A. O. Smith HPS10-50H45DV 2** Water Heater Specifications (3.8 UEF)
In the 706-unit Hybrid/Electric Heat Pump class, A. O. Smith HPS10-50H45DV 2** (Electric) achieves a certified 3.8 UEF rating across its 46-gallon nominal tank, 65 gal First Hour Rating (rank #268 of 706, PD 2408844) and verifies as Pass: +1.50 / +65.2% for 2029 DOE floors. Rated annual electricity draw of 831 kWh/yr equates to roughly $151/yr ($1,509 over 10 years) at 18.16 cents/kWh. Closest certified alternative is American HPS10250H045DV 2** (3.8 UEF).
- Uniform Energy Factor
- 3.8 UEF
- Cohort UEF Rank
- #268 of 706 (top 41.9%)
- First Hour Rating
- 65 gal
- Storage Volume
- 46 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.50 / +65.2%

A. O. Smith HPS10-50H45DV 2** records 3.8 UEF efficiency, putting it #268 of 706 among 706 Hybrid/Electric Heat Pump peers.
10 CFR 430.32(d)(2) compliance: A. O. Smith HPS10-50H45DV 2** exceeds 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.50 UEF (+65.2%). At EIA August 2026 national rates (18.16 cents/kWh), 831 kWh/yr for A. O. Smith HPS10-50H45DV 2** runs ~$151/yr vs. ~$623/yr for a 0.92 UEF electric tank.
State electric sensitivity for A. O. Smith HPS10-50H45DV 2**: 10-year operating spend spans $1,216 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $3,921 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Competing options beside A. O. Smith HPS10-50H45DV 2** (3.8 UEF) are American HPS10250H045DV 2** (3.8 UEF, at parity) and Lochinvar HPSA050KD 2** (3.8 UEF, at parity).
Which Specs Set A. O. Smith HPS10-50H45DV 2** Apart From Cohort Averages?
Ranked #268 of 706 (top 41.9%) inside the 706-model Hybrid/Electric Heat Pump cohort, A. O. Smith HPS10-50H45DV 2** is evaluated row by row below against category medians.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | A. O. Smith | 144 certified listings | ENERGY STAR PD 2408844 |
| Model Number | HPS10-50H45DV 2** | Draw pattern: Medium-Usage | HPS10-50H45DV 2** |
| Uniform Energy Factor (UEF) | 3.8 | +0.10 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 65 gal | -7 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 831 kWh/yr | -241 kWh/yr vs. 1,072 kWh/yr median | Est. $151/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 452% | +23.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 63" H x 15" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (15" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 22 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2025-12-12 | Certified 2025-12-12 | Markets: United States |
How Do Regional kWh Prices Impact HPS10-50H45DV 2** Over 10 Years?
Using EIA Table 5.6.A benchmarks, A. O. Smith HPS10-50H45DV 2**'s 831 kWh/yr draw translates to roughly $151/yr on typical US residential bills.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $151/yr | $1,509 | $4,723 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $392/yr | $3,921 | $12,272 |
| California | 29.75 ¢/kWh ($0.2975) | $247/yr | $2,472 | $7,738 |
| Texas | 15.91 ¢/kWh ($0.1591) | $132/yr | $1,322 | $4,138 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $122/yr | $1,216 | $3,805 |
What Should A. O. Smith Owners Check in CPSC Recall Logs?
The 2026-11-23 CPSC SaferProducts snapshot includes 4 filings tied to A. O. Smith; verify whether your HPS10-50H45DV 2** production run falls inside affected ranges. See Serial Number Lookup.
- Recall #19030 (2018-11-08): A. O. Smith Recalls 30-Gallon Gas Water Heaters Due to Fire Hazard; Sold Exclusively at Lowe's (CPSC Notice)
- Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
- Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
- Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)
How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?
Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| American HPS10250H045DV 2** | Hybrid/Electric Heat Pump | 46 gal | 65 gal | 3.8 (at parity) | 831 |
| Lochinvar HPSA050KD 2** | Hybrid/Electric Heat Pump | 46 gal | 65 gal | 3.8 (at parity) | 831 |
| RELIANCE WATER HEATERS 10-50-DHPTS 2** | Hybrid/Electric Heat Pump | 46 gal | 65 gal | 3.8 (at parity) | 831 |
| State HPSX-50-DHPT 2** | Hybrid/Electric Heat Pump | 46 gal | 65 gal | 3.8 (at parity) | 831 |
| Midea CAN3-RSJ-15/190RDVN3-L4 | Hybrid/Electric Heat Pump | 46 gal | 71 gal | 3.75 (-0.05) | 861 |
What Are the Limitations of A. O. Smith HPS10-50H45DV 2** and Who Should Not Install It?
Before ordering A. O. Smith HPS10-50H45DV 2** (Hybrid/Electric Heat Pump, 3.8 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.
Key Limitations & Exclusions
- A. O. Smith HPS10-50H45DV 2** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting A. O. Smith HPS10-50H45DV 2** directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Frequently Asked Technical Questions: A. O. Smith HPS10-50H45DV 2**
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Does A. O. Smith HPS10-50H45DV 2** pass the May 6, 2029 federal DOE efficiency rule?
A. O. Smith HPS10-50H45DV 2** carries a verified 3.8 UEF rating (Pass: +1.50 / +65.2%), ranking #268 of 706 (top 41.9%) across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.
What doorway width and ceiling height does A. O. Smith HPS10-50H45DV 2** need?
A. O. Smith HPS10-50H45DV 2** stands 63 in. high with a 15 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (15" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.
What gas pipe size or electrical breaker does A. O. Smith HPS10-50H45DV 2** require?
A. O. Smith HPS10-50H45DV 2** uses a 240V branch circuit at 22A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.
How much electricity or energy does A. O. Smith HPS10-50H45DV 2** cost per year to run?
Rated at 831 kWh/yr, A. O. Smith HPS10-50H45DV 2** costs about $151/yr ($1,510 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $122/yr in Washington hydro tiers up to $392/yr in Hawaii).
Who should NOT install A. O. Smith HPS10-50H45DV 2**, and what are its limits?
A. O. Smith HPS10-50H45DV 2** (3.8 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.
How many bathrooms or people can A. O. Smith HPS10-50H45DV 2** serve at peak demand?
A. O. Smith HPS10-50H45DV 2** achieves a 65 gal First Hour Rating (-7 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.
Are there CPSC safety recalls or serial checks for A. O. Smith HPS10-50H45DV 2**?
CPSC SaferProducts records show 4 brand-level recall notices mentioning A. O. Smith as of 2026-11-23, including #19030 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
What 2026 rebates apply to A. O. Smith HPS10-50H45DV 2**, and what peer compares closest?
Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is American HPS10250H045DV 2** (3.8 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)