SANCO2 GS5-45HPC-D HP + ECO-83SSAQB Water Heater Specifications (3.8 UEF)
With PD 3624318 certification, SANCO2 GS5-45HPC-D HP + ECO-83SSAQB (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.8 UEF rating across its 83-gallon nominal tank, 121 gal First Hour Rating, standing #268 of 706 across 706 peers with Pass: +1.30 / +52.0% for May 6, 2029. Rated annual electricity draw of 1,313 kWh/yr equates to roughly $238/yr ($2,384 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPS10-80H45DV 2** (3.88 UEF).
- Uniform Energy Factor
- 3.8 UEF
- Cohort UEF Rank
- #268 of 706 (top 41.9%)
- First Hour Rating
- 121 gal
- Storage Volume
- 83 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.30 / +52.0%

ENERGY STAR certification places SANCO2 GS5-45HPC-D HP + ECO-83SSAQB at 3.8 UEF (#268 of 706; +0.10 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.
May 6, 2029 readiness: SANCO2 GS5-45HPC-D HP + ECO-83SSAQB stands +1.30 UEF (+52.0%) relative to 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,313 kWh/yr for SANCO2 GS5-45HPC-D HP + ECO-83SSAQB runs ~$238/yr vs. ~$985/yr for a 0.92 UEF electric tank. Acoustic output is 37 dBA (quieter than 93.3% of Hybrid/Electric Heat Pump models).
State electric sensitivity for SANCO2 GS5-45HPC-D HP + ECO-83SSAQB: 10-year operating spend spans $1,921 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,195 in Hawaii (Highest EIA State) (47.18 cents/kWh).
In the Hybrid/Electric Heat Pump tier, A. O. Smith HPS10-80H45DV 2** (3.88 UEF, delta +0.08) and American HPS10280H045DV 2** (3.88 UEF, delta +0.08) bracket SANCO2 GS5-45HPC-D HP + ECO-83SSAQB.
Which Specs Set SANCO2 GS5-45HPC-D HP + ECO-83SSAQB Apart From Cohort Averages?
Ranked #268 of 706 (top 41.9%) inside the 706-model Hybrid/Electric Heat Pump cohort, SANCO2 GS5-45HPC-D HP + ECO-83SSAQB is evaluated row by row below against category medians.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | SANCO2 | 6 certified listings | ENERGY STAR PD 3624318 |
| Model Number | GS5-45HPC-D HP + ECO-83SSAQB | Draw pattern: High-Usage | GS5-45HPC-D HP + ECO-83SSAQB |
| Uniform Energy Factor (UEF) | 3.8 | +0.10 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 121 gal | +49 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,313 kWh/yr | +241 kWh/yr vs. 1,072 kWh/yr median | Est. $238/yr @ $0.1816/kWh (EIA US Avg) |
| Electrical Circuit Requirements | 230 V / 7 A max | Verify rating plate electrical draw | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-744 (CO₂) (GWP:1 | Lower GWP) | Lower-GWP refrigerant alignment (EPA AIM Act) | EPA AIM Act Compliance |
| Sound Pressure Level | 37 dBA | top 6.7% · quieter than 93.3% of Hybrid/Electric Heat Pump models · -12 dBA vs. 49 dBA median | Indoor placement check |
| Certification Date | 2024-08-21 | Certified 2024-08-21 | Markets: United States, Canada |
How Do Regional kWh Prices Impact GS5-45HPC-D HP + ECO-83SSAQB Over 10 Years?
Using EIA Table 5.6.A benchmarks, SANCO2 GS5-45HPC-D HP + ECO-83SSAQB's 1,313 kWh/yr draw translates to roughly $238/yr on typical US residential bills.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $238/yr | $2,384 | $7,464 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $619/yr | $6,195 | $19,391 |
| California | 29.75 ¢/kWh ($0.2975) | $391/yr | $3,906 | $12,227 |
| Texas | 15.91 ¢/kWh ($0.1591) | $209/yr | $2,089 | $6,539 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $192/yr | $1,921 | $6,013 |
What Should SANCO2 Owners Check in CPSC Recall Logs?
The 2026-11-23 CPSC recall sweep recorded zero brand matches for SANCO2; run a quick serial-number check to verify age before replacing wear parts. See Serial Number Lookup.
How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?
Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| A. O. Smith HPS10-80H45DV 2** | Hybrid/Electric Heat Pump | 82 gal | 95 gal | 3.88 (+0.08) | 1,279 |
| American HPS10280H045DV 2** | Hybrid/Electric Heat Pump | 82 gal | 95 gal | 3.88 (+0.08) | 1,279 |
| Lochinvar HPSA080KD 2** | Hybrid/Electric Heat Pump | 82 gal | 95 gal | 3.88 (+0.08) | 1,279 |
| RELIANCE WATER HEATERS 10-80-DHPTS 2** | Hybrid/Electric Heat Pump | 82 gal | 95 gal | 3.88 (+0.08) | 1,279 |
| A. O. Smith HPSN10-80H45DV 2** | Hybrid/Electric Heat Pump | 82 gal | 95 gal | 3.88 (+0.08) | 1,279 |
When Should Homeowners Skip SANCO2 GS5-45HPC-D HP + ECO-83SSAQB (Hybrid/Electric Heat Pump)?
Check SANCO2 GS5-45HPC-D HP + ECO-83SSAQB's mechanical constraints—including utility space, Electric capacity, and Pass: +1.30 / +52.0% status—against typical residential installations.
Key Limitations & Exclusions
- SANCO2 GS5-45HPC-D HP + ECO-83SSAQB needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 37 dBA; avoid mounting SANCO2 GS5-45HPC-D HP + ECO-83SSAQB directly beside quiet bedrooms.
- Requires condensate drain routing and 230V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Frequently Asked Technical Questions: SANCO2 GS5-45HPC-D HP + ECO-83SSAQB
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Will SANCO2 GS5-45HPC-D HP + ECO-83SSAQB stay compliant after the May 6, 2029 DOE standard takes effect?
Tested at 3.8 UEF, SANCO2 GS5-45HPC-D HP + ECO-83SSAQB shows Pass: +1.30 / +52.0% relative to May 6, 2029 federal DOE limits while placing #268 of 706 (top 41.9%) among 706 Hybrid/Electric Heat Pump peers like A. O. Smith HPS10-80H45DV 2**.
Will SANCO2 GS5-45HPC-D HP + ECO-83SSAQB fit through a standard utility door and 72-inch basement ceiling?
Using a wall-mounted hybrid/electric heat pump chassis, SANCO2 GS5-45HPC-D HP + ECO-83SSAQB eliminates floor-tank footprint (wall-hung / compact envelope), though Category IV exhaust and drain clearance remain mandatory.
Do existing utility hookups support SANCO2 GS5-45HPC-D HP + ECO-83SSAQB during replacement?
Electrical specs for SANCO2 GS5-45HPC-D HP + ECO-83SSAQB call for 230V at 7A max (Verify rating plate electrical draw). Have a licensed electrician inspect panel load and wire gauge.
What is the estimated 10-year operating spend for SANCO2 GS5-45HPC-D HP + ECO-83SSAQB?
At 18.16 cents/kWh national residential pricing, SANCO2 GS5-45HPC-D HP + ECO-83SSAQB's 1,313 kWh/yr draw equals roughly $238 annually or $2,380 across a 10-year horizon (ranging from $192/yr in Washington hydro tiers up to $619/yr in Hawaii).
When is SANCO2 GS5-45HPC-D HP + ECO-83SSAQB a poor fit for a residential replacement?
Avoid placing SANCO2 GS5-45HPC-D HP + ECO-83SSAQB directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 37 dBA sound and cool exhaust airflow.
What First Hour Rating or flow capacity does SANCO2 GS5-45HPC-D HP + ECO-83SSAQB deliver?
With 121 gal FHR (+49 gal vs. 72 gal median), SANCO2 GS5-45HPC-D HP + ECO-83SSAQB fits larger 3–5 person homes cleanly.
How do you verify manufacturing age and recall status on SANCO2 GS5-45HPC-D HP + ECO-83SSAQB?
Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for SANCO2; verify exact manufacturing week for SANCO2 GS5-45HPC-D HP + ECO-83SSAQB using the Serial Number Lookup tool.
Does SANCO2 GS5-45HPC-D HP + ECO-83SSAQB qualify for DOE HEAR incentives after 25C expired?
After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for SANCO2 GS5-45HPC-D HP + ECO-83SSAQB. Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPS10-80H45DV 2** (3.88 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)