Skip to main content
ENERGY STAR water heater model · PD 3624318

SANCO2 GS5-45HPC-D HP + ECO-83SSAQB Water Heater Specifications (3.8 UEF)

With PD 3624318 certification, SANCO2 GS5-45HPC-D HP + ECO-83SSAQB (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.8 UEF rating across its 83-gallon nominal tank, 121 gal First Hour Rating, standing #268 of 706 across 706 peers with Pass: +1.30 / +52.0% for May 6, 2029. Rated annual electricity draw of 1,313 kWh/yr equates to roughly $238/yr ($2,384 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPS10-80H45DV 2** (3.88 UEF).

Uniform Energy Factor
3.8 UEF
Cohort UEF Rank
#268 of 706 (top 41.9%)
First Hour Rating
121 gal
Storage Volume
83 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.30 / +52.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking SANCO2 GS5-45HPC-D HP + ECO-83SSAQB at 3.8 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50SANCO2 GS5-45HPC-D HP + ECO-83SSAQB: 3.80
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows SANCO2 GS5-45HPC-D HP + ECO-83SSAQB relative to the cohort median.
Efficiency comparison & rule summary

ENERGY STAR certification places SANCO2 GS5-45HPC-D HP + ECO-83SSAQB at 3.8 UEF (#268 of 706; +0.10 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.

May 6, 2029 readiness: SANCO2 GS5-45HPC-D HP + ECO-83SSAQB stands +1.30 UEF (+52.0%) relative to 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,313 kWh/yr for SANCO2 GS5-45HPC-D HP + ECO-83SSAQB runs ~$238/yr vs. ~$985/yr for a 0.92 UEF electric tank. Acoustic output is 37 dBA (quieter than 93.3% of Hybrid/Electric Heat Pump models).

State electric sensitivity for SANCO2 GS5-45HPC-D HP + ECO-83SSAQB: 10-year operating spend spans $1,921 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,195 in Hawaii (Highest EIA State) (47.18 cents/kWh).

In the Hybrid/Electric Heat Pump tier, A. O. Smith HPS10-80H45DV 2** (3.88 UEF, delta +0.08) and American HPS10280H045DV 2** (3.88 UEF, delta +0.08) bracket SANCO2 GS5-45HPC-D HP + ECO-83SSAQB.

Which Specs Set SANCO2 GS5-45HPC-D HP + ECO-83SSAQB Apart From Cohort Averages?

Ranked #268 of 706 (top 41.9%) inside the 706-model Hybrid/Electric Heat Pump cohort, SANCO2 GS5-45HPC-D HP + ECO-83SSAQB is evaluated row by row below against category medians.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandSANCO26 certified listingsENERGY STAR PD 3624318
Model NumberGS5-45HPC-D HP + ECO-83SSAQBDraw pattern: High-UsageGS5-45HPC-D HP + ECO-83SSAQB
Uniform Energy Factor (UEF)3.8+0.10 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)121 gal+49 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,313 kWh/yr+241 kWh/yr vs. 1,072 kWh/yr medianEst. $238/yr @ $0.1816/kWh (EIA US Avg)
Electrical Circuit Requirements230 V / 7 A maxVerify rating plate electrical drawNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-744 (CO₂) (GWP:1 | Lower GWP)Lower-GWP refrigerant alignment (EPA AIM Act)EPA AIM Act Compliance
Sound Pressure Level37 dBAtop 6.7% · quieter than 93.3% of Hybrid/Electric Heat Pump models · -12 dBA vs. 49 dBA medianIndoor placement check
Certification Date2024-08-21Certified 2024-08-21Markets: United States, Canada

How Do Regional kWh Prices Impact GS5-45HPC-D HP + ECO-83SSAQB Over 10 Years?

Using EIA Table 5.6.A benchmarks, SANCO2 GS5-45HPC-D HP + ECO-83SSAQB's 1,313 kWh/yr draw translates to roughly $238/yr on typical US residential bills.

Estimated Annual Electricity Cost by State Rate (1,313 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$238.00/yrHawaii$619.00/yrCalifornia$391.00/yrTexas$209.00/yrWashington$192.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $238/yr $2,384 $7,464
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $619/yr $6,195 $19,391
California 29.75 ¢/kWh ($0.2975) $391/yr $3,906 $12,227
Texas 15.91 ¢/kWh ($0.1591) $209/yr $2,089 $6,539
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $192/yr $1,921 $6,013
Estimated electricity spend (1,313 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

What Should SANCO2 Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC recall sweep recorded zero brand matches for SANCO2; run a quick serial-number check to verify age before replacing wear parts. See Serial Number Lookup.

How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?

Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith HPS10-80H45DV 2** Hybrid/Electric Heat Pump 82 gal 95 gal 3.88 (+0.08) 1,279
American HPS10280H045DV 2** Hybrid/Electric Heat Pump 82 gal 95 gal 3.88 (+0.08) 1,279
Lochinvar HPSA080KD 2** Hybrid/Electric Heat Pump 82 gal 95 gal 3.88 (+0.08) 1,279
RELIANCE WATER HEATERS 10-80-DHPTS 2** Hybrid/Electric Heat Pump 82 gal 95 gal 3.88 (+0.08) 1,279
A. O. Smith HPSN10-80H45DV 2** Hybrid/Electric Heat Pump 82 gal 95 gal 3.88 (+0.08) 1,279

When Should Homeowners Skip SANCO2 GS5-45HPC-D HP + ECO-83SSAQB (Hybrid/Electric Heat Pump)?

Check SANCO2 GS5-45HPC-D HP + ECO-83SSAQB's mechanical constraints—including utility space, Electric capacity, and Pass: +1.30 / +52.0% status—against typical residential installations.

Key Limitations & Exclusions

  • SANCO2 GS5-45HPC-D HP + ECO-83SSAQB needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 37 dBA; avoid mounting SANCO2 GS5-45HPC-D HP + ECO-83SSAQB directly beside quiet bedrooms.
  • Requires condensate drain routing and 230V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing SANCO2 GS5-45HPC-D HP + ECO-83SSAQB Strong Fit — 3.8 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare A. O. Smith HPS10-80H45DV 2** footprint.

Frequently Asked Technical Questions: SANCO2 GS5-45HPC-D HP + ECO-83SSAQB

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Will SANCO2 GS5-45HPC-D HP + ECO-83SSAQB stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 3.8 UEF, SANCO2 GS5-45HPC-D HP + ECO-83SSAQB shows Pass: +1.30 / +52.0% relative to May 6, 2029 federal DOE limits while placing #268 of 706 (top 41.9%) among 706 Hybrid/Electric Heat Pump peers like A. O. Smith HPS10-80H45DV 2**.

Will SANCO2 GS5-45HPC-D HP + ECO-83SSAQB fit through a standard utility door and 72-inch basement ceiling?

Using a wall-mounted hybrid/electric heat pump chassis, SANCO2 GS5-45HPC-D HP + ECO-83SSAQB eliminates floor-tank footprint (wall-hung / compact envelope), though Category IV exhaust and drain clearance remain mandatory.

Do existing utility hookups support SANCO2 GS5-45HPC-D HP + ECO-83SSAQB during replacement?

Electrical specs for SANCO2 GS5-45HPC-D HP + ECO-83SSAQB call for 230V at 7A max (Verify rating plate electrical draw). Have a licensed electrician inspect panel load and wire gauge.

What is the estimated 10-year operating spend for SANCO2 GS5-45HPC-D HP + ECO-83SSAQB?

At 18.16 cents/kWh national residential pricing, SANCO2 GS5-45HPC-D HP + ECO-83SSAQB's 1,313 kWh/yr draw equals roughly $238 annually or $2,380 across a 10-year horizon (ranging from $192/yr in Washington hydro tiers up to $619/yr in Hawaii).

When is SANCO2 GS5-45HPC-D HP + ECO-83SSAQB a poor fit for a residential replacement?

Avoid placing SANCO2 GS5-45HPC-D HP + ECO-83SSAQB directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 37 dBA sound and cool exhaust airflow.

What First Hour Rating or flow capacity does SANCO2 GS5-45HPC-D HP + ECO-83SSAQB deliver?

With 121 gal FHR (+49 gal vs. 72 gal median), SANCO2 GS5-45HPC-D HP + ECO-83SSAQB fits larger 3–5 person homes cleanly.

How do you verify manufacturing age and recall status on SANCO2 GS5-45HPC-D HP + ECO-83SSAQB?

Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for SANCO2; verify exact manufacturing week for SANCO2 GS5-45HPC-D HP + ECO-83SSAQB using the Serial Number Lookup tool.

Does SANCO2 GS5-45HPC-D HP + ECO-83SSAQB qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for SANCO2 GS5-45HPC-D HP + ECO-83SSAQB. Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPS10-80H45DV 2** (3.88 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks