Skip to main content
ENERGY STAR water heater model · PD 2408838

RELIANCE WATER HEATERS 10-50-DHPTS 2** Water Heater Specifications (3.8 UEF)

With PD 2408838 certification, RELIANCE WATER HEATERS 10-50-DHPTS 2** (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.8 UEF rating across its 46-gallon nominal tank, 65 gal First Hour Rating, standing #268 of 706 across 706 peers with Pass: +1.50 / +65.2% for May 6, 2029. Rated annual electricity draw of 831 kWh/yr equates to roughly $151/yr ($1,509 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPS10-50H45DV 2** (3.8 UEF).

Uniform Energy Factor
3.8 UEF
Cohort UEF Rank
#268 of 706 (top 41.9%)
First Hour Rating
65 gal
Storage Volume
46 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.50 / +65.2%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking RELIANCE WATER HEATERS 10-50-DHPTS 2** at 3.8 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30RELIANCE WATER HEATERS 10-50-DHPTS 2**: 3.80
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows RELIANCE WATER HEATERS 10-50-DHPTS 2** relative to the cohort median.
Efficiency comparison & rule summary

ENERGY STAR certification places RELIANCE WATER HEATERS 10-50-DHPTS 2** at 3.8 UEF (#268 of 706; +0.10 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.

May 6, 2029 readiness: RELIANCE WATER HEATERS 10-50-DHPTS 2** stands +1.50 UEF (+65.2%) relative to 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 831 kWh/yr for RELIANCE WATER HEATERS 10-50-DHPTS 2** runs ~$151/yr vs. ~$623/yr for a 0.92 UEF electric tank.

State electric sensitivity for RELIANCE WATER HEATERS 10-50-DHPTS 2**: 10-year operating spend spans $1,216 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $3,921 in Hawaii (Highest EIA State) (47.18 cents/kWh).

In the Hybrid/Electric Heat Pump tier, A. O. Smith HPS10-50H45DV 2** (3.8 UEF, at parity) and American HPS10250H045DV 2** (3.8 UEF, at parity) bracket RELIANCE WATER HEATERS 10-50-DHPTS 2**.

How Do RELIANCE WATER HEATERS 10-50-DHPTS 2** Specs Compare to Hybrid/Electric Heat Pump Medians?

RELIANCE WATER HEATERS 10-50-DHPTS 2** places #268 of 706 (top 41.9%) across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRELIANCE WATER HEATERS71 certified listingsENERGY STAR PD 2408838
Model Number10-50-DHPTS 2**Draw pattern: Medium-Usage10-50-DHPTS 2**
Uniform Energy Factor (UEF)3.8+0.10 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)65 gal-7 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use831 kWh/yr-241 kWh/yr vs. 1,072 kWh/yr medianEst. $151/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency452%+23.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)63" H x 15" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (15" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 22 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2025-12-12Certified 2025-12-12Markets: United States

What Does 10-50-DHPTS 2** Cost to Operate Across State Electricity Rates?

At 831 kWh/yr, RELIANCE WATER HEATERS 10-50-DHPTS 2** runs roughly $151/yr on the EIA national average tier under August 2026 Table 5.6.A rates.

Estimated Annual Electricity Cost by State Rate (831 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$151.00/yrHawaii$392.00/yrCalifornia$247.00/yrTexas$132.00/yrWashington$122.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $151/yr $1,509 $4,723
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $392/yr $3,921 $12,272
California 29.75 ¢/kWh ($0.2975) $247/yr $2,472 $7,738
Texas 15.91 ¢/kWh ($0.1591) $132/yr $1,322 $4,138
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $122/yr $1,216 $3,805
Estimated electricity spend (831 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are There Active CPSC Safety Recalls for RELIANCE WATER HEATERS Water Heaters?

Our 2026-11-23 CPSC SaferProducts query surfaced 3 brand-level recall notices associated with RELIANCE WATER HEATERS; match your serial plate before repair. See Serial Number Lookup.

3 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
  • Recall #04128 (2004-04-28): CPSC, White-Rodgers Announce Recall of LP and Convertible Gas Water Heater Temperature Controls (CPSC Notice)

Which Certified Water Heaters Match 10-50-DHPTS 2** Most Closely?

These 5 competing Hybrid/Electric Heat Pump units sit nearest to RELIANCE WATER HEATERS 10-50-DHPTS 2** by storage capacity and 3.8 UEF rating.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith HPS10-50H45DV 2** Hybrid/Electric Heat Pump 46 gal 65 gal 3.8 (at parity) 831
American HPS10250H045DV 2** Hybrid/Electric Heat Pump 46 gal 65 gal 3.8 (at parity) 831
Lochinvar HPSA050KD 2** Hybrid/Electric Heat Pump 46 gal 65 gal 3.8 (at parity) 831
State HPSX-50-DHPT 2** Hybrid/Electric Heat Pump 46 gal 65 gal 3.8 (at parity) 831
A. O. Smith HPSN10-50H45DV 2** Hybrid/Electric Heat Pump 46 gal 65 gal 3.8 (at parity) 831

Who Is RELIANCE WATER HEATERS 10-50-DHPTS 2** Best For — and When Should You Pick A. O. Smith HPS10-50H45DV 2**?

Evaluate whether RELIANCE WATER HEATERS 10-50-DHPTS 2**'s Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.

Key Limitations & Exclusions

  • RELIANCE WATER HEATERS 10-50-DHPTS 2** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting RELIANCE WATER HEATERS 10-50-DHPTS 2** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing RELIANCE WATER HEATERS 10-50-DHPTS 2** Strong Fit — 3.8 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare A. O. Smith HPS10-50H45DV 2** footprint.

What Are the Key Questions About RELIANCE WATER HEATERS 10-50-DHPTS 2**?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does RELIANCE WATER HEATERS 10-50-DHPTS 2** (3.8 UEF) compare to 2029 federal DOE floors?

Evaluated against May 6, 2029 10 CFR 430.32 thresholds, RELIANCE WATER HEATERS 10-50-DHPTS 2** records 3.8 UEF (Pass: +1.50 / +65.2%), placing #268 of 706 (top 41.9%) out of 706 certified Hybrid/Electric Heat Pump configurations.

Does RELIANCE WATER HEATERS 10-50-DHPTS 2** fit inside a tight hallway closet or low-headroom utility room?

RELIANCE WATER HEATERS 10-50-DHPTS 2** requires room for its 63 in. vertical shell and 15 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (15" d)), plus service access for annual sediment draining.

What power supply or fuel line specs govern RELIANCE WATER HEATERS 10-50-DHPTS 2**?

For RELIANCE WATER HEATERS 10-50-DHPTS 2**, plan a 240V circuit at 22A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.

What annual utility bill should homeowners budget for RELIANCE WATER HEATERS 10-50-DHPTS 2**?

Using 831 kWh/yr, RELIANCE WATER HEATERS 10-50-DHPTS 2** generates an estimated $151/yr electric bill at 18.16 cents/kWh (ranging from $122/yr in Washington hydro tiers up to $392/yr in Hawaii)—use the custom rate slider above for your utility tariff.

What are the main drawbacks of RELIANCE WATER HEATERS 10-50-DHPTS 2** (3.8 UEF)?

RELIANCE WATER HEATERS 10-50-DHPTS 2** requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or A. O. Smith HPS10-50H45DV 2**.

What hot-water delivery rating governs RELIANCE WATER HEATERS 10-50-DHPTS 2**?

Rated for 65 gal FHR (-7 gal vs. 72 gal median), RELIANCE WATER HEATERS 10-50-DHPTS 2** prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.

Where do homeowners screen RELIANCE WATER HEATERS 10-50-DHPTS 2** for recalls and tank age?

CPSC SaferProducts records show 3 brand-level recall notices mentioning RELIANCE WATER HEATERS as of 2026-11-23, including #19029 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

What alternative models sit closest to RELIANCE WATER HEATERS 10-50-DHPTS 2** in the Hybrid/Electric Heat Pump class?

Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPS10-50H45DV 2** (3.8 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks