State SHPCO-45 1**+SXST-50TG 1** Water Heater Specifications (3.52 UEF)
Certified at 3.52 UEF across its 45-gallon nominal tank, 67 gal First Hour Rating, State SHPCO-45 1**+SXST-50TG 1** (Hybrid/Electric Heat Pump, Electric) places #441 of 706 out of 706 ENERGY STAR models (PD 4529451). Its May 6, 2029 10 CFR 430.32 status reads Pass: +1.22 / +53.0%. Rated annual electricity draw of 923 kWh/yr equates to roughly $168/yr ($1,676 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPACO-45 1**+AXST-50T 1** (3.52 UEF).
- Uniform Energy Factor
- 3.52 UEF
- Cohort UEF Rank
- #441 of 706
- First Hour Rating
- 67 gal
- Storage Volume
- 45 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.22 / +53.0%

Tested at 3.52 UEF, State SHPCO-45 1**+SXST-50TG 1** places #441 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (-0.18 UEF vs. 3.70 UEF median).
State SHPCO-45 1**+SXST-50TG 1** clears 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.22 UEF (+53.0% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 923 kWh/yr for State SHPCO-45 1**+SXST-50TG 1** runs ~$168/yr vs. ~$641/yr for a 0.92 UEF electric tank.
State electric sensitivity for State SHPCO-45 1**+SXST-50TG 1**: 10-year operating spend spans $1,350 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,355 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Closest alternatives to State SHPCO-45 1**+SXST-50TG 1** include A. O. Smith HPACO-45 1**+AXST-50T 1** (3.52 UEF, at parity) alongside American MHPCO-45 1**+MXST-50T 1** (3.52 UEF, at parity).
Which Specs Set State SHPCO-45 1**+SXST-50TG 1** Apart From Cohort Averages?
Ranked #441 of 706 inside the 706-model Hybrid/Electric Heat Pump cohort, State SHPCO-45 1**+SXST-50TG 1** is evaluated row by row below against category medians.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | State | 81 certified listings | ENERGY STAR PD 4529451 |
| Model Number | SHPCO-45 1**+SXST-50TG 1** | Draw pattern: Medium-Usage | SHPCO-45 1**+SXST-50TG 1** |
| Uniform Energy Factor (UEF) | 3.52 | -0.18 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 67 gal | -5 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 923 kWh/yr | -149 kWh/yr vs. 1,072 kWh/yr median | Est. $168/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 413% | -16.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 57" H x 16" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (16" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 20.2 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-744 (CO₂) (GWP:1 | Lower GWP) | Lower-GWP refrigerant alignment (EPA AIM Act) | EPA AIM Act Compliance |
| Certification Date | 2026-02-25 | Certified 2026-02-25 | Markets: United States |
How Do Regional kWh Prices Impact SHPCO-45 1**+SXST-50TG 1** Over 10 Years?
Using EIA Table 5.6.A benchmarks, State SHPCO-45 1**+SXST-50TG 1**'s 923 kWh/yr draw translates to roughly $168/yr on typical US residential bills.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $168/yr | $1,676 | $4,736 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $435/yr | $4,355 | $12,305 |
| California | 29.75 ¢/kWh ($0.2975) | $275/yr | $2,746 | $7,759 |
| Texas | 15.91 ¢/kWh ($0.1591) | $147/yr | $1,468 | $4,149 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $135/yr | $1,350 | $3,816 |
What Should State Owners Check in CPSC Recall Logs?
The 2026-11-23 CPSC SaferProducts snapshot includes 4 filings tied to State; verify whether your SHPCO-45 1**+SXST-50TG 1** production run falls inside affected ranges. See Serial Number Lookup.
- Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
- Recall #08241 (2008-04-03): A.O. Smith Recalls Gas Water Heaters Due to Fire and Carbon Monoxide Hazards (CPSC Notice)
- Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
- Recall #04128 (2004-04-28): CPSC, White-Rodgers Announce Recall of LP and Convertible Gas Water Heater Temperature Controls (CPSC Notice)
How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?
Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| A. O. Smith HPACO-45 1**+AXST-50T 1** | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.52 (at parity) | 923 |
| American MHPCO-45 1**+MXST-50T 1** | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.52 (at parity) | 923 |
| Giant GHPCO-45 1**+GXST-50T 1** | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.52 (at parity) | 923 |
| GSW WATER HEATERS GTHPCO-45 1**+GTXST-50T 1** | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.52 (at parity) | 923 |
| A. O. Smith HPACO-45 1**+AXST-50TTTP 1** | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.52 (at parity) | 923 |
What Are the Limitations of State SHPCO-45 1**+SXST-50TG 1** and Who Should Not Install It?
Before ordering State SHPCO-45 1**+SXST-50TG 1** (Hybrid/Electric Heat Pump, 3.52 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.
Key Limitations & Exclusions
- State SHPCO-45 1**+SXST-50TG 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting State SHPCO-45 1**+SXST-50TG 1** directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Frequently Asked Technical Questions: State SHPCO-45 1**+SXST-50TG 1**
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Does State SHPCO-45 1**+SXST-50TG 1** pass the May 6, 2029 federal DOE efficiency rule?
State SHPCO-45 1**+SXST-50TG 1** carries a verified 3.52 UEF rating (Pass: +1.22 / +53.0%), ranking #441 of 706 across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.
What doorway width and ceiling height does State SHPCO-45 1**+SXST-50TG 1** need?
State SHPCO-45 1**+SXST-50TG 1** stands 57 in. high with a 16 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (16" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.
What gas pipe size or electrical breaker does State SHPCO-45 1**+SXST-50TG 1** require?
State SHPCO-45 1**+SXST-50TG 1** uses a 240V branch circuit at 20.2A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.
How much electricity or energy does State SHPCO-45 1**+SXST-50TG 1** cost per year to run?
Rated at 923 kWh/yr, State SHPCO-45 1**+SXST-50TG 1** costs about $168/yr ($1,680 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $135/yr in Washington hydro tiers up to $435/yr in Hawaii).
Who should NOT install State SHPCO-45 1**+SXST-50TG 1**, and what are its limits?
State SHPCO-45 1**+SXST-50TG 1** (3.52 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.
How many bathrooms or people can State SHPCO-45 1**+SXST-50TG 1** serve at peak demand?
State SHPCO-45 1**+SXST-50TG 1** achieves a 67 gal First Hour Rating (-5 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.
Are there CPSC safety recalls or serial checks for State SHPCO-45 1**+SXST-50TG 1**?
CPSC SaferProducts records show 4 brand-level recall notices mentioning State as of 2026-11-23, including #19029 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
What 2026 rebates apply to State SHPCO-45 1**+SXST-50TG 1**, and what peer compares closest?
Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPACO-45 1**+AXST-50T 1** (3.52 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)