ENERGY STAR water heater model · PD 2408851

A. O. Smith HPTS-50 2** Water Heater Specifications (3.8 UEF)

Certified at 3.8 UEF across its 46-gallon nominal tank, 65 gal First Hour Rating, A. O. Smith HPTS-50 2** (Hybrid/Electric Heat Pump, Electric) places #268 of 706 out of 706 ENERGY STAR models (PD 2408851). Its May 6, 2029 10 CFR 430.32 status reads Pass: +1.50 / +65.2%. Rated annual electricity draw of 831 kWh/yr equates to roughly $151/yr ($1,509 over 10 years) at 18.16 cents/kWh. Closest certified alternative is American HPS10250H045DV 2** (3.8 UEF).

Uniform Energy Factor
3.8 UEF
Cohort UEF Rank
#268 of 706 (top 41.9%)
First Hour Rating
65 gal
Storage Volume
46 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.50 / +65.2%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking A. O. Smith HPTS-50 2** at 3.8 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30A. O. Smith HPTS-50 2**: 3.80
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows A. O. Smith HPTS-50 2** relative to the cohort median.
Efficiency comparison & rule summary

Tested at 3.8 UEF, A. O. Smith HPTS-50 2** places #268 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (+0.10 UEF vs. 3.70 UEF median).

A. O. Smith HPTS-50 2** clears 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.50 UEF (+65.2% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 831 kWh/yr for A. O. Smith HPTS-50 2** runs ~$151/yr vs. ~$623/yr for a 0.92 UEF electric tank.

State electric sensitivity for A. O. Smith HPTS-50 2**: 10-year operating spend spans $1,216 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $3,921 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Closest alternatives to A. O. Smith HPTS-50 2** include American HPS10250H045DV 2** (3.8 UEF, at parity) alongside Lochinvar HPSA050KD 2** (3.8 UEF, at parity).

Which Specs Set A. O. Smith HPTS-50 2** Apart From Cohort Averages?

Ranked #268 of 706 (top 41.9%) inside the 706-model Hybrid/Electric Heat Pump cohort, A. O. Smith HPTS-50 2** is evaluated row by row below against category medians.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandA. O. Smith144 certified listingsENERGY STAR PD 2408851
Model NumberHPTS-50 2**Draw pattern: Medium-UsageHPTS-50 2**
Uniform Energy Factor (UEF)3.8+0.10 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)65 gal-7 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use831 kWh/yr-241 kWh/yr vs. 1,072 kWh/yr medianEst. $151/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency452%+23.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)63" H x 15" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (15" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 22 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2025-12-12Certified 2025-12-12Markets: United States, Canada

How Do Regional kWh Prices Impact HPTS-50 2** Over 10 Years?

Using EIA Table 5.6.A benchmarks, A. O. Smith HPTS-50 2**'s 831 kWh/yr draw translates to roughly $151/yr on typical US residential bills.

Estimated Annual Electricity Cost by State Rate (831 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$151.00/yrHawaii$392.00/yrCalifornia$247.00/yrTexas$132.00/yrWashington$122.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $151/yr $1,509 $4,723
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $392/yr $3,921 $12,272
California 29.75 ¢/kWh ($0.2975) $247/yr $2,472 $7,738
Texas 15.91 ¢/kWh ($0.1591) $132/yr $1,322 $4,138
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $122/yr $1,216 $3,805
Estimated electricity spend (831 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

What Should A. O. Smith Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC SaferProducts snapshot includes 4 filings tied to A. O. Smith; verify whether your HPTS-50 2** production run falls inside affected ranges. See Serial Number Lookup.

4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #19030 (2018-11-08): A. O. Smith Recalls 30-Gallon Gas Water Heaters Due to Fire Hazard; Sold Exclusively at Lowe's (CPSC Notice)
  • Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
  • Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)

How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?

Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
American HPS10250H045DV 2** Hybrid/Electric Heat Pump 46 gal 65 gal 3.8 (at parity) 831
Lochinvar HPSA050KD 2** Hybrid/Electric Heat Pump 46 gal 65 gal 3.8 (at parity) 831
RELIANCE WATER HEATERS 10-50-DHPTS 2** Hybrid/Electric Heat Pump 46 gal 65 gal 3.8 (at parity) 831
State HPSX-50-DHPT 2** Hybrid/Electric Heat Pump 46 gal 65 gal 3.8 (at parity) 831
Midea CAN3-RSJ-15/190RDVN3-L4 Hybrid/Electric Heat Pump 46 gal 71 gal 3.75 (-0.05) 861

When Should Homeowners Skip A. O. Smith HPTS-50 2** (Hybrid/Electric Heat Pump)?

Check A. O. Smith HPTS-50 2**'s mechanical constraints—including utility space, Electric capacity, and Pass: +1.50 / +65.2% status—against typical residential installations.

Key Limitations & Exclusions

  • A. O. Smith HPTS-50 2** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting A. O. Smith HPTS-50 2** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing A. O. Smith HPTS-50 2** Strong Fit — 3.8 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare American HPS10250H045DV 2** footprint.

Frequently Asked Technical Questions: A. O. Smith HPTS-50 2**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Will A. O. Smith HPTS-50 2** stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 3.8 UEF, A. O. Smith HPTS-50 2** shows Pass: +1.50 / +65.2% relative to May 6, 2029 federal DOE limits while placing #268 of 706 (top 41.9%) among 706 Hybrid/Electric Heat Pump peers like American HPS10250H045DV 2**.

Will A. O. Smith HPTS-50 2** fit through a standard utility door and 72-inch basement ceiling?

Measuring 63 in. tall by 15 in. diameter, A. O. Smith HPTS-50 2** notes: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (15" d). Reserve space above the jacket for T&P piping and anode removal.

Do existing utility hookups support A. O. Smith HPTS-50 2** during replacement?

Electrical specs for A. O. Smith HPTS-50 2** call for 240V at 22A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.

What is the estimated 10-year operating spend for A. O. Smith HPTS-50 2**?

At 18.16 cents/kWh national residential pricing, A. O. Smith HPTS-50 2**'s 831 kWh/yr draw equals roughly $151 annually or $1,510 across a 10-year horizon (ranging from $122/yr in Washington hydro tiers up to $392/yr in Hawaii).

When is A. O. Smith HPTS-50 2** a poor fit for a residential replacement?

Avoid placing A. O. Smith HPTS-50 2** directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.

What First Hour Rating or flow capacity does A. O. Smith HPTS-50 2** deliver?

With 65 gal FHR (-7 gal vs. 72 gal median), A. O. Smith HPTS-50 2** fits larger 3–5 person homes cleanly.

How do you verify manufacturing age and recall status on A. O. Smith HPTS-50 2**?

CPSC SaferProducts records show 4 brand-level recall notices mentioning A. O. Smith as of 2026-11-23, including #19030 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

Does A. O. Smith HPTS-50 2** qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for A. O. Smith HPTS-50 2**. Closest peer in Hybrid/Electric Heat Pump is American HPS10250H045DV 2** (3.8 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks