Skip to main content
ENERGY STAR water heater model · PD 2408869

A. O. Smith HPTU-80CTA 1** Water Heater Specifications (3.45 UEF)

In the 706-unit Hybrid/Electric Heat Pump class, A. O. Smith HPTU-80CTA 1** (Electric) achieves a certified 3.45 UEF rating across its 82-gallon nominal tank, 86 gal First Hour Rating (rank #563 of 706, PD 2408869) and verifies as Pass: +0.95 / +38.0% for 2029 DOE floors. Rated annual electricity draw of 1,387 kWh/yr equates to roughly $252/yr ($2,519 over 10 years) at 18.16 cents/kWh. Closest certified alternative is American HPHE10280H045DVCTA-1** (3.45 UEF).

Uniform Energy Factor
3.45 UEF
Cohort UEF Rank
#563 of 706
First Hour Rating
86 gal
Storage Volume
82 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +0.95 / +38.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking A. O. Smith HPTU-80CTA 1** at 3.45 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50A. O. Smith HPTU-80CTA 1**: 3.45
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows A. O. Smith HPTU-80CTA 1** relative to the cohort median.
Efficiency comparison & rule summary

A. O. Smith HPTU-80CTA 1** records 3.45 UEF efficiency, putting it #563 of 706 among 706 Hybrid/Electric Heat Pump peers.

10 CFR 430.32(d)(2) compliance: A. O. Smith HPTU-80CTA 1** exceeds 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +0.95 UEF (+38.0%). At EIA August 2026 national rates (18.16 cents/kWh), 1,387 kWh/yr for A. O. Smith HPTU-80CTA 1** runs ~$252/yr vs. ~$945/yr for a 0.92 UEF electric tank.

State electric sensitivity for A. O. Smith HPTU-80CTA 1**: 10-year operating spend spans $2,029 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,544 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Competing options beside A. O. Smith HPTU-80CTA 1** (3.45 UEF) are American HPHE10280H045DVCTA-1** (3.45 UEF, at parity) and Lochinvar HPA082KD 1** (3.45 UEF, at parity).

What Physical and Thermal Ratings Define A. O. Smith HPTU-80CTA 1**?

Positioning at #563 of 706 out of 706 Hybrid/Electric Heat Pump peers, A. O. Smith HPTU-80CTA 1** pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandA. O. Smith144 certified listingsENERGY STAR PD 2408869
Model NumberHPTU-80CTA 1**Draw pattern: High-UsageHPTU-80CTA 1**
Uniform Energy Factor (UEF)3.45-0.25 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)86 gal+14 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,387 kWh/yr+315 kWh/yr vs. 1,072 kWh/yr medianEst. $252/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency233%-196.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)69" H x 27" DVerify 72 in. vertical headroom; tight at 28 in. door (27" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 22 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2023-02-23Certified 2023-02-23Markets: United States, Canada

Why Do State Utility Rates Shift HPTU-80CTA 1** Running Costs?

Consuming 1,387 kWh annually puts A. O. Smith HPTU-80CTA 1** near $252/yr at US baseline tariffs, with multi-state EIA comparisons charted below.

Estimated Annual Electricity Cost by State Rate (1,387 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$252.00/yrHawaii$654.00/yrCalifornia$413.00/yrTexas$221.00/yrWashington$203.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $252/yr $2,519 $6,926
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $654/yr $6,544 $17,994
California 29.75 ¢/kWh ($0.2975) $413/yr $4,126 $11,347
Texas 15.91 ¢/kWh ($0.1591) $221/yr $2,207 $6,068
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $203/yr $2,029 $5,580
Estimated electricity spend (1,387 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Have Any A. O. Smith Series Triggered CPSC Recalls?

SaferProducts records retrieved 2026-11-23 list 4 brand notices under A. O. Smith; inspect model coverage dates prior to valve or anode service. See Serial Number Lookup.

4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #19030 (2018-11-08): A. O. Smith Recalls 30-Gallon Gas Water Heaters Due to Fire Hazard; Sold Exclusively at Lowe's (CPSC Notice)
  • Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
  • Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)

What Are 5 Direct Alternatives to A. O. Smith HPTU-80CTA 1**?

Homeowners cross-shopping A. O. Smith HPTU-80CTA 1** frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
American HPHE10280H045DVCTA-1** Hybrid/Electric Heat Pump 82 gal 86 gal 3.45 (at parity) 1,387
Lochinvar HPA082KD 1** Hybrid/Electric Heat Pump 82 gal 86 gal 3.45 (at parity) 1,387
RELIANCE WATER HEATERS 10-80-DHPHTCTA 1** Hybrid/Electric Heat Pump 82 gal 86 gal 3.45 (at parity) 1,387
State HPX-80-DHPTCTA 1** Hybrid/Electric Heat Pump 82 gal 86 gal 3.45 (at parity) 1,387
American HPHE10280H045DVDR 1** Hybrid/Electric Heat Pump 82 gal 86 gal 3.45 (at parity) 1,387

Which Home Setups Are NOT a Fit for A. O. Smith HPTU-80CTA 1**?

Comparing A. O. Smith HPTU-80CTA 1** against American HPHE10280H045DVCTA-1** requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

Key Limitations & Exclusions

  • A. O. Smith HPTU-80CTA 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting A. O. Smith HPTU-80CTA 1** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing A. O. Smith HPTU-80CTA 1** Strong Fit — 3.45 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare American HPHE10280H045DVCTA-1** footprint.

Sizing, Efficiency & Recall Answers for A. O. Smith HPTU-80CTA 1**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does A. O. Smith HPTU-80CTA 1** score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; A. O. Smith HPTU-80CTA 1** logs 3.45 UEF (Pass: +0.95 / +38.0%) within the 706-unit Hybrid/Electric Heat Pump group.

What physical clearance dimensions apply when installing A. O. Smith HPTU-80CTA 1**?

With a 69 in. height and 27 in. diameter, A. O. Smith HPTU-80CTA 1** fits spaces matching: verify 72 in. vertical headroom; tight at 28 in. door (27" d), plus 6–12 in. above for plumbing shutoffs.

What 240V circuit or IFGC fuel line capacity fits A. O. Smith HPTU-80CTA 1**?

Powered via 240V at 22A max, A. O. Smith HPTU-80CTA 1** requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.

How do state electricity prices change annual costs for A. O. Smith HPTU-80CTA 1**?

Annual electric spend for A. O. Smith HPTU-80CTA 1** (1,387 kWh/yr) averages $252/yr nationwide (ranging from $203/yr in Washington hydro tiers up to $654/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.

What homeowner setups should avoid choosing A. O. Smith HPTU-80CTA 1**?

Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on A. O. Smith HPTU-80CTA 1**.

Is A. O. Smith HPTU-80CTA 1** sized adequately for a 2-to-4-person household?

ENERGY STAR certifies A. O. Smith HPTU-80CTA 1** at 86 gal First Hour Rating (+14 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.

Does A. O. Smith have active CPSC SaferProducts notices affecting HPTU-80CTA 1**?

CPSC SaferProducts records show 4 brand-level recall notices mentioning A. O. Smith as of 2026-11-23, including #19030 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

Which competing water heater matches A. O. Smith HPTU-80CTA 1** (3.45 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for A. O. Smith HPTU-80CTA 1**. Closest peer in Hybrid/Electric Heat Pump is American HPHE10280H045DVCTA-1** (3.45 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks