A. O. Smith HPTU-50DR 1** Water Heater Specifications (3.45 UEF)
Certified at 3.45 UEF across its 46-gallon nominal tank, 66 gal First Hour Rating, A. O. Smith HPTU-50DR 1** (Hybrid/Electric Heat Pump, Electric) places #563 of 706 out of 706 ENERGY STAR models (PD 2408896). Its May 6, 2029 10 CFR 430.32 status reads Pass: +1.15 / +50.0%. Rated annual electricity draw of 902 kWh/yr equates to roughly $164/yr ($1,638 over 10 years) at 18.16 cents/kWh. Closest certified alternative is American HPHE10250H045DVCTA-1** (3.45 UEF).
- Uniform Energy Factor
- 3.45 UEF
- Cohort UEF Rank
- #563 of 706
- First Hour Rating
- 66 gal
- Storage Volume
- 46 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.15 / +50.0%

Tested at 3.45 UEF, A. O. Smith HPTU-50DR 1** places #563 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (-0.25 UEF vs. 3.70 UEF median).
A. O. Smith HPTU-50DR 1** clears 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.15 UEF (+50.0% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 902 kWh/yr for A. O. Smith HPTU-50DR 1** runs ~$164/yr vs. ~$614/yr for a 0.92 UEF electric tank.
State electric sensitivity for A. O. Smith HPTU-50DR 1**: 10-year operating spend spans $1,320 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,256 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Closest alternatives to A. O. Smith HPTU-50DR 1** include American HPHE10250H045DVCTA-1** (3.45 UEF, at parity) alongside Lochinvar HPA052KD 1** (3.45 UEF, at parity).
What Physical and Thermal Ratings Define A. O. Smith HPTU-50DR 1**?
Positioning at #563 of 706 out of 706 Hybrid/Electric Heat Pump peers, A. O. Smith HPTU-50DR 1** pairs measured UEF performance with specific clearance and wiring rules.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | A. O. Smith | 144 certified listings | ENERGY STAR PD 2408896 |
| Model Number | HPTU-50DR 1** | Draw pattern: Medium-Usage | HPTU-50DR 1** |
| Uniform Energy Factor (UEF) | 3.45 | -0.25 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 66 gal | -6 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 902 kWh/yr | -170 kWh/yr vs. 1,072 kWh/yr median | Est. $164/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 407% | -22.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 63" H x 15" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (15" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 22 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2023-02-23 | Certified 2023-02-23 | Markets: United States, Canada |
Why Do State Utility Rates Shift HPTU-50DR 1** Running Costs?
Consuming 902 kWh annually puts A. O. Smith HPTU-50DR 1** near $164/yr at US baseline tariffs, with multi-state EIA comparisons charted below.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $164/yr | $1,638 | $4,504 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $426/yr | $4,256 | $11,701 |
| California | 29.75 ¢/kWh ($0.2975) | $268/yr | $2,683 | $7,378 |
| Texas | 15.91 ¢/kWh ($0.1591) | $144/yr | $1,435 | $3,946 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $132/yr | $1,320 | $3,628 |
Have Any A. O. Smith Series Triggered CPSC Recalls?
SaferProducts records retrieved 2026-11-23 list 4 brand notices under A. O. Smith; inspect model coverage dates prior to valve or anode service. See Serial Number Lookup.
- Recall #19030 (2018-11-08): A. O. Smith Recalls 30-Gallon Gas Water Heaters Due to Fire Hazard; Sold Exclusively at Lowe's (CPSC Notice)
- Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
- Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
- Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)
What Are 5 Direct Alternatives to A. O. Smith HPTU-50DR 1**?
Homeowners cross-shopping A. O. Smith HPTU-50DR 1** frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| American HPHE10250H045DVCTA-1** | Hybrid/Electric Heat Pump | 46 gal | 66 gal | 3.45 (at parity) | 902 |
| Lochinvar HPA052KD 1** | Hybrid/Electric Heat Pump | 46 gal | 66 gal | 3.45 (at parity) | 902 |
| RELIANCE WATER HEATERS 10-50-DHPHTCTA 1** | Hybrid/Electric Heat Pump | 46 gal | 66 gal | 3.45 (at parity) | 902 |
| State HPX-50-DHPTCTA 1** | Hybrid/Electric Heat Pump | 46 gal | 66 gal | 3.45 (at parity) | 902 |
| American HPHE10250H045DVDR 1** | Hybrid/Electric Heat Pump | 46 gal | 66 gal | 3.45 (at parity) | 902 |
Which Home Setups Are NOT a Fit for A. O. Smith HPTU-50DR 1**?
Comparing A. O. Smith HPTU-50DR 1** against American HPHE10250H045DVCTA-1** requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.
Key Limitations & Exclusions
- A. O. Smith HPTU-50DR 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting A. O. Smith HPTU-50DR 1** directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Sizing, Efficiency & Recall Answers for A. O. Smith HPTU-50DR 1**
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
How does A. O. Smith HPTU-50DR 1** score under 10 CFR 430.32 May 2029 water heater minimums?
Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; A. O. Smith HPTU-50DR 1** logs 3.45 UEF (Pass: +1.15 / +50.0%) within the 706-unit Hybrid/Electric Heat Pump group.
What physical clearance dimensions apply when installing A. O. Smith HPTU-50DR 1**?
With a 63 in. height and 15 in. diameter, A. O. Smith HPTU-50DR 1** fits spaces matching: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (15" d), plus 6–12 in. above for plumbing shutoffs.
What 240V circuit or IFGC fuel line capacity fits A. O. Smith HPTU-50DR 1**?
Powered via 240V at 22A max, A. O. Smith HPTU-50DR 1** requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.
How do state electricity prices change annual costs for A. O. Smith HPTU-50DR 1**?
Annual electric spend for A. O. Smith HPTU-50DR 1** (902 kWh/yr) averages $164/yr nationwide (ranging from $132/yr in Washington hydro tiers up to $426/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.
What homeowner setups should avoid choosing A. O. Smith HPTU-50DR 1**?
Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on A. O. Smith HPTU-50DR 1**.
Is A. O. Smith HPTU-50DR 1** sized adequately for a 2-to-4-person household?
ENERGY STAR certifies A. O. Smith HPTU-50DR 1** at 66 gal First Hour Rating (-6 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.
Does A. O. Smith have active CPSC SaferProducts notices affecting HPTU-50DR 1**?
CPSC SaferProducts records show 4 brand-level recall notices mentioning A. O. Smith as of 2026-11-23, including #19030 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
Which competing water heater matches A. O. Smith HPTU-50DR 1** (3.45 UEF) most closely?
State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for A. O. Smith HPTU-50DR 1**. Closest peer in Hybrid/Electric Heat Pump is American HPHE10250H045DVCTA-1** (3.45 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)