Skip to main content
ENERGY STAR water heater model · PD 4529434

State SHPCO-45 1**+SXST-80G 1** Water Heater Specifications (3.8 UEF)

In the 706-unit Hybrid/Electric Heat Pump class, State SHPCO-45 1**+SXST-80G 1** (Electric) achieves a certified 3.8 UEF rating across its 73-gallon nominal tank, 95 gal First Hour Rating (rank #268 of 706, PD 4529434) and verifies as Pass: +1.30 / +52.0% for 2029 DOE floors. Rated annual electricity draw of 1,306 kWh/yr equates to roughly $237/yr ($2,372 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPACO-45 1**+AXST-80 1** (3.8 UEF).

Uniform Energy Factor
3.8 UEF
Cohort UEF Rank
#268 of 706 (top 41.9%)
First Hour Rating
95 gal
Storage Volume
73 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.30 / +52.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking State SHPCO-45 1**+SXST-80G 1** at 3.8 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50State SHPCO-45 1**+SXST-80G 1**: 3.80
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows State SHPCO-45 1**+SXST-80G 1** relative to the cohort median.
Efficiency comparison & rule summary

State SHPCO-45 1**+SXST-80G 1** records 3.8 UEF efficiency, putting it #268 of 706 among 706 Hybrid/Electric Heat Pump peers.

10 CFR 430.32(d)(2) compliance: State SHPCO-45 1**+SXST-80G 1** exceeds 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +1.30 UEF (+52.0%). At EIA August 2026 national rates (18.16 cents/kWh), 1,306 kWh/yr for State SHPCO-45 1**+SXST-80G 1** runs ~$237/yr vs. ~$980/yr for a 0.92 UEF electric tank.

State electric sensitivity for State SHPCO-45 1**+SXST-80G 1**: 10-year operating spend spans $1,911 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,162 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Competing options beside State SHPCO-45 1**+SXST-80G 1** (3.8 UEF) are A. O. Smith HPACO-45 1**+AXST-80 1** (3.8 UEF, at parity) and American MHPCO-45 1**+MXST-80 1** (3.8 UEF, at parity).

What Physical and Thermal Ratings Define State SHPCO-45 1**+SXST-80G 1**?

Positioning at #268 of 706 (top 41.9%) out of 706 Hybrid/Electric Heat Pump peers, State SHPCO-45 1**+SXST-80G 1** pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandState81 certified listingsENERGY STAR PD 4529434
Model NumberSHPCO-45 1**+SXST-80G 1**Draw pattern: High-UsageSHPCO-45 1**+SXST-80G 1**
Uniform Energy Factor (UEF)3.8+0.10 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)95 gal+23 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,306 kWh/yr+234 kWh/yr vs. 1,072 kWh/yr medianEst. $237/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency423%-6.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)58" H x 20" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 20.2 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-744 (CO₂) (GWP:1 | Lower GWP)Lower-GWP refrigerant alignment (EPA AIM Act)EPA AIM Act Compliance
Certification Date2026-02-25Certified 2026-02-25Markets: United States

Why Do State Utility Rates Shift SHPCO-45 1**+SXST-80G 1** Running Costs?

Consuming 1,306 kWh annually puts State SHPCO-45 1**+SXST-80G 1** near $237/yr at US baseline tariffs, with multi-state EIA comparisons charted below.

Estimated Annual Electricity Cost by State Rate (1,306 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$237.00/yrHawaii$616.00/yrCalifornia$389.00/yrTexas$208.00/yrWashington$191.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $237/yr $2,372 $7,424
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $616/yr $6,162 $19,287
California 29.75 ¢/kWh ($0.2975) $389/yr $3,885 $12,162
Texas 15.91 ¢/kWh ($0.1591) $208/yr $2,078 $6,504
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $191/yr $1,911 $5,981
Estimated electricity spend (1,306 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Have Any State Series Triggered CPSC Recalls?

SaferProducts records retrieved 2026-11-23 list 4 brand notices under State; inspect model coverage dates prior to valve or anode service. See Serial Number Lookup.

4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #08241 (2008-04-03): A.O. Smith Recalls Gas Water Heaters Due to Fire and Carbon Monoxide Hazards (CPSC Notice)
  • Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
  • Recall #04128 (2004-04-28): CPSC, White-Rodgers Announce Recall of LP and Convertible Gas Water Heater Temperature Controls (CPSC Notice)

What Are 5 Direct Alternatives to State SHPCO-45 1**+SXST-80G 1**?

Homeowners cross-shopping State SHPCO-45 1**+SXST-80G 1** frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith HPACO-45 1**+AXST-80 1** Hybrid/Electric Heat Pump 73 gal 95 gal 3.8 (at parity) 1,306
American MHPCO-45 1**+MXST-80 1** Hybrid/Electric Heat Pump 73 gal 95 gal 3.8 (at parity) 1,306
Giant GTHPCO-45 1**+GTXST-80 1** Hybrid/Electric Heat Pump 73 gal 95 gal 3.8 (at parity) 1,306
GSW WATER HEATERS GHPCO-45 1**+GXST-80 1** Hybrid/Electric Heat Pump 73 gal 95 gal 3.8 (at parity) 1,306
A. O. Smith HPACO-45 1**+AXST-80TTP 1** Hybrid/Electric Heat Pump 73 gal 95 gal 3.8 (at parity) 1,306

Which Home Setups Are NOT a Fit for State SHPCO-45 1**+SXST-80G 1**?

Comparing State SHPCO-45 1**+SXST-80G 1** against A. O. Smith HPACO-45 1**+AXST-80 1** requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

Key Limitations & Exclusions

  • State SHPCO-45 1**+SXST-80G 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting State SHPCO-45 1**+SXST-80G 1** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing State SHPCO-45 1**+SXST-80G 1** Strong Fit — 3.8 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare A. O. Smith HPACO-45 1**+AXST-80 1** footprint.

Sizing, Efficiency & Recall Answers for State SHPCO-45 1**+SXST-80G 1**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does State SHPCO-45 1**+SXST-80G 1** score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; State SHPCO-45 1**+SXST-80G 1** logs 3.8 UEF (Pass: +1.30 / +52.0%) within the 706-unit Hybrid/Electric Heat Pump group.

What physical clearance dimensions apply when installing State SHPCO-45 1**+SXST-80G 1**?

With a 58 in. height and 20 in. diameter, State SHPCO-45 1**+SXST-80G 1** fits spaces matching: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20" d), plus 6–12 in. above for plumbing shutoffs.

What 240V circuit or IFGC fuel line capacity fits State SHPCO-45 1**+SXST-80G 1**?

Powered via 240V at 20.2A max, State SHPCO-45 1**+SXST-80G 1** requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.

How do state electricity prices change annual costs for State SHPCO-45 1**+SXST-80G 1**?

Annual electric spend for State SHPCO-45 1**+SXST-80G 1** (1,306 kWh/yr) averages $237/yr nationwide (ranging from $191/yr in Washington hydro tiers up to $616/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.

What homeowner setups should avoid choosing State SHPCO-45 1**+SXST-80G 1**?

Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on State SHPCO-45 1**+SXST-80G 1**.

Is State SHPCO-45 1**+SXST-80G 1** sized adequately for a 2-to-4-person household?

ENERGY STAR certifies State SHPCO-45 1**+SXST-80G 1** at 95 gal First Hour Rating (+23 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.

Does State have active CPSC SaferProducts notices affecting SHPCO-45 1**+SXST-80G 1**?

CPSC SaferProducts records show 4 brand-level recall notices mentioning State as of 2026-11-23, including #19029 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

Which competing water heater matches State SHPCO-45 1**+SXST-80G 1** (3.8 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for State SHPCO-45 1**+SXST-80G 1**. Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPACO-45 1**+AXST-80 1** (3.8 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks