Skip to main content
ENERGY STAR water heater model · PD 4529465

State SHPCO-45 1**+SXST-50S 1** Water Heater Specifications (3.52 UEF)

The State SHPCO-45 1**+SXST-50S 1** (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.52 UEF rating across its 46-gallon nominal tank, 70 gal First Hour Rating, ranking #441 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 4529465). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +1.22 / +53.0%. Rated annual electricity draw of 923 kWh/yr equates to roughly $168/yr ($1,676 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPACO-45 1**+AXST-50S 1** (3.52 UEF).

Uniform Energy Factor
3.52 UEF
Cohort UEF Rank
#441 of 706
First Hour Rating
70 gal
Storage Volume
46 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.22 / +53.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking State SHPCO-45 1**+SXST-50S 1** at 3.52 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30State SHPCO-45 1**+SXST-50S 1**: 3.52
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows State SHPCO-45 1**+SXST-50S 1** relative to the cohort median.
Efficiency comparison & rule summary

State SHPCO-45 1**+SXST-50S 1** (3.52 UEF) ranks #441 of 706 Hybrid/Electric Heat Pump models — 40-way tie; more efficient than 32% of Hybrid/Electric Heat Pump models, -0.18 UEF below the 3.70 UEF median.

Federal 2029 margin for State SHPCO-45 1**+SXST-50S 1**: +1.22 UEF (+53.0%) vs. 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 923 kWh/yr for State SHPCO-45 1**+SXST-50S 1** runs ~$168/yr vs. ~$641/yr for a 0.92 UEF electric tank.

State electric sensitivity for State SHPCO-45 1**+SXST-50S 1**: 10-year operating spend spans $1,350 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,355 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Peer comparison: State SHPCO-45 1**+SXST-50S 1** (3.52 UEF) compares closely with A. O. Smith HPACO-45 1**+AXST-50S 1** (3.52 UEF, at parity) and American MHPCO-45 1**+MXST-50S 1** (3.52 UEF, at parity).

How Do State SHPCO-45 1**+SXST-50S 1** Specs Compare to Hybrid/Electric Heat Pump Medians?

State SHPCO-45 1**+SXST-50S 1** places #441 of 706 across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandState81 certified listingsENERGY STAR PD 4529465
Model NumberSHPCO-45 1**+SXST-50S 1**Draw pattern: Medium-UsageSHPCO-45 1**+SXST-50S 1**
Uniform Energy Factor (UEF)3.52-0.18 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)70 gal-2 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use923 kWh/yr-149 kWh/yr vs. 1,072 kWh/yr medianEst. $168/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency429%At 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)46.6" H x 18" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 20.2 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-744 (CO₂) (GWP:1 | Lower GWP)Lower-GWP refrigerant alignment (EPA AIM Act)EPA AIM Act Compliance
Certification Date2026-02-25Certified 2026-02-25Markets: United States

What Does SHPCO-45 1**+SXST-50S 1** Cost to Operate Across State Electricity Rates?

At 923 kWh/yr, State SHPCO-45 1**+SXST-50S 1** runs roughly $168/yr on the EIA national average tier under August 2026 Table 5.6.A rates.

Estimated Annual Electricity Cost by State Rate (923 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$168.00/yrHawaii$435.00/yrCalifornia$275.00/yrTexas$147.00/yrWashington$135.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $168/yr $1,676 $4,736
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $435/yr $4,355 $12,305
California 29.75 ¢/kWh ($0.2975) $275/yr $2,746 $7,759
Texas 15.91 ¢/kWh ($0.1591) $147/yr $1,468 $4,149
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $135/yr $1,350 $3,816
Estimated electricity spend (923 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are There Active CPSC Safety Recalls for State Water Heaters?

Our 2026-11-23 CPSC SaferProducts query surfaced 4 brand-level recall notices associated with State; match your serial plate before repair. See Serial Number Lookup.

4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #08241 (2008-04-03): A.O. Smith Recalls Gas Water Heaters Due to Fire and Carbon Monoxide Hazards (CPSC Notice)
  • Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
  • Recall #04128 (2004-04-28): CPSC, White-Rodgers Announce Recall of LP and Convertible Gas Water Heater Temperature Controls (CPSC Notice)

Which Certified Water Heaters Match SHPCO-45 1**+SXST-50S 1** Most Closely?

These 5 competing Hybrid/Electric Heat Pump units sit nearest to State SHPCO-45 1**+SXST-50S 1** by storage capacity and 3.52 UEF rating.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith HPACO-45 1**+AXST-50S 1** Hybrid/Electric Heat Pump 46 gal 70 gal 3.52 (at parity) 923
American MHPCO-45 1**+MXST-50S 1** Hybrid/Electric Heat Pump 46 gal 70 gal 3.52 (at parity) 923
Giant GTHPCO-45 1**+GTXST-50S 1** Hybrid/Electric Heat Pump 46 gal 70 gal 3.52 (at parity) 923
GSW WATER HEATERS GHPCO-45 1**+GXST-50S 1** Hybrid/Electric Heat Pump 46 gal 70 gal 3.52 (at parity) 923
A. O. Smith HPACO-45 1**+AXST-50STTP 1** Hybrid/Electric Heat Pump 46 gal 70 gal 3.52 (at parity) 923

What Installation Caveats Apply Before Buying State SHPCO-45 1**+SXST-50S 1**?

Even high-UEF units like State SHPCO-45 1**+SXST-50S 1** (3.52 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

Key Limitations & Exclusions

  • State SHPCO-45 1**+SXST-50S 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting State SHPCO-45 1**+SXST-50S 1** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing State SHPCO-45 1**+SXST-50S 1** Strong Fit — 3.52 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare A. O. Smith HPACO-45 1**+AXST-50S 1** footprint.

What Are the Key Questions About State SHPCO-45 1**+SXST-50S 1**?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Is State SHPCO-45 1**+SXST-50S 1** eligible for continued manufacture past May 6, 2029?

At 3.52 UEF, State SHPCO-45 1**+SXST-50S 1** achieves Pass: +1.22 / +53.0% for the 2029 DOE standard and stands #441 of 706 against A. O. Smith HPACO-45 1**+AXST-50S 1** and American MHPCO-45 1**+MXST-50S 1**.

How tall and wide is State SHPCO-45 1**+SXST-50S 1**, and what service clearance is needed?

Physical dimensions for State SHPCO-45 1**+SXST-50S 1** are 46.6 in. height and 18 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18" d)); verify stair turns and drain pan width before delivery.

Will State SHPCO-45 1**+SXST-50S 1** require upgrading household electrical panels or gas piping?

State SHPCO-45 1**+SXST-50S 1** draws 240V at 20.2A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.

Is State SHPCO-45 1**+SXST-50S 1** economical to operate at 18.16 cents/kWh US electric rates?

Expect roughly $168/yr ($1,680 over 10 years) to power State SHPCO-45 1**+SXST-50S 1** at 923 kWh/yr under the 18.16 cents/kWh US average (ranging from $135/yr in Washington hydro tiers up to $435/yr in Hawaii).

Which installation bottlenecks limit State SHPCO-45 1**+SXST-50S 1**?

If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, State SHPCO-45 1**+SXST-50S 1** drops into resistance mode more often.

How does State SHPCO-45 1**+SXST-50S 1** handle simultaneous showers and laundry?

Delivering 70 gal in the first hour (-2 gal vs. 72 gal median), State SHPCO-45 1**+SXST-50S 1** combines 46 gal tank storage with rapid burner/element recovery.

How long is the warranty on State SHPCO-45 1**+SXST-50S 1** and how do you decode its serial?

CPSC SaferProducts records show 4 brand-level recall notices mentioning State as of 2026-11-23, including #19029 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

How do 2026 post-OBBBA rebates affect buying State SHPCO-45 1**+SXST-50S 1**?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPACO-45 1**+AXST-50S 1** (3.52 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks