Midea CAN3-RSJ-15/190RDVN3-L4 Water Heater Specifications (3.75 UEF)
The Midea CAN3-RSJ-15/190RDVN3-L4 (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.75 UEF rating across its 46-gallon nominal tank, 71 gal First Hour Rating, ranking #297 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 4654275). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +1.45 / +63.0%. Rated annual electricity draw of 861 kWh/yr equates to roughly $156/yr ($1,564 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Rinnai REHP50CW (3.75 UEF).
- Uniform Energy Factor
- 3.75 UEF
- Cohort UEF Rank
- #297 of 706
- First Hour Rating
- 71 gal
- Storage Volume
- 46 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.45 / +63.0%

Midea CAN3-RSJ-15/190RDVN3-L4 (3.75 UEF) ranks #297 of 706 Hybrid/Electric Heat Pump models — 48-way tie; more efficient than 51.3% of Hybrid/Electric Heat Pump models, +0.05 UEF above the 3.70 UEF median.
Federal 2029 margin for Midea CAN3-RSJ-15/190RDVN3-L4: +1.45 UEF (+63.0%) vs. 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 861 kWh/yr for Midea CAN3-RSJ-15/190RDVN3-L4 runs ~$156/yr vs. ~$637/yr for a 0.92 UEF electric tank. Acoustic output is 49 dBA (quieter than 12.8% of Hybrid/Electric Heat Pump models).
State electric sensitivity for Midea CAN3-RSJ-15/190RDVN3-L4: 10-year operating spend spans $1,260 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,062 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Peer comparison: Midea CAN3-RSJ-15/190RDVN3-L4 (3.75 UEF) compares closely with Rinnai REHP50CW (3.75 UEF, at parity) and A. O. Smith HPS10-50H45DV 2** (3.8 UEF, delta +0.05).
What Physical and Thermal Ratings Define Midea CAN3-RSJ-15/190RDVN3-L4?
Positioning at #297 of 706 out of 706 Hybrid/Electric Heat Pump peers, Midea CAN3-RSJ-15/190RDVN3-L4 pairs measured UEF performance with specific clearance and wiring rules.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Midea | 49 certified listings | ENERGY STAR PD 4654275 |
| Model Number | CAN3-RSJ-15/190RDVN3-L4 | Draw pattern: Medium-Usage | CAN3-RSJ-15/190RDVN3-L4 |
| Uniform Energy Factor (UEF) | 3.75 | +0.05 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 71 gal | -1 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 861 kWh/yr | -211 kWh/yr vs. 1,072 kWh/yr median | Est. $156/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 420% | -9.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 46.6" H x 18.3" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 24 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Sound Pressure Level | 49 dBA | quieter than 12.8% of Hybrid/Electric Heat Pump models · At 49 dBA median | Indoor placement check |
| Certification Date | 2026-07-23 | Certified 2026-07-23 | Markets: United States, Canada |
Why Do State Utility Rates Shift CAN3-RSJ-15/190RDVN3-L4 Running Costs?
Consuming 861 kWh annually puts Midea CAN3-RSJ-15/190RDVN3-L4 near $156/yr at US baseline tariffs, with multi-state EIA comparisons charted below.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $156/yr | $1,564 | $4,811 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $406/yr | $4,062 | $12,498 |
| California | 29.75 ¢/kWh ($0.2975) | $256/yr | $2,561 | $7,881 |
| Texas | 15.91 ¢/kWh ($0.1591) | $137/yr | $1,370 | $4,215 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $126/yr | $1,260 | $3,875 |
Have Any Midea Series Triggered CPSC Recalls?
SaferProducts screening on 2026-11-23 returned zero recall matches for Midea; confirm tank age separately using the rating-plate serial pattern. See Serial Number Lookup.
What Are 5 Direct Alternatives to Midea CAN3-RSJ-15/190RDVN3-L4?
Homeowners cross-shopping Midea CAN3-RSJ-15/190RDVN3-L4 frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Rinnai REHP50CW | Hybrid/Electric Heat Pump | 46 gal | 71 gal | 3.75 (at parity) | 861 |
| A. O. Smith HPS10-50H45DV 2** | Hybrid/Electric Heat Pump | 46 gal | 65 gal | 3.8 (+0.05) | 831 |
| American HPS10250H045DV 2** | Hybrid/Electric Heat Pump | 46 gal | 65 gal | 3.8 (+0.05) | 831 |
| Lochinvar HPSA050KD 2** | Hybrid/Electric Heat Pump | 46 gal | 65 gal | 3.8 (+0.05) | 831 |
| Rinnai REHP50W | Hybrid/Electric Heat Pump | 46 gal | 71 gal | 3.75 (at parity) | 861 |
Which Home Setups Are NOT a Fit for Midea CAN3-RSJ-15/190RDVN3-L4?
Comparing Midea CAN3-RSJ-15/190RDVN3-L4 against Rinnai REHP50CW requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.
Key Limitations & Exclusions
- Midea CAN3-RSJ-15/190RDVN3-L4 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Midea CAN3-RSJ-15/190RDVN3-L4 directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Sizing, Efficiency & Recall Answers for Midea CAN3-RSJ-15/190RDVN3-L4
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
How does Midea CAN3-RSJ-15/190RDVN3-L4 score under 10 CFR 430.32 May 2029 water heater minimums?
Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; Midea CAN3-RSJ-15/190RDVN3-L4 logs 3.75 UEF (Pass: +1.45 / +63.0%) within the 706-unit Hybrid/Electric Heat Pump group.
What physical clearance dimensions apply when installing Midea CAN3-RSJ-15/190RDVN3-L4?
With a 46.6 in. height and 18.3 in. diameter, Midea CAN3-RSJ-15/190RDVN3-L4 fits spaces matching: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.3" d), plus 6–12 in. above for plumbing shutoffs.
What 240V circuit or IFGC fuel line capacity fits Midea CAN3-RSJ-15/190RDVN3-L4?
Powered via 240V at 24A max, Midea CAN3-RSJ-15/190RDVN3-L4 requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.
How do state electricity prices change annual costs for Midea CAN3-RSJ-15/190RDVN3-L4?
Annual electric spend for Midea CAN3-RSJ-15/190RDVN3-L4 (861 kWh/yr) averages $156/yr nationwide (ranging from $126/yr in Washington hydro tiers up to $406/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.
What homeowner setups should avoid choosing Midea CAN3-RSJ-15/190RDVN3-L4?
Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on Midea CAN3-RSJ-15/190RDVN3-L4.
Is Midea CAN3-RSJ-15/190RDVN3-L4 sized adequately for a 2-to-4-person household?
ENERGY STAR certifies Midea CAN3-RSJ-15/190RDVN3-L4 at 71 gal First Hour Rating (-1 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.
Does Midea have active CPSC SaferProducts notices affecting CAN3-RSJ-15/190RDVN3-L4?
Zero CPSC recall alerts matched Midea (2026-11-23 check). Keep your Midea CAN3-RSJ-15/190RDVN3-L4 serial code handy to track standard 6-to-12-year OEM warranty coverage.
Which competing water heater matches Midea CAN3-RSJ-15/190RDVN3-L4 (3.75 UEF) most closely?
State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for Midea CAN3-RSJ-15/190RDVN3-L4. Closest peer in Hybrid/Electric Heat Pump is Rinnai REHP50CW (3.75 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)