Skip to main content
ENERGY STAR water heater model · PD 3701842

SANCO2 GS5-45HPC-D HP + ECO-43SSAQB Water Heater Specifications (3.7 UEF)

Engineered as a Electric Hybrid/Electric Heat Pump unit, SANCO2 GS5-45HPC-D HP + ECO-43SSAQB achieves a certified 3.7 UEF rating across its 43-gallon nominal tank, 73 gal First Hour Rating and ranks #347 of 706 in its 706-model cohort (PD 3701842), recording Pass: +1.40 / +60.9% under 2029 DOE rules. Rated annual electricity draw of 868 kWh/yr equates to roughly $158/yr ($1,576 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Navien NWP500S050AUMB (3.85 UEF).

Uniform Energy Factor
3.7 UEF
Cohort UEF Rank
#347 of 706
First Hour Rating
73 gal
Storage Volume
43 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.40 / +60.9%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking SANCO2 GS5-45HPC-D HP + ECO-43SSAQB at 3.7 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30SANCO2 GS5-45HPC-D HP + ECO-43SSAQB: 3.70
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows SANCO2 GS5-45HPC-D HP + ECO-43SSAQB relative to the cohort median.
Efficiency comparison & rule summary

Within the 706-unit Hybrid/Electric Heat Pump cohort, SANCO2 GS5-45HPC-D HP + ECO-43SSAQB logs 3.7 UEF and ranks #347 of 706.

Against 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF), SANCO2 GS5-45HPC-D HP + ECO-43SSAQB holds a +1.40 UEF (+60.9%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 868 kWh/yr for SANCO2 GS5-45HPC-D HP + ECO-43SSAQB runs ~$158/yr vs. ~$634/yr for a 0.92 UEF electric tank. Acoustic output is 37 dBA (quieter than 93.3% of Hybrid/Electric Heat Pump models).

State electric sensitivity for SANCO2 GS5-45HPC-D HP + ECO-43SSAQB: 10-year operating spend spans $1,270 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,095 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Cross-shopping SANCO2 GS5-45HPC-D HP + ECO-43SSAQB (3.7 UEF)? Check Navien NWP500S050AUMB (3.85 UEF, delta +0.15) and Arctic Arctic-HP-Hot Water-KA06-50 (3.88 UEF, delta +0.18).

What Physical and Thermal Ratings Define SANCO2 GS5-45HPC-D HP + ECO-43SSAQB?

Positioning at #347 of 706 out of 706 Hybrid/Electric Heat Pump peers, SANCO2 GS5-45HPC-D HP + ECO-43SSAQB pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandSANCO26 certified listingsENERGY STAR PD 3701842
Model NumberGS5-45HPC-D HP + ECO-43SSAQBDraw pattern: Medium-UsageGS5-45HPC-D HP + ECO-43SSAQB
Uniform Energy Factor (UEF)3.7At 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)73 gal+1 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use868 kWh/yr-204 kWh/yr vs. 1,072 kWh/yr medianEst. $158/yr @ $0.1816/kWh (EIA US Avg)
Electrical Circuit Requirements230 V / 7 A maxVerify rating plate electrical drawNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-744 (CO₂) (GWP:1 | Lower GWP)Lower-GWP refrigerant alignment (EPA AIM Act)EPA AIM Act Compliance
Sound Pressure Level37 dBAtop 6.7% · quieter than 93.3% of Hybrid/Electric Heat Pump models · -12 dBA vs. 49 dBA medianIndoor placement check
Certification Date2024-10-09Certified 2024-10-09Markets: United States, Canada

Why Do State Utility Rates Shift GS5-45HPC-D HP + ECO-43SSAQB Running Costs?

Consuming 868 kWh annually puts SANCO2 GS5-45HPC-D HP + ECO-43SSAQB near $158/yr at US baseline tariffs, with multi-state EIA comparisons charted below.

Estimated Annual Electricity Cost by State Rate (868 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$158.00/yrHawaii$410.00/yrCalifornia$258.00/yrTexas$138.00/yrWashington$127.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $158/yr $1,576 $4,763
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $410/yr $4,095 $12,375
California 29.75 ¢/kWh ($0.2975) $258/yr $2,582 $7,803
Texas 15.91 ¢/kWh ($0.1591) $138/yr $1,381 $4,173
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $127/yr $1,270 $3,837
Estimated electricity spend (868 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Have Any SANCO2 Series Triggered CPSC Recalls?

SaferProducts screening on 2026-11-23 returned zero recall matches for SANCO2; confirm tank age separately using the rating-plate serial pattern. See Serial Number Lookup.

What Are 5 Direct Alternatives to SANCO2 GS5-45HPC-D HP + ECO-43SSAQB?

Homeowners cross-shopping SANCO2 GS5-45HPC-D HP + ECO-43SSAQB frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Navien NWP500S050AUMB Hybrid/Electric Heat Pump 44 gal 65 gal 3.85 (+0.15) 840
Arctic Arctic-HP-Hot Water-KA06-50 Hybrid/Electric Heat Pump 44.5 gal 65 gal 3.88 (+0.18) 837
PHNIX KA06-50 Hybrid/Electric Heat Pump 44.5 gal 65 gal 3.88 (+0.18) 837
AMERICAN STANDARD WATER HEATERS ASHPWH-50***** Hybrid/Electric Heat Pump 45 gal 68 gal 3.75 (+0.05) 867
Ariston ARIHPWH-50 Hybrid/Electric Heat Pump 45 gal 68 gal 3.75 (+0.05) 867

Which Home Setups Are NOT a Fit for SANCO2 GS5-45HPC-D HP + ECO-43SSAQB?

Comparing SANCO2 GS5-45HPC-D HP + ECO-43SSAQB against Navien NWP500S050AUMB requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

Key Limitations & Exclusions

  • SANCO2 GS5-45HPC-D HP + ECO-43SSAQB needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 37 dBA; avoid mounting SANCO2 GS5-45HPC-D HP + ECO-43SSAQB directly beside quiet bedrooms.
  • Requires condensate drain routing and 230V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing SANCO2 GS5-45HPC-D HP + ECO-43SSAQB Strong Fit — 3.7 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Navien NWP500S050AUMB footprint.

Sizing, Efficiency & Recall Answers for SANCO2 GS5-45HPC-D HP + ECO-43SSAQB

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does SANCO2 GS5-45HPC-D HP + ECO-43SSAQB score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; SANCO2 GS5-45HPC-D HP + ECO-43SSAQB logs 3.7 UEF (Pass: +1.40 / +60.9%) within the 706-unit Hybrid/Electric Heat Pump group.

What physical clearance dimensions apply when installing SANCO2 GS5-45HPC-D HP + ECO-43SSAQB?

Because SANCO2 GS5-45HPC-D HP + ECO-43SSAQB is a hybrid/electric heat pump unit (wall-hung / compact envelope), check wall-stud backing, condensate neutralizer routing, and outdoor vent clearances first.

What 240V circuit or IFGC fuel line capacity fits SANCO2 GS5-45HPC-D HP + ECO-43SSAQB?

Powered via 230V at 7A max, SANCO2 GS5-45HPC-D HP + ECO-43SSAQB requires: Verify rating plate electrical draw. Confirm double-pole breaker sizing and condensate pump outlet proximity.

How do state electricity prices change annual costs for SANCO2 GS5-45HPC-D HP + ECO-43SSAQB?

Annual electric spend for SANCO2 GS5-45HPC-D HP + ECO-43SSAQB (868 kWh/yr) averages $158/yr nationwide (ranging from $127/yr in Washington hydro tiers up to $410/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.

What homeowner setups should avoid choosing SANCO2 GS5-45HPC-D HP + ECO-43SSAQB?

Homes lacking a condensate drain or 230V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on SANCO2 GS5-45HPC-D HP + ECO-43SSAQB.

Is SANCO2 GS5-45HPC-D HP + ECO-43SSAQB sized adequately for a 2-to-4-person household?

ENERGY STAR certifies SANCO2 GS5-45HPC-D HP + ECO-43SSAQB at 73 gal First Hour Rating (+1 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.

Does SANCO2 have active CPSC SaferProducts notices affecting GS5-45HPC-D HP + ECO-43SSAQB?

Zero CPSC recall alerts matched SANCO2 (2026-11-23 check). Keep your SANCO2 GS5-45HPC-D HP + ECO-43SSAQB serial code handy to track standard 6-to-12-year OEM warranty coverage.

Which competing water heater matches SANCO2 GS5-45HPC-D HP + ECO-43SSAQB (3.7 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for SANCO2 GS5-45HPC-D HP + ECO-43SSAQB. Closest peer in Hybrid/Electric Heat Pump is Navien NWP500S050AUMB (3.85 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks