State SHPCO-45 1**+SXST-50SG 1** Water Heater Specifications (3.52 UEF)
The State SHPCO-45 1**+SXST-50SG 1** (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.52 UEF rating across its 46-gallon nominal tank, 70 gal First Hour Rating, ranking #441 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 4529460). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +1.22 / +53.0%. Rated annual electricity draw of 923 kWh/yr equates to roughly $168/yr ($1,676 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPACO-45 1**+AXST-50S 1** (3.52 UEF).
- Uniform Energy Factor
- 3.52 UEF
- Cohort UEF Rank
- #441 of 706
- First Hour Rating
- 70 gal
- Storage Volume
- 46 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.22 / +53.0%

State SHPCO-45 1**+SXST-50SG 1** (3.52 UEF) ranks #441 of 706 Hybrid/Electric Heat Pump models — 40-way tie; more efficient than 32% of Hybrid/Electric Heat Pump models, -0.18 UEF below the 3.70 UEF median.
Federal 2029 margin for State SHPCO-45 1**+SXST-50SG 1**: +1.22 UEF (+53.0%) vs. 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 923 kWh/yr for State SHPCO-45 1**+SXST-50SG 1** runs ~$168/yr vs. ~$641/yr for a 0.92 UEF electric tank.
State electric sensitivity for State SHPCO-45 1**+SXST-50SG 1**: 10-year operating spend spans $1,350 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,355 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Peer comparison: State SHPCO-45 1**+SXST-50SG 1** (3.52 UEF) compares closely with A. O. Smith HPACO-45 1**+AXST-50S 1** (3.52 UEF, at parity) and American MHPCO-45 1**+MXST-50S 1** (3.52 UEF, at parity).
Where Does State SHPCO-45 1**+SXST-50SG 1** Rank Against Peer Hybrid/Electric Heat Pump Units?
Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, State SHPCO-45 1**+SXST-50SG 1** holds #441 of 706; inspect footprint, circuit load, and efficiency deltas here.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | State | 81 certified listings | ENERGY STAR PD 4529460 |
| Model Number | SHPCO-45 1**+SXST-50SG 1** | Draw pattern: Medium-Usage | SHPCO-45 1**+SXST-50SG 1** |
| Uniform Energy Factor (UEF) | 3.52 | -0.18 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 70 gal | -2 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 923 kWh/yr | -149 kWh/yr vs. 1,072 kWh/yr median | Est. $168/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 429% | At 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 46.6" H x 18" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 20.2 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-744 (CO₂) (GWP:1 | Lower GWP) | Lower-GWP refrigerant alignment (EPA AIM Act) | EPA AIM Act Compliance |
| Certification Date | 2026-02-25 | Certified 2026-02-25 | Markets: United States |
How Much Electricity Does SHPCO-45 1**+SXST-50SG 1** Use in Different States?
Estimated at $168/yr nationally (923 kWh/yr), 10-year utility spending for State SHPCO-45 1**+SXST-50SG 1** shifts sharply between low-rate hydro and coastal grids.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $168/yr | $1,676 | $4,736 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $435/yr | $4,355 | $12,305 |
| California | 29.75 ¢/kWh ($0.2975) | $275/yr | $2,746 | $7,759 |
| Texas | 15.91 ¢/kWh ($0.1591) | $147/yr | $1,468 | $4,149 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $135/yr | $1,350 | $3,816 |
Does CPSC Flag Any Safety Notices on State Units?
Checking 2026-11-23 SaferProducts data shows 4 notices mentioning State; always cross-reference affected serial prefixes before ordering components. See Serial Number Lookup.
- Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
- Recall #08241 (2008-04-03): A.O. Smith Recalls Gas Water Heaters Due to Fire and Carbon Monoxide Hazards (CPSC Notice)
- Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
- Recall #04128 (2004-04-28): CPSC, White-Rodgers Announce Recall of LP and Convertible Gas Water Heater Temperature Controls (CPSC Notice)
Which Competing Hybrid/Electric Heat Pump Models Compare Closest to SHPCO-45 1**+SXST-50SG 1**?
Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to State SHPCO-45 1**+SXST-50SG 1**'s gallon capacity and 3.52 UEF efficiency.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| A. O. Smith HPACO-45 1**+AXST-50S 1** | Hybrid/Electric Heat Pump | 46 gal | 70 gal | 3.52 (at parity) | 923 |
| American MHPCO-45 1**+MXST-50S 1** | Hybrid/Electric Heat Pump | 46 gal | 70 gal | 3.52 (at parity) | 923 |
| Giant GTHPCO-45 1**+GTXST-50S 1** | Hybrid/Electric Heat Pump | 46 gal | 70 gal | 3.52 (at parity) | 923 |
| GSW WATER HEATERS GHPCO-45 1**+GXST-50S 1** | Hybrid/Electric Heat Pump | 46 gal | 70 gal | 3.52 (at parity) | 923 |
| A. O. Smith HPACO-45 1**+AXST-50STTP 1** | Hybrid/Electric Heat Pump | 46 gal | 70 gal | 3.52 (at parity) | 923 |
When Should Homeowners Skip State SHPCO-45 1**+SXST-50SG 1** (Hybrid/Electric Heat Pump)?
Check State SHPCO-45 1**+SXST-50SG 1**'s mechanical constraints—including utility space, Electric capacity, and Pass: +1.22 / +53.0% status—against typical residential installations.
Key Limitations & Exclusions
- State SHPCO-45 1**+SXST-50SG 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting State SHPCO-45 1**+SXST-50SG 1** directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Common Homeowner Questions for State SHPCO-45 1**+SXST-50SG 1**
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Will State SHPCO-45 1**+SXST-50SG 1** stay compliant after the May 6, 2029 DOE standard takes effect?
Tested at 3.52 UEF, State SHPCO-45 1**+SXST-50SG 1** shows Pass: +1.22 / +53.0% relative to May 6, 2029 federal DOE limits while placing #441 of 706 among 706 Hybrid/Electric Heat Pump peers like A. O. Smith HPACO-45 1**+AXST-50S 1**.
Will State SHPCO-45 1**+SXST-50SG 1** fit through a standard utility door and 72-inch basement ceiling?
Measuring 46.6 in. tall by 18 in. diameter, State SHPCO-45 1**+SXST-50SG 1** notes: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18" d). Reserve space above the jacket for T&P piping and anode removal.
Do existing utility hookups support State SHPCO-45 1**+SXST-50SG 1** during replacement?
Electrical specs for State SHPCO-45 1**+SXST-50SG 1** call for 240V at 20.2A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.
What is the estimated 10-year operating spend for State SHPCO-45 1**+SXST-50SG 1**?
At 18.16 cents/kWh national residential pricing, State SHPCO-45 1**+SXST-50SG 1**'s 923 kWh/yr draw equals roughly $168 annually or $1,680 across a 10-year horizon (ranging from $135/yr in Washington hydro tiers up to $435/yr in Hawaii).
When is State SHPCO-45 1**+SXST-50SG 1** a poor fit for a residential replacement?
Avoid placing State SHPCO-45 1**+SXST-50SG 1** directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.
What First Hour Rating or flow capacity does State SHPCO-45 1**+SXST-50SG 1** deliver?
With 70 gal FHR (-2 gal vs. 72 gal median), State SHPCO-45 1**+SXST-50SG 1** fits larger 3–5 person homes cleanly.
How do you verify manufacturing age and recall status on State SHPCO-45 1**+SXST-50SG 1**?
CPSC SaferProducts records show 4 brand-level recall notices mentioning State as of 2026-11-23, including #19029 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
Does State SHPCO-45 1**+SXST-50SG 1** qualify for DOE HEAR incentives after 25C expired?
After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for State SHPCO-45 1**+SXST-50SG 1**. Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPACO-45 1**+AXST-50S 1** (3.52 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)