A. O. Smith HPTU-80DR 1** Water Heater Specifications (3.45 UEF)
Engineered as a Electric Hybrid/Electric Heat Pump unit, A. O. Smith HPTU-80DR 1** achieves a certified 3.45 UEF rating across its 82-gallon nominal tank, 86 gal First Hour Rating and ranks #563 of 706 in its 706-model cohort (PD 2408862), recording Pass: +0.95 / +38.0% under 2029 DOE rules. Rated annual electricity draw of 1,387 kWh/yr equates to roughly $252/yr ($2,519 over 10 years) at 18.16 cents/kWh. Closest certified alternative is American HPHE10280H045DVCTA-1** (3.45 UEF).
- Uniform Energy Factor
- 3.45 UEF
- Cohort UEF Rank
- #563 of 706
- First Hour Rating
- 86 gal
- Storage Volume
- 82 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +0.95 / +38.0%

Within the 706-unit Hybrid/Electric Heat Pump cohort, A. O. Smith HPTU-80DR 1** logs 3.45 UEF and ranks #563 of 706.
Against 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF), A. O. Smith HPTU-80DR 1** holds a +0.95 UEF (+38.0%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 1,387 kWh/yr for A. O. Smith HPTU-80DR 1** runs ~$252/yr vs. ~$945/yr for a 0.92 UEF electric tank.
State electric sensitivity for A. O. Smith HPTU-80DR 1**: 10-year operating spend spans $2,029 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,544 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Cross-shopping A. O. Smith HPTU-80DR 1** (3.45 UEF)? Check American HPHE10280H045DVCTA-1** (3.45 UEF, at parity) and Lochinvar HPA082KD 1** (3.45 UEF, at parity).
Which Specs Set A. O. Smith HPTU-80DR 1** Apart From Cohort Averages?
Ranked #563 of 706 inside the 706-model Hybrid/Electric Heat Pump cohort, A. O. Smith HPTU-80DR 1** is evaluated row by row below against category medians.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | A. O. Smith | 144 certified listings | ENERGY STAR PD 2408862 |
| Model Number | HPTU-80DR 1** | Draw pattern: High-Usage | HPTU-80DR 1** |
| Uniform Energy Factor (UEF) | 3.45 | -0.25 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 86 gal | +14 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,387 kWh/yr | +315 kWh/yr vs. 1,072 kWh/yr median | Est. $252/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 233% | -196.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 69" H x 27" D | Verify 72 in. vertical headroom; tight at 28 in. door (27" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 22 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2023-02-23 | Certified 2023-02-23 | Markets: United States, Canada |
How Do Regional kWh Prices Impact HPTU-80DR 1** Over 10 Years?
Using EIA Table 5.6.A benchmarks, A. O. Smith HPTU-80DR 1**'s 1,387 kWh/yr draw translates to roughly $252/yr on typical US residential bills.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $252/yr | $2,519 | $6,926 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $654/yr | $6,544 | $17,994 |
| California | 29.75 ¢/kWh ($0.2975) | $413/yr | $4,126 | $11,347 |
| Texas | 15.91 ¢/kWh ($0.1591) | $221/yr | $2,207 | $6,068 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $203/yr | $2,029 | $5,580 |
What Should A. O. Smith Owners Check in CPSC Recall Logs?
The 2026-11-23 CPSC SaferProducts snapshot includes 4 filings tied to A. O. Smith; verify whether your HPTU-80DR 1** production run falls inside affected ranges. See Serial Number Lookup.
- Recall #19030 (2018-11-08): A. O. Smith Recalls 30-Gallon Gas Water Heaters Due to Fire Hazard; Sold Exclusively at Lowe's (CPSC Notice)
- Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
- Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
- Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)
How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?
Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| American HPHE10280H045DVCTA-1** | Hybrid/Electric Heat Pump | 82 gal | 86 gal | 3.45 (at parity) | 1,387 |
| Lochinvar HPA082KD 1** | Hybrid/Electric Heat Pump | 82 gal | 86 gal | 3.45 (at parity) | 1,387 |
| RELIANCE WATER HEATERS 10-80-DHPHTCTA 1** | Hybrid/Electric Heat Pump | 82 gal | 86 gal | 3.45 (at parity) | 1,387 |
| State HPX-80-DHPTCTA 1** | Hybrid/Electric Heat Pump | 82 gal | 86 gal | 3.45 (at parity) | 1,387 |
| American HPHE10280H045DVDR 1** | Hybrid/Electric Heat Pump | 82 gal | 86 gal | 3.45 (at parity) | 1,387 |
Which Home Setups Are NOT a Fit for A. O. Smith HPTU-80DR 1**?
Comparing A. O. Smith HPTU-80DR 1** against American HPHE10280H045DVCTA-1** requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.
Key Limitations & Exclusions
- A. O. Smith HPTU-80DR 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting A. O. Smith HPTU-80DR 1** directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Frequently Asked Technical Questions: A. O. Smith HPTU-80DR 1**
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
How does A. O. Smith HPTU-80DR 1** score under 10 CFR 430.32 May 2029 water heater minimums?
Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; A. O. Smith HPTU-80DR 1** logs 3.45 UEF (Pass: +0.95 / +38.0%) within the 706-unit Hybrid/Electric Heat Pump group.
What physical clearance dimensions apply when installing A. O. Smith HPTU-80DR 1**?
With a 69 in. height and 27 in. diameter, A. O. Smith HPTU-80DR 1** fits spaces matching: verify 72 in. vertical headroom; tight at 28 in. door (27" d), plus 6–12 in. above for plumbing shutoffs.
What 240V circuit or IFGC fuel line capacity fits A. O. Smith HPTU-80DR 1**?
Powered via 240V at 22A max, A. O. Smith HPTU-80DR 1** requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.
How do state electricity prices change annual costs for A. O. Smith HPTU-80DR 1**?
Annual electric spend for A. O. Smith HPTU-80DR 1** (1,387 kWh/yr) averages $252/yr nationwide (ranging from $203/yr in Washington hydro tiers up to $654/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.
What homeowner setups should avoid choosing A. O. Smith HPTU-80DR 1**?
Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on A. O. Smith HPTU-80DR 1**.
Is A. O. Smith HPTU-80DR 1** sized adequately for a 2-to-4-person household?
ENERGY STAR certifies A. O. Smith HPTU-80DR 1** at 86 gal First Hour Rating (+14 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.
Does A. O. Smith have active CPSC SaferProducts notices affecting HPTU-80DR 1**?
CPSC SaferProducts records show 4 brand-level recall notices mentioning A. O. Smith as of 2026-11-23, including #19030 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
Which competing water heater matches A. O. Smith HPTU-80DR 1** (3.45 UEF) most closely?
State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for A. O. Smith HPTU-80DR 1**. Closest peer in Hybrid/Electric Heat Pump is American HPHE10280H045DVCTA-1** (3.45 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)