SANCO2 GS5-45HPC HP + ECO-83SSAQB Water Heater Specifications (3.8 UEF)
Engineered as a Electric Hybrid/Electric Heat Pump unit, SANCO2 GS5-45HPC HP + ECO-83SSAQB achieves a certified 3.8 UEF rating across its 83-gallon nominal tank, 121 gal First Hour Rating and ranks #268 of 706 in its 706-model cohort (PD 3624317), recording Pass: +1.30 / +52.0% under 2029 DOE rules. Rated annual electricity draw of 1,313 kWh/yr equates to roughly $238/yr ($2,384 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPS10-80H45DV 2** (3.88 UEF).
- Uniform Energy Factor
- 3.8 UEF
- Cohort UEF Rank
- #268 of 706 (top 41.9%)
- First Hour Rating
- 121 gal
- Storage Volume
- 83 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.30 / +52.0%

Within the 706-unit Hybrid/Electric Heat Pump cohort, SANCO2 GS5-45HPC HP + ECO-83SSAQB logs 3.8 UEF and ranks #268 of 706.
Against 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF), SANCO2 GS5-45HPC HP + ECO-83SSAQB holds a +1.30 UEF (+52.0%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 1,313 kWh/yr for SANCO2 GS5-45HPC HP + ECO-83SSAQB runs ~$238/yr vs. ~$985/yr for a 0.92 UEF electric tank. Acoustic output is 37 dBA (quieter than 93.3% of Hybrid/Electric Heat Pump models).
State electric sensitivity for SANCO2 GS5-45HPC HP + ECO-83SSAQB: 10-year operating spend spans $1,921 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,195 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Cross-shopping SANCO2 GS5-45HPC HP + ECO-83SSAQB (3.8 UEF)? Check A. O. Smith HPS10-80H45DV 2** (3.88 UEF, delta +0.08) and American HPS10280H045DV 2** (3.88 UEF, delta +0.08).
Where Does SANCO2 GS5-45HPC HP + ECO-83SSAQB Rank Against Peer Hybrid/Electric Heat Pump Units?
Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, SANCO2 GS5-45HPC HP + ECO-83SSAQB holds #268 of 706 (top 41.9%); inspect footprint, circuit load, and efficiency deltas here.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | SANCO2 | 6 certified listings | ENERGY STAR PD 3624317 |
| Model Number | GS5-45HPC HP + ECO-83SSAQB | Draw pattern: High-Usage | GS5-45HPC HP + ECO-83SSAQB |
| Uniform Energy Factor (UEF) | 3.8 | +0.10 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 121 gal | +49 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,313 kWh/yr | +241 kWh/yr vs. 1,072 kWh/yr median | Est. $238/yr @ $0.1816/kWh (EIA US Avg) |
| Electrical Circuit Requirements | 230 V / 7 A max | Verify rating plate electrical draw | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-744 (CO₂) (GWP:1 | Lower GWP) | Lower-GWP refrigerant alignment (EPA AIM Act) | EPA AIM Act Compliance |
| Sound Pressure Level | 37 dBA | top 6.7% · quieter than 93.3% of Hybrid/Electric Heat Pump models · -12 dBA vs. 49 dBA median | Indoor placement check |
| Certification Date | 2024-08-21 | Certified 2024-08-21 | Markets: United States, Canada |
How Much Electricity Does GS5-45HPC HP + ECO-83SSAQB Use in Different States?
Estimated at $238/yr nationally (1,313 kWh/yr), 10-year utility spending for SANCO2 GS5-45HPC HP + ECO-83SSAQB shifts sharply between low-rate hydro and coastal grids.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $238/yr | $2,384 | $7,464 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $619/yr | $6,195 | $19,391 |
| California | 29.75 ¢/kWh ($0.2975) | $391/yr | $3,906 | $12,227 |
| Texas | 15.91 ¢/kWh ($0.1591) | $209/yr | $2,089 | $6,539 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $192/yr | $1,921 | $6,013 |
Does CPSC Flag Any Safety Notices on SANCO2 Units?
No open CPSC recall alerts appeared for SANCO2 as of 2026-11-23; you can still decode exact manufacture month and warranty window below. See Serial Number Lookup.
Which Competing Hybrid/Electric Heat Pump Models Compare Closest to GS5-45HPC HP + ECO-83SSAQB?
Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to SANCO2 GS5-45HPC HP + ECO-83SSAQB's gallon capacity and 3.8 UEF efficiency.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| A. O. Smith HPS10-80H45DV 2** | Hybrid/Electric Heat Pump | 82 gal | 95 gal | 3.88 (+0.08) | 1,279 |
| American HPS10280H045DV 2** | Hybrid/Electric Heat Pump | 82 gal | 95 gal | 3.88 (+0.08) | 1,279 |
| Lochinvar HPSA080KD 2** | Hybrid/Electric Heat Pump | 82 gal | 95 gal | 3.88 (+0.08) | 1,279 |
| RELIANCE WATER HEATERS 10-80-DHPTS 2** | Hybrid/Electric Heat Pump | 82 gal | 95 gal | 3.88 (+0.08) | 1,279 |
| A. O. Smith HPSN10-80H45DV 2** | Hybrid/Electric Heat Pump | 82 gal | 95 gal | 3.88 (+0.08) | 1,279 |
What Are the Limitations of SANCO2 GS5-45HPC HP + ECO-83SSAQB and Who Should Not Install It?
Before ordering SANCO2 GS5-45HPC HP + ECO-83SSAQB (Hybrid/Electric Heat Pump, 3.8 UEF), weigh space clearances, fuel piping, noise (37 dBA), and 2029 rule readiness across three scenarios.
Key Limitations & Exclusions
- SANCO2 GS5-45HPC HP + ECO-83SSAQB needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 37 dBA; avoid mounting SANCO2 GS5-45HPC HP + ECO-83SSAQB directly beside quiet bedrooms.
- Requires condensate drain routing and 230V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Common Homeowner Questions for SANCO2 GS5-45HPC HP + ECO-83SSAQB
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Does SANCO2 GS5-45HPC HP + ECO-83SSAQB pass the May 6, 2029 federal DOE efficiency rule?
SANCO2 GS5-45HPC HP + ECO-83SSAQB carries a verified 3.8 UEF rating (Pass: +1.30 / +52.0%), ranking #268 of 706 (top 41.9%) across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.
What doorway width and ceiling height does SANCO2 GS5-45HPC HP + ECO-83SSAQB need?
SANCO2 GS5-45HPC HP + ECO-83SSAQB mounts as a hybrid/electric heat pump without a bulky floor tank (wall-hung / compact envelope). Verify vent termination distances and combustion air clearances per IPC or UPC.
What gas pipe size or electrical breaker does SANCO2 GS5-45HPC HP + ECO-83SSAQB require?
SANCO2 GS5-45HPC HP + ECO-83SSAQB uses a 230V branch circuit at 7A max (Verify rating plate electrical draw). Verify main breaker space before replacing a gas tank with an electric hybrid unit.
How much electricity or energy does SANCO2 GS5-45HPC HP + ECO-83SSAQB cost per year to run?
Rated at 1,313 kWh/yr, SANCO2 GS5-45HPC HP + ECO-83SSAQB costs about $238/yr ($2,380 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $192/yr in Washington hydro tiers up to $619/yr in Hawaii).
Who should NOT install SANCO2 GS5-45HPC HP + ECO-83SSAQB, and what are its limits?
SANCO2 GS5-45HPC HP + ECO-83SSAQB (3.8 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 37 dBA.
How many bathrooms or people can SANCO2 GS5-45HPC HP + ECO-83SSAQB serve at peak demand?
SANCO2 GS5-45HPC HP + ECO-83SSAQB achieves a 121 gal First Hour Rating (+49 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.
Are there CPSC safety recalls or serial checks for SANCO2 GS5-45HPC HP + ECO-83SSAQB?
No active CPSC recalls matched SANCO2 as of 2026-11-23. Always decode the serial tag on SANCO2 GS5-45HPC HP + ECO-83SSAQB because OEM tank/exchanger warranties span 6–12 years.
What 2026 rebates apply to SANCO2 GS5-45HPC HP + ECO-83SSAQB, and what peer compares closest?
Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPS10-80H45DV 2** (3.88 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)