Skip to main content
ENERGY STAR water heater model · PD 4015935

A. O. Smith HPSN10-50H45DV 2** Water Heater Specifications (3.8 UEF)

The A. O. Smith HPSN10-50H45DV 2** (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.8 UEF rating across its 46-gallon nominal tank, 65 gal First Hour Rating, ranking #268 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 4015935). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +1.50 / +65.2%. Rated annual electricity draw of 831 kWh/yr equates to roughly $151/yr ($1,509 over 10 years) at 18.16 cents/kWh. Closest certified alternative is American HPS10250H045DV 2** (3.8 UEF).

Uniform Energy Factor
3.8 UEF
Cohort UEF Rank
#268 of 706 (top 41.9%)
First Hour Rating
65 gal
Storage Volume
46 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.50 / +65.2%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking A. O. Smith HPSN10-50H45DV 2** at 3.8 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30A. O. Smith HPSN10-50H45DV 2**: 3.80
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows A. O. Smith HPSN10-50H45DV 2** relative to the cohort median.
Efficiency comparison & rule summary

A. O. Smith HPSN10-50H45DV 2** (3.8 UEF) ranks #268 of 706 Hybrid/Electric Heat Pump models — 29-way tie; top 41.9%, more efficient than 58.1% of Hybrid/Electric Heat Pump models, +0.10 UEF above the 3.70 UEF median.

Federal 2029 margin for A. O. Smith HPSN10-50H45DV 2**: +1.50 UEF (+65.2%) vs. 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 831 kWh/yr for A. O. Smith HPSN10-50H45DV 2** runs ~$151/yr vs. ~$623/yr for a 0.92 UEF electric tank.

State electric sensitivity for A. O. Smith HPSN10-50H45DV 2**: 10-year operating spend spans $1,216 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $3,921 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Peer comparison: A. O. Smith HPSN10-50H45DV 2** (3.8 UEF) compares closely with American HPS10250H045DV 2** (3.8 UEF, at parity) and Lochinvar HPSA050KD 2** (3.8 UEF, at parity).

Where Does A. O. Smith HPSN10-50H45DV 2** Rank Against Peer Hybrid/Electric Heat Pump Units?

Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, A. O. Smith HPSN10-50H45DV 2** holds #268 of 706 (top 41.9%); inspect footprint, circuit load, and efficiency deltas here.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandA. O. Smith144 certified listingsENERGY STAR PD 4015935
Model NumberHPSN10-50H45DV 2**Draw pattern: Medium-UsageHPSN10-50H45DV 2**
Uniform Energy Factor (UEF)3.8+0.10 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)65 gal-7 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use831 kWh/yr-241 kWh/yr vs. 1,072 kWh/yr medianEst. $151/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency452%+23.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)63" H x 15" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (15" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 22 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2025-12-12Certified 2025-12-12Markets: United States

How Much Electricity Does HPSN10-50H45DV 2** Use in Different States?

Estimated at $151/yr nationally (831 kWh/yr), 10-year utility spending for A. O. Smith HPSN10-50H45DV 2** shifts sharply between low-rate hydro and coastal grids.

Estimated Annual Electricity Cost by State Rate (831 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$151.00/yrHawaii$392.00/yrCalifornia$247.00/yrTexas$132.00/yrWashington$122.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $151/yr $1,509 $4,723
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $392/yr $3,921 $12,272
California 29.75 ¢/kWh ($0.2975) $247/yr $2,472 $7,738
Texas 15.91 ¢/kWh ($0.1591) $132/yr $1,322 $4,138
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $122/yr $1,216 $3,805
Estimated electricity spend (831 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Does CPSC Flag Any Safety Notices on A. O. Smith Units?

Checking 2026-11-23 SaferProducts data shows 4 notices mentioning A. O. Smith; always cross-reference affected serial prefixes before ordering components. See Serial Number Lookup.

4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #19030 (2018-11-08): A. O. Smith Recalls 30-Gallon Gas Water Heaters Due to Fire Hazard; Sold Exclusively at Lowe's (CPSC Notice)
  • Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
  • Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)

Which Competing Hybrid/Electric Heat Pump Models Compare Closest to HPSN10-50H45DV 2**?

Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to A. O. Smith HPSN10-50H45DV 2**'s gallon capacity and 3.8 UEF efficiency.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
American HPS10250H045DV 2** Hybrid/Electric Heat Pump 46 gal 65 gal 3.8 (at parity) 831
Lochinvar HPSA050KD 2** Hybrid/Electric Heat Pump 46 gal 65 gal 3.8 (at parity) 831
RELIANCE WATER HEATERS 10-50-DHPTS 2** Hybrid/Electric Heat Pump 46 gal 65 gal 3.8 (at parity) 831
State HPSX-50-DHPT 2** Hybrid/Electric Heat Pump 46 gal 65 gal 3.8 (at parity) 831
Midea CAN3-RSJ-15/190RDVN3-L4 Hybrid/Electric Heat Pump 46 gal 71 gal 3.75 (-0.05) 861

What Installation Caveats Apply Before Buying A. O. Smith HPSN10-50H45DV 2**?

Even high-UEF units like A. O. Smith HPSN10-50H45DV 2** (3.8 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

Key Limitations & Exclusions

  • A. O. Smith HPSN10-50H45DV 2** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting A. O. Smith HPSN10-50H45DV 2** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing A. O. Smith HPSN10-50H45DV 2** Strong Fit — 3.8 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare American HPS10250H045DV 2** footprint.

Common Homeowner Questions for A. O. Smith HPSN10-50H45DV 2**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Is A. O. Smith HPSN10-50H45DV 2** eligible for continued manufacture past May 6, 2029?

At 3.8 UEF, A. O. Smith HPSN10-50H45DV 2** achieves Pass: +1.50 / +65.2% for the 2029 DOE standard and stands #268 of 706 (top 41.9%) against American HPS10250H045DV 2** and Lochinvar HPSA050KD 2**.

How tall and wide is A. O. Smith HPSN10-50H45DV 2**, and what service clearance is needed?

Physical dimensions for A. O. Smith HPSN10-50H45DV 2** are 63 in. height and 15 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (15" d)); verify stair turns and drain pan width before delivery.

Will A. O. Smith HPSN10-50H45DV 2** require upgrading household electrical panels or gas piping?

A. O. Smith HPSN10-50H45DV 2** draws 240V at 22A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.

Is A. O. Smith HPSN10-50H45DV 2** economical to operate at 18.16 cents/kWh US electric rates?

Expect roughly $151/yr ($1,510 over 10 years) to power A. O. Smith HPSN10-50H45DV 2** at 831 kWh/yr under the 18.16 cents/kWh US average (ranging from $122/yr in Washington hydro tiers up to $392/yr in Hawaii).

Which installation bottlenecks limit A. O. Smith HPSN10-50H45DV 2**?

If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, A. O. Smith HPSN10-50H45DV 2** drops into resistance mode more often.

How does A. O. Smith HPSN10-50H45DV 2** handle simultaneous showers and laundry?

Delivering 65 gal in the first hour (-7 gal vs. 72 gal median), A. O. Smith HPSN10-50H45DV 2** combines 46 gal tank storage with rapid burner/element recovery.

How long is the warranty on A. O. Smith HPSN10-50H45DV 2** and how do you decode its serial?

CPSC SaferProducts records show 4 brand-level recall notices mentioning A. O. Smith as of 2026-11-23, including #19030 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

How do 2026 post-OBBBA rebates affect buying A. O. Smith HPSN10-50H45DV 2**?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is American HPS10250H045DV 2** (3.8 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks