Skip to main content
ENERGY STAR water heater model · PD 2408839

Lochinvar HPSA050KD 2** Water Heater Specifications (3.8 UEF)

In the 706-unit Hybrid/Electric Heat Pump class, Lochinvar HPSA050KD 2** (Electric) achieves a certified 3.8 UEF rating across its 46-gallon nominal tank, 65 gal First Hour Rating (rank #268 of 706, PD 2408839) and verifies as Pass: +1.50 / +65.2% for 2029 DOE floors. Rated annual electricity draw of 831 kWh/yr equates to roughly $151/yr ($1,509 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPS10-50H45DV 2** (3.8 UEF).

Uniform Energy Factor
3.8 UEF
Cohort UEF Rank
#268 of 706 (top 41.9%)
First Hour Rating
65 gal
Storage Volume
46 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.50 / +65.2%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Lochinvar HPSA050KD 2** at 3.8 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30Lochinvar HPSA050KD 2**: 3.80
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Lochinvar HPSA050KD 2** relative to the cohort median.
Efficiency comparison & rule summary

Lochinvar HPSA050KD 2** records 3.8 UEF efficiency, putting it #268 of 706 among 706 Hybrid/Electric Heat Pump peers.

10 CFR 430.32(d)(2) compliance: Lochinvar HPSA050KD 2** exceeds 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.50 UEF (+65.2%). At EIA August 2026 national rates (18.16 cents/kWh), 831 kWh/yr for Lochinvar HPSA050KD 2** runs ~$151/yr vs. ~$623/yr for a 0.92 UEF electric tank.

State electric sensitivity for Lochinvar HPSA050KD 2**: 10-year operating spend spans $1,216 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $3,921 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Competing options beside Lochinvar HPSA050KD 2** (3.8 UEF) are A. O. Smith HPS10-50H45DV 2** (3.8 UEF, at parity) and American HPS10250H045DV 2** (3.8 UEF, at parity).

How Do Lochinvar HPSA050KD 2** Specs Compare to Hybrid/Electric Heat Pump Medians?

Lochinvar HPSA050KD 2** places #268 of 706 (top 41.9%) across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandLochinvar65 certified listingsENERGY STAR PD 2408839
Model NumberHPSA050KD 2**Draw pattern: Medium-UsageHPSA050KD 2**
Uniform Energy Factor (UEF)3.8+0.10 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)65 gal-7 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use831 kWh/yr-241 kWh/yr vs. 1,072 kWh/yr medianEst. $151/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency452%+23.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)63" H x 15" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (15" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 22 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2025-12-12Certified 2025-12-12Markets: United States

What Does HPSA050KD 2** Cost to Operate Across State Electricity Rates?

At 831 kWh/yr, Lochinvar HPSA050KD 2** runs roughly $151/yr on the EIA national average tier under August 2026 Table 5.6.A rates.

Estimated Annual Electricity Cost by State Rate (831 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$151.00/yrHawaii$392.00/yrCalifornia$247.00/yrTexas$132.00/yrWashington$122.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $151/yr $1,509 $4,723
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $392/yr $3,921 $12,272
California 29.75 ¢/kWh ($0.2975) $247/yr $2,472 $7,738
Texas 15.91 ¢/kWh ($0.1591) $132/yr $1,322 $4,138
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $122/yr $1,216 $3,805
Estimated electricity spend (831 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are There Active CPSC Safety Recalls for Lochinvar Water Heaters?

Our 2026-11-23 CPSC SaferProducts query surfaced 1 brand-level recall notice associated with Lochinvar; match your serial plate before repair. See Serial Number Lookup.

1 Brand Recall Notice Found in CPSC Feed — Verify Serial & Model Range
  • Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)

Which Certified Water Heaters Match HPSA050KD 2** Most Closely?

These 5 competing Hybrid/Electric Heat Pump units sit nearest to Lochinvar HPSA050KD 2** by storage capacity and 3.8 UEF rating.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith HPS10-50H45DV 2** Hybrid/Electric Heat Pump 46 gal 65 gal 3.8 (at parity) 831
American HPS10250H045DV 2** Hybrid/Electric Heat Pump 46 gal 65 gal 3.8 (at parity) 831
RELIANCE WATER HEATERS 10-50-DHPTS 2** Hybrid/Electric Heat Pump 46 gal 65 gal 3.8 (at parity) 831
State HPSX-50-DHPT 2** Hybrid/Electric Heat Pump 46 gal 65 gal 3.8 (at parity) 831
A. O. Smith HPSN10-50H45DV 2** Hybrid/Electric Heat Pump 46 gal 65 gal 3.8 (at parity) 831

When Should Homeowners Skip Lochinvar HPSA050KD 2** (Hybrid/Electric Heat Pump)?

Check Lochinvar HPSA050KD 2**'s mechanical constraints—including utility space, Electric capacity, and Pass: +1.50 / +65.2% status—against typical residential installations.

Key Limitations & Exclusions

  • Lochinvar HPSA050KD 2** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Lochinvar HPSA050KD 2** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Lochinvar HPSA050KD 2** Strong Fit — 3.8 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare A. O. Smith HPS10-50H45DV 2** footprint.

What Are the Key Questions About Lochinvar HPSA050KD 2**?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Will Lochinvar HPSA050KD 2** stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 3.8 UEF, Lochinvar HPSA050KD 2** shows Pass: +1.50 / +65.2% relative to May 6, 2029 federal DOE limits while placing #268 of 706 (top 41.9%) among 706 Hybrid/Electric Heat Pump peers like A. O. Smith HPS10-50H45DV 2**.

Will Lochinvar HPSA050KD 2** fit through a standard utility door and 72-inch basement ceiling?

Measuring 63 in. tall by 15 in. diameter, Lochinvar HPSA050KD 2** notes: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (15" d). Reserve space above the jacket for T&P piping and anode removal.

Do existing utility hookups support Lochinvar HPSA050KD 2** during replacement?

Electrical specs for Lochinvar HPSA050KD 2** call for 240V at 22A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.

What is the estimated 10-year operating spend for Lochinvar HPSA050KD 2**?

At 18.16 cents/kWh national residential pricing, Lochinvar HPSA050KD 2**'s 831 kWh/yr draw equals roughly $151 annually or $1,510 across a 10-year horizon (ranging from $122/yr in Washington hydro tiers up to $392/yr in Hawaii).

When is Lochinvar HPSA050KD 2** a poor fit for a residential replacement?

Avoid placing Lochinvar HPSA050KD 2** directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.

What First Hour Rating or flow capacity does Lochinvar HPSA050KD 2** deliver?

With 65 gal FHR (-7 gal vs. 72 gal median), Lochinvar HPSA050KD 2** fits larger 3–5 person homes cleanly.

How do you verify manufacturing age and recall status on Lochinvar HPSA050KD 2**?

CPSC SaferProducts records show 1 brand-level recall notice mentioning Lochinvar as of 2026-11-23, including #05274 (2005-09-16). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

Does Lochinvar HPSA050KD 2** qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Lochinvar HPSA050KD 2**. Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPS10-50H45DV 2** (3.8 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks