State SHPCO-45 1**+SXST-80 1** Water Heater Specifications (3.8 UEF)
In the 706-unit Hybrid/Electric Heat Pump class, State SHPCO-45 1**+SXST-80 1** (Electric) achieves a certified 3.8 UEF rating across its 73-gallon nominal tank, 95 gal First Hour Rating (rank #268 of 706, PD 4529439) and verifies as Pass: +1.30 / +52.0% for 2029 DOE floors. Rated annual electricity draw of 1,306 kWh/yr equates to roughly $237/yr ($2,372 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPACO-45 1**+AXST-80 1** (3.8 UEF).
- Uniform Energy Factor
- 3.8 UEF
- Cohort UEF Rank
- #268 of 706 (top 41.9%)
- First Hour Rating
- 95 gal
- Storage Volume
- 73 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.30 / +52.0%

State SHPCO-45 1**+SXST-80 1** records 3.8 UEF efficiency, putting it #268 of 706 among 706 Hybrid/Electric Heat Pump peers.
10 CFR 430.32(d)(2) compliance: State SHPCO-45 1**+SXST-80 1** exceeds 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +1.30 UEF (+52.0%). At EIA August 2026 national rates (18.16 cents/kWh), 1,306 kWh/yr for State SHPCO-45 1**+SXST-80 1** runs ~$237/yr vs. ~$980/yr for a 0.92 UEF electric tank.
State electric sensitivity for State SHPCO-45 1**+SXST-80 1**: 10-year operating spend spans $1,911 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,162 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Competing options beside State SHPCO-45 1**+SXST-80 1** (3.8 UEF) are A. O. Smith HPACO-45 1**+AXST-80 1** (3.8 UEF, at parity) and American MHPCO-45 1**+MXST-80 1** (3.8 UEF, at parity).
Where Does State SHPCO-45 1**+SXST-80 1** Rank Against Peer Hybrid/Electric Heat Pump Units?
Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, State SHPCO-45 1**+SXST-80 1** holds #268 of 706 (top 41.9%); inspect footprint, circuit load, and efficiency deltas here.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | State | 81 certified listings | ENERGY STAR PD 4529439 |
| Model Number | SHPCO-45 1**+SXST-80 1** | Draw pattern: High-Usage | SHPCO-45 1**+SXST-80 1** |
| Uniform Energy Factor (UEF) | 3.8 | +0.10 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 95 gal | +23 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,306 kWh/yr | +234 kWh/yr vs. 1,072 kWh/yr median | Est. $237/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 423% | -6.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 58" H x 20" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 20.2 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-744 (CO₂) (GWP:1 | Lower GWP) | Lower-GWP refrigerant alignment (EPA AIM Act) | EPA AIM Act Compliance |
| Certification Date | 2026-02-25 | Certified 2026-02-25 | Markets: United States |
How Much Electricity Does SHPCO-45 1**+SXST-80 1** Use in Different States?
Estimated at $237/yr nationally (1,306 kWh/yr), 10-year utility spending for State SHPCO-45 1**+SXST-80 1** shifts sharply between low-rate hydro and coastal grids.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $237/yr | $2,372 | $7,424 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $616/yr | $6,162 | $19,287 |
| California | 29.75 ¢/kWh ($0.2975) | $389/yr | $3,885 | $12,162 |
| Texas | 15.91 ¢/kWh ($0.1591) | $208/yr | $2,078 | $6,504 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $191/yr | $1,911 | $5,981 |
Does CPSC Flag Any Safety Notices on State Units?
Checking 2026-11-23 SaferProducts data shows 4 notices mentioning State; always cross-reference affected serial prefixes before ordering components. See Serial Number Lookup.
- Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
- Recall #08241 (2008-04-03): A.O. Smith Recalls Gas Water Heaters Due to Fire and Carbon Monoxide Hazards (CPSC Notice)
- Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
- Recall #04128 (2004-04-28): CPSC, White-Rodgers Announce Recall of LP and Convertible Gas Water Heater Temperature Controls (CPSC Notice)
Which Competing Hybrid/Electric Heat Pump Models Compare Closest to SHPCO-45 1**+SXST-80 1**?
Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to State SHPCO-45 1**+SXST-80 1**'s gallon capacity and 3.8 UEF efficiency.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| A. O. Smith HPACO-45 1**+AXST-80 1** | Hybrid/Electric Heat Pump | 73 gal | 95 gal | 3.8 (at parity) | 1,306 |
| American MHPCO-45 1**+MXST-80 1** | Hybrid/Electric Heat Pump | 73 gal | 95 gal | 3.8 (at parity) | 1,306 |
| Giant GTHPCO-45 1**+GTXST-80 1** | Hybrid/Electric Heat Pump | 73 gal | 95 gal | 3.8 (at parity) | 1,306 |
| GSW WATER HEATERS GHPCO-45 1**+GXST-80 1** | Hybrid/Electric Heat Pump | 73 gal | 95 gal | 3.8 (at parity) | 1,306 |
| A. O. Smith HPACO-45 1**+AXST-80TTP 1** | Hybrid/Electric Heat Pump | 73 gal | 95 gal | 3.8 (at parity) | 1,306 |
Who Is State SHPCO-45 1**+SXST-80 1** Best For — and When Should You Pick A. O. Smith HPACO-45 1**+AXST-80 1**?
Evaluate whether State SHPCO-45 1**+SXST-80 1**'s Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.
Key Limitations & Exclusions
- State SHPCO-45 1**+SXST-80 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting State SHPCO-45 1**+SXST-80 1** directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Common Homeowner Questions for State SHPCO-45 1**+SXST-80 1**
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
How does State SHPCO-45 1**+SXST-80 1** (3.8 UEF) compare to 2029 federal DOE floors?
Evaluated against May 6, 2029 10 CFR 430.32 thresholds, State SHPCO-45 1**+SXST-80 1** records 3.8 UEF (Pass: +1.30 / +52.0%), placing #268 of 706 (top 41.9%) out of 706 certified Hybrid/Electric Heat Pump configurations.
Does State SHPCO-45 1**+SXST-80 1** fit inside a tight hallway closet or low-headroom utility room?
State SHPCO-45 1**+SXST-80 1** requires room for its 58 in. vertical shell and 20 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20" d)), plus service access for annual sediment draining.
What power supply or fuel line specs govern State SHPCO-45 1**+SXST-80 1**?
For State SHPCO-45 1**+SXST-80 1**, plan a 240V circuit at 20.2A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.
What annual utility bill should homeowners budget for State SHPCO-45 1**+SXST-80 1**?
Using 1,306 kWh/yr, State SHPCO-45 1**+SXST-80 1** generates an estimated $237/yr electric bill at 18.16 cents/kWh (ranging from $191/yr in Washington hydro tiers up to $616/yr in Hawaii)—use the custom rate slider above for your utility tariff.
What are the main drawbacks of State SHPCO-45 1**+SXST-80 1** (3.8 UEF)?
State SHPCO-45 1**+SXST-80 1** requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or A. O. Smith HPACO-45 1**+AXST-80 1**.
What hot-water delivery rating governs State SHPCO-45 1**+SXST-80 1**?
Rated for 95 gal FHR (+23 gal vs. 72 gal median), State SHPCO-45 1**+SXST-80 1** prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.
Where do homeowners screen State SHPCO-45 1**+SXST-80 1** for recalls and tank age?
CPSC SaferProducts records show 4 brand-level recall notices mentioning State as of 2026-11-23, including #19029 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
What alternative models sit closest to State SHPCO-45 1**+SXST-80 1** in the Hybrid/Electric Heat Pump class?
Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPACO-45 1**+AXST-80 1** (3.8 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)