
Cohort SUEF Rank
#16 of 25
First Hour Rating
On-Demand
Storage Volume
42 gal
Fuel / Type
Natural Gas / Solar with Gas Backup
DOE 2029 Rule Status
Exempt — Solar SUEF
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Solar with Gas Backup SUEF Efficiency Distribution (25 Certified Units)Distribution of certified SUEF ratings across 25 units in Solar with Gas Backup, marking SAMMLER A169 at 17.2 SUEF.9112121.90 SUEF99.00 SUEFMedian 84.50SAMMLER A169: 17.20
Solar with Gas Backup SUEF Efficiency Distribution (25 Certified Units). Highlighted pin shows SAMMLER A169 relative to the cohort median.
Efficiency comparison & rule summary

SAMMLER A169 (17.2 SUEF) ranks #16 of 25 Solar with Gas Backup models — more efficient than 36% of Solar with Gas Backup models, -67.30 SUEF below the 84.50 SUEF median.

Solar collector & storage profile, OG-300 #30004305 for SAMMLER A169: Direct Thermosyphon architecture; 27.1 sq ft Flat Plate collector; 42 gal storage tank; freeze limit 39 deg F.

Peer comparison: SAMMLER A169 (17.2 SUEF) compares closely with SunEarth C2-26T-40-TLG (3.3 SUEF, delta -13.90) and Solahart ASTG 181J (99.0 SUEF, delta +81.80).

How Complete Are the Certified Metrics for SAMMLER A169?

Standing at #16 of 25 among 25 certified Solar with Gas Backup heaters, SAMMLER A169 brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 25 ENERGY STAR Solar with Gas Backup peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandSAMMLER8 certified listingsENERGY STAR PD 2408375
Model NumberA169Draw pattern: Low-UsageA169
Solar Uniform Energy Factor (SUEF)17.2-67.30 SUEF vs. 84.50 SUEF median10 CFR 430 Test Method
Solar System & CollectorDirect Thermosyphon (Flat Plate)27.1 sq ft apertureOG-300 #30004305
Collector Freeze Tolerance39 °FSRCC freeze protection ratingENERGY STAR Solar Dataset
Certification Date2020-01-22Certified 2020-01-22Markets: United States
Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are SAMMLER Models Affected by Current CPSC Notices?

Zero brand-level CPSC hazard notices matched SAMMLER in our 2026-11-23 feed; decode your water heater's serial number below to confirm warranty status. See Serial Number Lookup.

Which 5 Models Offer Similar Output to A169?

Ordered by minimal capacity and SUEF spread relative to SAMMLER A169, these five certified peers give direct replacement benchmarks.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRSUEF (Δ)kWh/yr
SunEarth C2-26T-40-TLG Solar with Gas Backup 40 gal — 3.3 (-13.90) —
Solahart ASTG 181J Solar with Gas Backup 48 gal — 99.0 (+81.80) —
GREENoneTEC Double GT Solar with Gas Backup 51 gal — 6.7 (-10.50) —
Heliodyne HPAK 1 406 GT 65 ACD Z Solar with Gas Backup 65 gal — 99.0 (+81.80) —
Solahart ASTG 181J Free Heat Solar with Gas Backup 48 gal — 99.0 (+81.80) —

Who Is SAMMLER A169 Best For — and When Should You Pick SunEarth C2-26T-40-TLG?

Evaluate whether SAMMLER A169's Solar with Gas Backup architecture matches your existing mechanical room and local utility tariffs before purchasing.

Key Limitations & Exclusions

  • SAMMLER A169 logs 17.2 SUEF (Exempt — Solar SUEF); check May 6, 2029 10 CFR 430.32 transition status.
  • Drain tank sediment yearly and inspect SAMMLER A169's sacrificial anode rod every 4–6 years.
  • Peak simultaneous draws exceeding 42 gal will deplete stored recovery capacity.

Which Option Fits Your Situation?

Direct Footprint Replacement for SAMMLER A169 Strong Fit — Matches existing plumbing and vent clearances.
2026 Post-OBBBA Rebate Buyers Verify Tier — DOE HEAR ($1,750 max) targets >=2.30 UEF heat pump models like SunEarth C2-26T-40-TLG.
Very Hard Well Water (>10.5 GPG) Add Softener / Flush — Schedule 6-month tank sediment drains.

Practical Specs & Code Questions for SAMMLER A169

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does SAMMLER A169 (17.2 SUEF) compare to 2029 federal DOE floors?

Because SAMMLER A169 harvests solar thermal energy (17.2 SUEF), federal 10 CFR 430.32 tank minimums do not restrict its sale in 2029 or beyond.

Does SAMMLER A169 fit inside a tight hallway closet or low-headroom utility room?

Designed as a compact solar with gas backup platform (wall-hung / compact envelope), SAMMLER A169 still needs code-compliant flue separation from windows and gas meters.

What power supply or fuel line specs govern SAMMLER A169?

Installing SAMMLER A169 on Natural Gas involves 120V AC ignition/fan + gas piping check. Verify regulator capacity and dedicated Category IV PVC venting rather than reusing legacy galvanized flues.

What annual utility bill should homeowners budget for SAMMLER A169?

Rated 17.2 SUEF on Natural Gas, SAMMLER A169 carries no whole-house kWh heating draw; confirm annual therm usage against 25 Solar with Gas Backup models.

What are the main drawbacks of SAMMLER A169 (17.2 SUEF)?

Buyers expecting endless simultaneous shower flow beyond 42 gal should compare condensing tankless units or larger-capacity tanks.

What hot-water delivery rating governs SAMMLER A169?

On-demand Solar with Gas Backup sizing for SAMMLER A169 depends on winter inlet water temp (typically 45–65 °F) heated to a 120 °F anti-scald setpoint.

Where do homeowners screen SAMMLER A169 for recalls and tank age?

Verified clean against 2026-11-23 CPSC recall feeds for SAMMLER; use our browser-only serial decoder to inspect SAMMLER A169's age and warranty window.

What alternative models sit closest to SAMMLER A169 in the Solar with Gas Backup class?

Closest peer in Solar with Gas Backup is SunEarth C2-26T-40-TLG (3.3 SUEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks