Skip to main content
ENERGY STAR water heater model · PD 2408860

U.S. Craftmaster HPHE2K80HD045VUN 1** Water Heater Specifications (3.45 UEF)

The U.S. Craftmaster HPHE2K80HD045VUN 1** (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.45 UEF rating across its 82-gallon nominal tank, 86 gal First Hour Rating, ranking #563 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 2408860). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +0.95 / +38.0%. Rated annual electricity draw of 1,387 kWh/yr equates to roughly $252/yr ($2,519 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HP1080H45DV 1** (3.45 UEF).

Uniform Energy Factor
3.45 UEF
Cohort UEF Rank
#563 of 706
First Hour Rating
86 gal
Storage Volume
82 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +0.95 / +38.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking U.S. Craftmaster HPHE2K80HD045VUN 1** at 3.45 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50U.S. Craftmaster HPHE2K80HD045VUN 1**: 3.45
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows U.S. Craftmaster HPHE2K80HD045VUN 1** relative to the cohort median.
Efficiency comparison & rule summary

U.S. Craftmaster HPHE2K80HD045VUN 1** (3.45 UEF) ranks #563 of 706 Hybrid/Electric Heat Pump models — 59-way tie; more efficient than 12% of Hybrid/Electric Heat Pump models, -0.25 UEF below the 3.70 UEF median.

Federal 2029 margin for U.S. Craftmaster HPHE2K80HD045VUN 1**: +0.95 UEF (+38.0%) vs. 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,387 kWh/yr for U.S. Craftmaster HPHE2K80HD045VUN 1** runs ~$252/yr vs. ~$945/yr for a 0.92 UEF electric tank.

State electric sensitivity for U.S. Craftmaster HPHE2K80HD045VUN 1**: 10-year operating spend spans $2,029 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,544 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Peer comparison: U.S. Craftmaster HPHE2K80HD045VUN 1** (3.45 UEF) compares closely with A. O. Smith HP1080H45DV 1** (3.45 UEF, at parity) and American HPHE10280H045DVCTA-1** (3.45 UEF, at parity).

How Complete Are the Certified Metrics for U.S. Craftmaster HPHE2K80HD045VUN 1**?

Standing at #563 of 706 among 706 certified Hybrid/Electric Heat Pump heaters, U.S. Craftmaster HPHE2K80HD045VUN 1** brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandU.S. Craftmaster6 certified listingsENERGY STAR PD 2408860
Model NumberHPHE2K80HD045VUN 1**Draw pattern: High-UsageHPHE2K80HD045VUN 1**
Uniform Energy Factor (UEF)3.45-0.25 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)86 gal+14 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,387 kWh/yr+315 kWh/yr vs. 1,072 kWh/yr medianEst. $252/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency233%-196.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)69" H x 27" DVerify 72 in. vertical headroom; tight at 28 in. door (27" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 22 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2023-02-23Certified 2023-02-23Markets: United States, Canada

What Is the Projected Utility Bill for HPHE2K80HD045VUN 1** by State?

At 1,387 kWh/yr, U.S. Craftmaster HPHE2K80HD045VUN 1** averages about $252/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.

Estimated Annual Electricity Cost by State Rate (1,387 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$252.00/yrHawaii$654.00/yrCalifornia$413.00/yrTexas$221.00/yrWashington$203.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $252/yr $2,519 $6,926
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $654/yr $6,544 $17,994
California 29.75 ¢/kWh ($0.2975) $413/yr $4,126 $11,347
Texas 15.91 ¢/kWh ($0.1591) $221/yr $2,207 $6,068
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $203/yr $2,029 $5,580
Estimated electricity spend (1,387 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are U.S. Craftmaster Models Affected by Current CPSC Notices?

Zero brand-level CPSC hazard notices matched U.S. Craftmaster in our 2026-11-23 feed; decode your water heater's serial number below to confirm warranty status. See Serial Number Lookup.

Which 5 Models Offer Similar Output to HPHE2K80HD045VUN 1**?

Ordered by minimal capacity and UEF spread relative to U.S. Craftmaster HPHE2K80HD045VUN 1**, these five certified peers give direct replacement benchmarks.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith HP1080H45DV 1** Hybrid/Electric Heat Pump 82 gal 86 gal 3.45 (at parity) 1,387
American HPHE10280H045DVCTA-1** Hybrid/Electric Heat Pump 82 gal 86 gal 3.45 (at parity) 1,387
Lochinvar HPA082KD 1** Hybrid/Electric Heat Pump 82 gal 86 gal 3.45 (at parity) 1,387
RELIANCE WATER HEATERS 10-80-DHPHTCTA 1** Hybrid/Electric Heat Pump 82 gal 86 gal 3.45 (at parity) 1,387
A. O. Smith HP1080H45DVCTA-1** Hybrid/Electric Heat Pump 82 gal 86 gal 3.45 (at parity) 1,387

When Should Homeowners Skip U.S. Craftmaster HPHE2K80HD045VUN 1** (Hybrid/Electric Heat Pump)?

Check U.S. Craftmaster HPHE2K80HD045VUN 1**'s mechanical constraints—including utility space, Electric capacity, and Pass: +0.95 / +38.0% status—against typical residential installations.

Key Limitations & Exclusions

  • U.S. Craftmaster HPHE2K80HD045VUN 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting U.S. Craftmaster HPHE2K80HD045VUN 1** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing U.S. Craftmaster HPHE2K80HD045VUN 1** Strong Fit — 3.45 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare A. O. Smith HP1080H45DV 1** footprint.

Practical Specs & Code Questions for U.S. Craftmaster HPHE2K80HD045VUN 1**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Will U.S. Craftmaster HPHE2K80HD045VUN 1** stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 3.45 UEF, U.S. Craftmaster HPHE2K80HD045VUN 1** shows Pass: +0.95 / +38.0% relative to May 6, 2029 federal DOE limits while placing #563 of 706 among 706 Hybrid/Electric Heat Pump peers like A. O. Smith HP1080H45DV 1**.

Will U.S. Craftmaster HPHE2K80HD045VUN 1** fit through a standard utility door and 72-inch basement ceiling?

Measuring 69 in. tall by 27 in. diameter, U.S. Craftmaster HPHE2K80HD045VUN 1** notes: verify 72 in. vertical headroom; tight at 28 in. door (27" d). Reserve space above the jacket for T&P piping and anode removal.

Do existing utility hookups support U.S. Craftmaster HPHE2K80HD045VUN 1** during replacement?

Electrical specs for U.S. Craftmaster HPHE2K80HD045VUN 1** call for 240V at 22A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.

What is the estimated 10-year operating spend for U.S. Craftmaster HPHE2K80HD045VUN 1**?

At 18.16 cents/kWh national residential pricing, U.S. Craftmaster HPHE2K80HD045VUN 1**'s 1,387 kWh/yr draw equals roughly $252 annually or $2,520 across a 10-year horizon (ranging from $203/yr in Washington hydro tiers up to $654/yr in Hawaii).

When is U.S. Craftmaster HPHE2K80HD045VUN 1** a poor fit for a residential replacement?

Avoid placing U.S. Craftmaster HPHE2K80HD045VUN 1** directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.

What First Hour Rating or flow capacity does U.S. Craftmaster HPHE2K80HD045VUN 1** deliver?

With 86 gal FHR (+14 gal vs. 72 gal median), U.S. Craftmaster HPHE2K80HD045VUN 1** fits larger 3–5 person homes cleanly.

How do you verify manufacturing age and recall status on U.S. Craftmaster HPHE2K80HD045VUN 1**?

Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for U.S. Craftmaster; verify exact manufacturing week for U.S. Craftmaster HPHE2K80HD045VUN 1** using the Serial Number Lookup tool.

Does U.S. Craftmaster HPHE2K80HD045VUN 1** qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for U.S. Craftmaster HPHE2K80HD045VUN 1**. Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HP1080H45DV 1** (3.45 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks