Skip to main content
ENERGY STAR water heater model · PD 2408885

U.S. Craftmaster HPHE2K50HD045VUN 1** Water Heater Specifications (3.45 UEF)

The U.S. Craftmaster HPHE2K50HD045VUN 1** (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.45 UEF rating across its 46-gallon nominal tank, 66 gal First Hour Rating, ranking #563 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 2408885). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +1.15 / +50.0%. Rated annual electricity draw of 902 kWh/yr equates to roughly $164/yr ($1,638 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HP1050H45DV 1** (3.45 UEF).

Uniform Energy Factor
3.45 UEF
Cohort UEF Rank
#563 of 706
First Hour Rating
66 gal
Storage Volume
46 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.15 / +50.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking U.S. Craftmaster HPHE2K50HD045VUN 1** at 3.45 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30U.S. Craftmaster HPHE2K50HD045VUN 1**: 3.45
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows U.S. Craftmaster HPHE2K50HD045VUN 1** relative to the cohort median.
Efficiency comparison & rule summary

U.S. Craftmaster HPHE2K50HD045VUN 1** (3.45 UEF) ranks #563 of 706 Hybrid/Electric Heat Pump models — 59-way tie; more efficient than 12% of Hybrid/Electric Heat Pump models, -0.25 UEF below the 3.70 UEF median.

Federal 2029 margin for U.S. Craftmaster HPHE2K50HD045VUN 1**: +1.15 UEF (+50.0%) vs. 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 902 kWh/yr for U.S. Craftmaster HPHE2K50HD045VUN 1** runs ~$164/yr vs. ~$614/yr for a 0.92 UEF electric tank.

State electric sensitivity for U.S. Craftmaster HPHE2K50HD045VUN 1**: 10-year operating spend spans $1,320 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,256 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Peer comparison: U.S. Craftmaster HPHE2K50HD045VUN 1** (3.45 UEF) compares closely with A. O. Smith HP1050H45DV 1** (3.45 UEF, at parity) and American HPHE10250H045DVCTA-1** (3.45 UEF, at parity).

What Physical and Thermal Ratings Define U.S. Craftmaster HPHE2K50HD045VUN 1**?

Positioning at #563 of 706 out of 706 Hybrid/Electric Heat Pump peers, U.S. Craftmaster HPHE2K50HD045VUN 1** pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandU.S. Craftmaster6 certified listingsENERGY STAR PD 2408885
Model NumberHPHE2K50HD045VUN 1**Draw pattern: Medium-UsageHPHE2K50HD045VUN 1**
Uniform Energy Factor (UEF)3.45-0.25 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)66 gal-6 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use902 kWh/yr-170 kWh/yr vs. 1,072 kWh/yr medianEst. $164/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency407%-22.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)63" H x 15" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (15" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 22 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2023-02-23Certified 2023-02-23Markets: United States, Canada

Why Do State Utility Rates Shift HPHE2K50HD045VUN 1** Running Costs?

Consuming 902 kWh annually puts U.S. Craftmaster HPHE2K50HD045VUN 1** near $164/yr at US baseline tariffs, with multi-state EIA comparisons charted below.

Estimated Annual Electricity Cost by State Rate (902 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$164.00/yrHawaii$426.00/yrCalifornia$268.00/yrTexas$144.00/yrWashington$132.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $164/yr $1,638 $4,504
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $426/yr $4,256 $11,701
California 29.75 ¢/kWh ($0.2975) $268/yr $2,683 $7,378
Texas 15.91 ¢/kWh ($0.1591) $144/yr $1,435 $3,946
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $132/yr $1,320 $3,628
Estimated electricity spend (902 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Have Any U.S. Craftmaster Series Triggered CPSC Recalls?

SaferProducts screening on 2026-11-23 returned zero recall matches for U.S. Craftmaster; confirm tank age separately using the rating-plate serial pattern. See Serial Number Lookup.

What Are 5 Direct Alternatives to U.S. Craftmaster HPHE2K50HD045VUN 1**?

Homeowners cross-shopping U.S. Craftmaster HPHE2K50HD045VUN 1** frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith HP1050H45DV 1** Hybrid/Electric Heat Pump 46 gal 66 gal 3.45 (at parity) 902
American HPHE10250H045DVCTA-1** Hybrid/Electric Heat Pump 46 gal 66 gal 3.45 (at parity) 902
Lochinvar HPA052KD 1** Hybrid/Electric Heat Pump 46 gal 66 gal 3.45 (at parity) 902
RELIANCE WATER HEATERS 10-50-DHPHTCTA 1** Hybrid/Electric Heat Pump 46 gal 66 gal 3.45 (at parity) 902
A. O. Smith HP1050H45DVCTA-1** Hybrid/Electric Heat Pump 46 gal 66 gal 3.45 (at parity) 902

Which Home Setups Are NOT a Fit for U.S. Craftmaster HPHE2K50HD045VUN 1**?

Comparing U.S. Craftmaster HPHE2K50HD045VUN 1** against A. O. Smith HP1050H45DV 1** requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

Key Limitations & Exclusions

  • U.S. Craftmaster HPHE2K50HD045VUN 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting U.S. Craftmaster HPHE2K50HD045VUN 1** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing U.S. Craftmaster HPHE2K50HD045VUN 1** Strong Fit — 3.45 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare A. O. Smith HP1050H45DV 1** footprint.

Sizing, Efficiency & Recall Answers for U.S. Craftmaster HPHE2K50HD045VUN 1**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does U.S. Craftmaster HPHE2K50HD045VUN 1** score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; U.S. Craftmaster HPHE2K50HD045VUN 1** logs 3.45 UEF (Pass: +1.15 / +50.0%) within the 706-unit Hybrid/Electric Heat Pump group.

What physical clearance dimensions apply when installing U.S. Craftmaster HPHE2K50HD045VUN 1**?

With a 63 in. height and 15 in. diameter, U.S. Craftmaster HPHE2K50HD045VUN 1** fits spaces matching: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (15" d), plus 6–12 in. above for plumbing shutoffs.

What 240V circuit or IFGC fuel line capacity fits U.S. Craftmaster HPHE2K50HD045VUN 1**?

Powered via 240V at 22A max, U.S. Craftmaster HPHE2K50HD045VUN 1** requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.

How do state electricity prices change annual costs for U.S. Craftmaster HPHE2K50HD045VUN 1**?

Annual electric spend for U.S. Craftmaster HPHE2K50HD045VUN 1** (902 kWh/yr) averages $164/yr nationwide (ranging from $132/yr in Washington hydro tiers up to $426/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.

What homeowner setups should avoid choosing U.S. Craftmaster HPHE2K50HD045VUN 1**?

Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on U.S. Craftmaster HPHE2K50HD045VUN 1**.

Is U.S. Craftmaster HPHE2K50HD045VUN 1** sized adequately for a 2-to-4-person household?

ENERGY STAR certifies U.S. Craftmaster HPHE2K50HD045VUN 1** at 66 gal First Hour Rating (-6 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.

Does U.S. Craftmaster have active CPSC SaferProducts notices affecting HPHE2K50HD045VUN 1**?

Zero CPSC recall alerts matched U.S. Craftmaster (2026-11-23 check). Keep your U.S. Craftmaster HPHE2K50HD045VUN 1** serial code handy to track standard 6-to-12-year OEM warranty coverage.

Which competing water heater matches U.S. Craftmaster HPHE2K50HD045VUN 1** (3.45 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for U.S. Craftmaster HPHE2K50HD045VUN 1**. Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HP1050H45DV 1** (3.45 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks