Skip to main content
ENERGY STAR water heater model · PD 2408905

A. O. Smith HPTU-50N 1** Water Heater Specifications (3.45 UEF)

The A. O. Smith HPTU-50N 1** (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.45 UEF rating across its 46-gallon nominal tank, 66 gal First Hour Rating, ranking #563 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 2408905). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +1.15 / +50.0%. Rated annual electricity draw of 902 kWh/yr equates to roughly $164/yr ($1,638 over 10 years) at 18.16 cents/kWh. Closest certified alternative is American HPHE10250H045DVCTA-1** (3.45 UEF).

Uniform Energy Factor
3.45 UEF
Cohort UEF Rank
#563 of 706
First Hour Rating
66 gal
Storage Volume
46 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.15 / +50.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking A. O. Smith HPTU-50N 1** at 3.45 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30A. O. Smith HPTU-50N 1**: 3.45
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows A. O. Smith HPTU-50N 1** relative to the cohort median.
Efficiency comparison & rule summary

A. O. Smith HPTU-50N 1** (3.45 UEF) ranks #563 of 706 Hybrid/Electric Heat Pump models — 59-way tie; more efficient than 12% of Hybrid/Electric Heat Pump models, -0.25 UEF below the 3.70 UEF median.

Federal 2029 margin for A. O. Smith HPTU-50N 1**: +1.15 UEF (+50.0%) vs. 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 902 kWh/yr for A. O. Smith HPTU-50N 1** runs ~$164/yr vs. ~$614/yr for a 0.92 UEF electric tank.

State electric sensitivity for A. O. Smith HPTU-50N 1**: 10-year operating spend spans $1,320 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,256 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Peer comparison: A. O. Smith HPTU-50N 1** (3.45 UEF) compares closely with American HPHE10250H045DVCTA-1** (3.45 UEF, at parity) and Lochinvar HPA052KD 1** (3.45 UEF, at parity).

Which Specs Set A. O. Smith HPTU-50N 1** Apart From Cohort Averages?

Ranked #563 of 706 inside the 706-model Hybrid/Electric Heat Pump cohort, A. O. Smith HPTU-50N 1** is evaluated row by row below against category medians.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandA. O. Smith144 certified listingsENERGY STAR PD 2408905
Model NumberHPTU-50N 1**Draw pattern: Medium-UsageHPTU-50N 1**
Uniform Energy Factor (UEF)3.45-0.25 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)66 gal-6 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use902 kWh/yr-170 kWh/yr vs. 1,072 kWh/yr medianEst. $164/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency407%-22.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)63" H x 15" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (15" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 22 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2023-02-23Certified 2023-02-23Markets: United States, Canada

How Do Regional kWh Prices Impact HPTU-50N 1** Over 10 Years?

Using EIA Table 5.6.A benchmarks, A. O. Smith HPTU-50N 1**'s 902 kWh/yr draw translates to roughly $164/yr on typical US residential bills.

Estimated Annual Electricity Cost by State Rate (902 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$164.00/yrHawaii$426.00/yrCalifornia$268.00/yrTexas$144.00/yrWashington$132.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $164/yr $1,638 $4,504
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $426/yr $4,256 $11,701
California 29.75 ¢/kWh ($0.2975) $268/yr $2,683 $7,378
Texas 15.91 ¢/kWh ($0.1591) $144/yr $1,435 $3,946
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $132/yr $1,320 $3,628
Estimated electricity spend (902 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

What Should A. O. Smith Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC SaferProducts snapshot includes 4 filings tied to A. O. Smith; verify whether your HPTU-50N 1** production run falls inside affected ranges. See Serial Number Lookup.

4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #19030 (2018-11-08): A. O. Smith Recalls 30-Gallon Gas Water Heaters Due to Fire Hazard; Sold Exclusively at Lowe's (CPSC Notice)
  • Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
  • Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)

How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?

Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
American HPHE10250H045DVCTA-1** Hybrid/Electric Heat Pump 46 gal 66 gal 3.45 (at parity) 902
Lochinvar HPA052KD 1** Hybrid/Electric Heat Pump 46 gal 66 gal 3.45 (at parity) 902
RELIANCE WATER HEATERS 10-50-DHPHTCTA 1** Hybrid/Electric Heat Pump 46 gal 66 gal 3.45 (at parity) 902
State HPX-50-DHPTCTA 1** Hybrid/Electric Heat Pump 46 gal 66 gal 3.45 (at parity) 902
American HPHE10250H045DVDR 1** Hybrid/Electric Heat Pump 46 gal 66 gal 3.45 (at parity) 902

When Should Homeowners Skip A. O. Smith HPTU-50N 1** (Hybrid/Electric Heat Pump)?

Check A. O. Smith HPTU-50N 1**'s mechanical constraints—including utility space, Electric capacity, and Pass: +1.15 / +50.0% status—against typical residential installations.

Key Limitations & Exclusions

  • A. O. Smith HPTU-50N 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting A. O. Smith HPTU-50N 1** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing A. O. Smith HPTU-50N 1** Strong Fit — 3.45 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare American HPHE10250H045DVCTA-1** footprint.

Frequently Asked Technical Questions: A. O. Smith HPTU-50N 1**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Will A. O. Smith HPTU-50N 1** stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 3.45 UEF, A. O. Smith HPTU-50N 1** shows Pass: +1.15 / +50.0% relative to May 6, 2029 federal DOE limits while placing #563 of 706 among 706 Hybrid/Electric Heat Pump peers like American HPHE10250H045DVCTA-1**.

Will A. O. Smith HPTU-50N 1** fit through a standard utility door and 72-inch basement ceiling?

Measuring 63 in. tall by 15 in. diameter, A. O. Smith HPTU-50N 1** notes: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (15" d). Reserve space above the jacket for T&P piping and anode removal.

Do existing utility hookups support A. O. Smith HPTU-50N 1** during replacement?

Electrical specs for A. O. Smith HPTU-50N 1** call for 240V at 22A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.

What is the estimated 10-year operating spend for A. O. Smith HPTU-50N 1**?

At 18.16 cents/kWh national residential pricing, A. O. Smith HPTU-50N 1**'s 902 kWh/yr draw equals roughly $164 annually or $1,640 across a 10-year horizon (ranging from $132/yr in Washington hydro tiers up to $426/yr in Hawaii).

When is A. O. Smith HPTU-50N 1** a poor fit for a residential replacement?

Avoid placing A. O. Smith HPTU-50N 1** directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.

What First Hour Rating or flow capacity does A. O. Smith HPTU-50N 1** deliver?

With 66 gal FHR (-6 gal vs. 72 gal median), A. O. Smith HPTU-50N 1** fits larger 3–5 person homes cleanly.

How do you verify manufacturing age and recall status on A. O. Smith HPTU-50N 1**?

CPSC SaferProducts records show 4 brand-level recall notices mentioning A. O. Smith as of 2026-11-23, including #19030 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

Does A. O. Smith HPTU-50N 1** qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for A. O. Smith HPTU-50N 1**. Closest peer in Hybrid/Electric Heat Pump is American HPHE10250H045DVCTA-1** (3.45 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks