Skip to main content
ENERGY STAR water heater model · PD 2408861

A. O. Smith HPTU-80N 1** Water Heater Specifications (3.45 UEF)

Certified at 3.45 UEF across its 82-gallon nominal tank, 86 gal First Hour Rating, A. O. Smith HPTU-80N 1** (Hybrid/Electric Heat Pump, Electric) places #563 of 706 out of 706 ENERGY STAR models (PD 2408861). Its May 6, 2029 10 CFR 430.32 status reads Pass: +0.95 / +38.0%. Rated annual electricity draw of 1,387 kWh/yr equates to roughly $252/yr ($2,519 over 10 years) at 18.16 cents/kWh. Closest certified alternative is American HPHE10280H045DVCTA-1** (3.45 UEF).

Uniform Energy Factor
3.45 UEF
Cohort UEF Rank
#563 of 706
First Hour Rating
86 gal
Storage Volume
82 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +0.95 / +38.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking A. O. Smith HPTU-80N 1** at 3.45 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50A. O. Smith HPTU-80N 1**: 3.45
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows A. O. Smith HPTU-80N 1** relative to the cohort median.
Efficiency comparison & rule summary

Tested at 3.45 UEF, A. O. Smith HPTU-80N 1** places #563 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (-0.25 UEF vs. 3.70 UEF median).

A. O. Smith HPTU-80N 1** clears 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +0.95 UEF (+38.0% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 1,387 kWh/yr for A. O. Smith HPTU-80N 1** runs ~$252/yr vs. ~$945/yr for a 0.92 UEF electric tank.

State electric sensitivity for A. O. Smith HPTU-80N 1**: 10-year operating spend spans $2,029 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,544 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Closest alternatives to A. O. Smith HPTU-80N 1** include American HPHE10280H045DVCTA-1** (3.45 UEF, at parity) alongside Lochinvar HPA082KD 1** (3.45 UEF, at parity).

How Complete Are the Certified Metrics for A. O. Smith HPTU-80N 1**?

Standing at #563 of 706 among 706 certified Hybrid/Electric Heat Pump heaters, A. O. Smith HPTU-80N 1** brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandA. O. Smith144 certified listingsENERGY STAR PD 2408861
Model NumberHPTU-80N 1**Draw pattern: High-UsageHPTU-80N 1**
Uniform Energy Factor (UEF)3.45-0.25 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)86 gal+14 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,387 kWh/yr+315 kWh/yr vs. 1,072 kWh/yr medianEst. $252/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency233%-196.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)69" H x 27" DVerify 72 in. vertical headroom; tight at 28 in. door (27" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 22 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2023-02-23Certified 2023-02-23Markets: United States, Canada

What Is the Projected Utility Bill for HPTU-80N 1** by State?

At 1,387 kWh/yr, A. O. Smith HPTU-80N 1** averages about $252/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.

Estimated Annual Electricity Cost by State Rate (1,387 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$252.00/yrHawaii$654.00/yrCalifornia$413.00/yrTexas$221.00/yrWashington$203.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $252/yr $2,519 $6,926
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $654/yr $6,544 $17,994
California 29.75 ¢/kWh ($0.2975) $413/yr $4,126 $11,347
Texas 15.91 ¢/kWh ($0.1591) $221/yr $2,207 $6,068
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $203/yr $2,029 $5,580
Estimated electricity spend (1,387 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are A. O. Smith Models Affected by Current CPSC Notices?

Review 4 brand-matched CPSC entries pulled 2026-11-23 for A. O. Smith and confirm your serial tag before scheduling contractor service. See Serial Number Lookup.

4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #19030 (2018-11-08): A. O. Smith Recalls 30-Gallon Gas Water Heaters Due to Fire Hazard; Sold Exclusively at Lowe's (CPSC Notice)
  • Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
  • Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)

Which 5 Models Offer Similar Output to HPTU-80N 1**?

Ordered by minimal capacity and UEF spread relative to A. O. Smith HPTU-80N 1**, these five certified peers give direct replacement benchmarks.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
American HPHE10280H045DVCTA-1** Hybrid/Electric Heat Pump 82 gal 86 gal 3.45 (at parity) 1,387
Lochinvar HPA082KD 1** Hybrid/Electric Heat Pump 82 gal 86 gal 3.45 (at parity) 1,387
RELIANCE WATER HEATERS 10-80-DHPHTCTA 1** Hybrid/Electric Heat Pump 82 gal 86 gal 3.45 (at parity) 1,387
State HPX-80-DHPTCTA 1** Hybrid/Electric Heat Pump 82 gal 86 gal 3.45 (at parity) 1,387
American HPHE10280H045DVDR 1** Hybrid/Electric Heat Pump 82 gal 86 gal 3.45 (at parity) 1,387

When Should Homeowners Skip A. O. Smith HPTU-80N 1** (Hybrid/Electric Heat Pump)?

Check A. O. Smith HPTU-80N 1**'s mechanical constraints—including utility space, Electric capacity, and Pass: +0.95 / +38.0% status—against typical residential installations.

Key Limitations & Exclusions

  • A. O. Smith HPTU-80N 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting A. O. Smith HPTU-80N 1** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing A. O. Smith HPTU-80N 1** Strong Fit — 3.45 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare American HPHE10280H045DVCTA-1** footprint.

Practical Specs & Code Questions for A. O. Smith HPTU-80N 1**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Will A. O. Smith HPTU-80N 1** stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 3.45 UEF, A. O. Smith HPTU-80N 1** shows Pass: +0.95 / +38.0% relative to May 6, 2029 federal DOE limits while placing #563 of 706 among 706 Hybrid/Electric Heat Pump peers like American HPHE10280H045DVCTA-1**.

Will A. O. Smith HPTU-80N 1** fit through a standard utility door and 72-inch basement ceiling?

Measuring 69 in. tall by 27 in. diameter, A. O. Smith HPTU-80N 1** notes: verify 72 in. vertical headroom; tight at 28 in. door (27" d). Reserve space above the jacket for T&P piping and anode removal.

Do existing utility hookups support A. O. Smith HPTU-80N 1** during replacement?

Electrical specs for A. O. Smith HPTU-80N 1** call for 240V at 22A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.

What is the estimated 10-year operating spend for A. O. Smith HPTU-80N 1**?

At 18.16 cents/kWh national residential pricing, A. O. Smith HPTU-80N 1**'s 1,387 kWh/yr draw equals roughly $252 annually or $2,520 across a 10-year horizon (ranging from $203/yr in Washington hydro tiers up to $654/yr in Hawaii).

When is A. O. Smith HPTU-80N 1** a poor fit for a residential replacement?

Avoid placing A. O. Smith HPTU-80N 1** directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.

What First Hour Rating or flow capacity does A. O. Smith HPTU-80N 1** deliver?

With 86 gal FHR (+14 gal vs. 72 gal median), A. O. Smith HPTU-80N 1** fits larger 3–5 person homes cleanly.

How do you verify manufacturing age and recall status on A. O. Smith HPTU-80N 1**?

CPSC SaferProducts records show 4 brand-level recall notices mentioning A. O. Smith as of 2026-11-23, including #19030 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

Does A. O. Smith HPTU-80N 1** qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for A. O. Smith HPTU-80N 1**. Closest peer in Hybrid/Electric Heat Pump is American HPHE10280H045DVCTA-1** (3.45 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks