A. O. Smith HPTU-66N 1** Water Heater Specifications (3.45 UEF)
Engineered as a Electric Hybrid/Electric Heat Pump unit, A. O. Smith HPTU-66N 1** achieves a certified 3.45 UEF rating across its 67-gallon nominal tank, 79 gal First Hour Rating and ranks #563 of 706 in its 706-model cohort (PD 2408882), recording Pass: +0.95 / +38.0% under 2029 DOE rules. Rated annual electricity draw of 1,381 kWh/yr equates to roughly $251/yr ($2,508 over 10 years) at 18.16 cents/kWh. Closest certified alternative is American HPHE10266H045DVCTA-1** (3.45 UEF).
- Uniform Energy Factor
- 3.45 UEF
- Cohort UEF Rank
- #563 of 706
- First Hour Rating
- 79 gal
- Storage Volume
- 67 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +0.95 / +38.0%

Within the 706-unit Hybrid/Electric Heat Pump cohort, A. O. Smith HPTU-66N 1** logs 3.45 UEF and ranks #563 of 706.
Against 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF), A. O. Smith HPTU-66N 1** holds a +0.95 UEF (+38.0%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 1,381 kWh/yr for A. O. Smith HPTU-66N 1** runs ~$251/yr vs. ~$941/yr for a 0.92 UEF electric tank.
State electric sensitivity for A. O. Smith HPTU-66N 1**: 10-year operating spend spans $2,020 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,516 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Cross-shopping A. O. Smith HPTU-66N 1** (3.45 UEF)? Check American HPHE10266H045DVCTA-1** (3.45 UEF, at parity) and Lochinvar HPA068KD 1** (3.45 UEF, at parity).
Where Does A. O. Smith HPTU-66N 1** Rank Against Peer Hybrid/Electric Heat Pump Units?
Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, A. O. Smith HPTU-66N 1** holds #563 of 706; inspect footprint, circuit load, and efficiency deltas here.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | A. O. Smith | 144 certified listings | ENERGY STAR PD 2408882 |
| Model Number | HPTU-66N 1** | Draw pattern: High-Usage | HPTU-66N 1** |
| Uniform Energy Factor (UEF) | 3.45 | -0.25 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 79 gal | +7 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,381 kWh/yr | +309 kWh/yr vs. 1,072 kWh/yr median | Est. $251/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 265% | -164.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 61" H x 23" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 22 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2023-02-23 | Certified 2023-02-23 | Markets: United States, Canada |
How Much Electricity Does HPTU-66N 1** Use in Different States?
Estimated at $251/yr nationally (1,381 kWh/yr), 10-year utility spending for A. O. Smith HPTU-66N 1** shifts sharply between low-rate hydro and coastal grids.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $251/yr | $2,508 | $6,897 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $652/yr | $6,516 | $17,919 |
| California | 29.75 ¢/kWh ($0.2975) | $411/yr | $4,108 | $11,299 |
| Texas | 15.91 ¢/kWh ($0.1591) | $220/yr | $2,197 | $6,043 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $202/yr | $2,020 | $5,556 |
Does CPSC Flag Any Safety Notices on A. O. Smith Units?
Checking 2026-11-23 SaferProducts data shows 4 notices mentioning A. O. Smith; always cross-reference affected serial prefixes before ordering components. See Serial Number Lookup.
- Recall #19030 (2018-11-08): A. O. Smith Recalls 30-Gallon Gas Water Heaters Due to Fire Hazard; Sold Exclusively at Lowe's (CPSC Notice)
- Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
- Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
- Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)
Which Competing Hybrid/Electric Heat Pump Models Compare Closest to HPTU-66N 1**?
Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to A. O. Smith HPTU-66N 1**'s gallon capacity and 3.45 UEF efficiency.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| American HPHE10266H045DVCTA-1** | Hybrid/Electric Heat Pump | 67 gal | 79 gal | 3.45 (at parity) | 1,381 |
| Lochinvar HPA068KD 1** | Hybrid/Electric Heat Pump | 67 gal | 79 gal | 3.45 (at parity) | 1,381 |
| RELIANCE WATER HEATERS 10-66-DHPHTCTA 1** | Hybrid/Electric Heat Pump | 67 gal | 79 gal | 3.45 (at parity) | 1,381 |
| State HPX-66-DHPTCTA 1** | Hybrid/Electric Heat Pump | 67 gal | 79 gal | 3.45 (at parity) | 1,381 |
| American HPHE10266H045DVDR 1** | Hybrid/Electric Heat Pump | 67 gal | 79 gal | 3.45 (at parity) | 1,381 |
What Are the Limitations of A. O. Smith HPTU-66N 1** and Who Should Not Install It?
Before ordering A. O. Smith HPTU-66N 1** (Hybrid/Electric Heat Pump, 3.45 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.
Key Limitations & Exclusions
- A. O. Smith HPTU-66N 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting A. O. Smith HPTU-66N 1** directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Common Homeowner Questions for A. O. Smith HPTU-66N 1**
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Does A. O. Smith HPTU-66N 1** pass the May 6, 2029 federal DOE efficiency rule?
A. O. Smith HPTU-66N 1** carries a verified 3.45 UEF rating (Pass: +0.95 / +38.0%), ranking #563 of 706 across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.
What doorway width and ceiling height does A. O. Smith HPTU-66N 1** need?
A. O. Smith HPTU-66N 1** stands 61 in. high with a 23 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.
What gas pipe size or electrical breaker does A. O. Smith HPTU-66N 1** require?
A. O. Smith HPTU-66N 1** uses a 240V branch circuit at 22A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.
How much electricity or energy does A. O. Smith HPTU-66N 1** cost per year to run?
Rated at 1,381 kWh/yr, A. O. Smith HPTU-66N 1** costs about $251/yr ($2,510 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $202/yr in Washington hydro tiers up to $652/yr in Hawaii).
Who should NOT install A. O. Smith HPTU-66N 1**, and what are its limits?
A. O. Smith HPTU-66N 1** (3.45 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.
How many bathrooms or people can A. O. Smith HPTU-66N 1** serve at peak demand?
A. O. Smith HPTU-66N 1** achieves a 79 gal First Hour Rating (+7 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.
Are there CPSC safety recalls or serial checks for A. O. Smith HPTU-66N 1**?
CPSC SaferProducts records show 4 brand-level recall notices mentioning A. O. Smith as of 2026-11-23, including #19030 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
What 2026 rebates apply to A. O. Smith HPTU-66N 1**, and what peer compares closest?
Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is American HPHE10266H045DVCTA-1** (3.45 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)