Skip to main content
ENERGY STAR water heater model · PD 2546252

A. O. Smith HPTV-66 2** Water Heater Specifications (3.2 UEF)

Engineered as a Electric Hybrid/Electric Heat Pump unit, A. O. Smith HPTV-66 2** achieves a certified 3.2 UEF rating across its 68-gallon nominal tank, 76 gal First Hour Rating and ranks #646 of 706 in its 706-model cohort (PD 2546252), recording Pass: +0.70 / +28.0% under 2029 DOE rules. Rated annual electricity draw of 1,550 kWh/yr equates to roughly $281/yr ($2,815 over 10 years) at 18.16 cents/kWh. Closest certified alternative is American HPV10266H009DV 2** (3.2 UEF).

Uniform Energy Factor
3.2 UEF
Cohort UEF Rank
#646 of 706
First Hour Rating
76 gal
Storage Volume
68 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +0.70 / +28.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking A. O. Smith HPTV-66 2** at 3.2 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50A. O. Smith HPTV-66 2**: 3.20
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows A. O. Smith HPTV-66 2** relative to the cohort median.
Efficiency comparison & rule summary

Within the 706-unit Hybrid/Electric Heat Pump cohort, A. O. Smith HPTV-66 2** logs 3.2 UEF and ranks #646 of 706.

Against 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF), A. O. Smith HPTV-66 2** holds a +0.70 UEF (+28.0%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 1,550 kWh/yr for A. O. Smith HPTV-66 2** runs ~$281/yr vs. ~$979/yr for a 0.92 UEF electric tank. Acoustic output is 45 dBA (quieter than 69.1% of Hybrid/Electric Heat Pump models).

State electric sensitivity for A. O. Smith HPTV-66 2**: 10-year operating spend spans $2,268 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $7,313 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Cross-shopping A. O. Smith HPTV-66 2** (3.2 UEF)? Check American HPV10266H009DV 2** (3.2 UEF, at parity) and Lochinvar HPV065KD 2** (3.2 UEF, at parity).

Where Does A. O. Smith HPTV-66 2** Rank Against Peer Hybrid/Electric Heat Pump Units?

Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, A. O. Smith HPTV-66 2** holds #646 of 706; inspect footprint, circuit load, and efficiency deltas here.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandA. O. Smith144 certified listingsENERGY STAR PD 2546252
Model NumberHPTV-66 2**Draw pattern: High-UsageHPTV-66 2**
Uniform Energy Factor (UEF)3.2-0.50 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)76 gal+4 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,550 kWh/yr+478 kWh/yr vs. 1,072 kWh/yr medianEst. $281/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency368%-61.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)61" H x 23" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" D)Doorway & ceiling check
Electrical Circuit Requirements120 V / 15 A max120V plug-in retrofit circuit; slower heat-pump-only recoveryNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-513A (GWP:630)Lower-GWP refrigerant alignment (EPA AIM Act)EPA AIM Act Compliance
Sound Pressure Level45 dBAtop 30.9% · quieter than 69.1% of Hybrid/Electric Heat Pump models · -4 dBA vs. 49 dBA medianIndoor placement check
Certification Date2025-12-12Certified 2025-12-12Markets: United States

How Much Electricity Does HPTV-66 2** Use in Different States?

Estimated at $281/yr nationally (1,550 kWh/yr), 10-year utility spending for A. O. Smith HPTV-66 2** shifts sharply between low-rate hydro and coastal grids.

Estimated Annual Electricity Cost by State Rate (1,550 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$281.00/yrHawaii$731.00/yrCalifornia$461.00/yrTexas$247.00/yrWashington$227.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $281/yr $2,815 $6,975
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $731/yr $7,313 $18,122
California 29.75 ¢/kWh ($0.2975) $461/yr $4,611 $11,427
Texas 15.91 ¢/kWh ($0.1591) $247/yr $2,466 $6,111
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $227/yr $2,268 $5,619
Estimated electricity spend (1,550 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Does CPSC Flag Any Safety Notices on A. O. Smith Units?

Checking 2026-11-23 SaferProducts data shows 4 notices mentioning A. O. Smith; always cross-reference affected serial prefixes before ordering components. See Serial Number Lookup.

4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #19030 (2018-11-08): A. O. Smith Recalls 30-Gallon Gas Water Heaters Due to Fire Hazard; Sold Exclusively at Lowe's (CPSC Notice)
  • Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
  • Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)

Which Competing Hybrid/Electric Heat Pump Models Compare Closest to HPTV-66 2**?

Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to A. O. Smith HPTV-66 2**'s gallon capacity and 3.2 UEF efficiency.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
American HPV10266H009DV 2** Hybrid/Electric Heat Pump 68 gal 76 gal 3.2 (at parity) 1,550
Lochinvar HPV065KD 2** Hybrid/Electric Heat Pump 68 gal 76 gal 3.2 (at parity) 1,550
RELIANCE WATER HEATERS 10-66-DHPTV 2** Hybrid/Electric Heat Pump 68 gal 76 gal 3.2 (at parity) 1,550
State HPVX-66-DHPT 2** Hybrid/Electric Heat Pump 68 gal 76 gal 3.2 (at parity) 1,550
American HPA10266H045DV 2** Hybrid/Electric Heat Pump 68 gal 83 gal 3.84 (+0.64) 1,292

What Installation Caveats Apply Before Buying A. O. Smith HPTV-66 2**?

Even high-UEF units like A. O. Smith HPTV-66 2** (3.2 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

Key Limitations & Exclusions

  • A. O. Smith HPTV-66 2** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 45 dBA; avoid mounting A. O. Smith HPTV-66 2** directly beside quiet bedrooms.
  • Requires condensate drain routing and 120V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing A. O. Smith HPTV-66 2** Strong Fit — 3.2 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare American HPV10266H009DV 2** footprint.

Common Homeowner Questions for A. O. Smith HPTV-66 2**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Is A. O. Smith HPTV-66 2** eligible for continued manufacture past May 6, 2029?

At 3.2 UEF, A. O. Smith HPTV-66 2** achieves Pass: +0.70 / +28.0% for the 2029 DOE standard and stands #646 of 706 against American HPV10266H009DV 2** and Lochinvar HPV065KD 2**.

How tall and wide is A. O. Smith HPTV-66 2**, and what service clearance is needed?

Physical dimensions for A. O. Smith HPTV-66 2** are 61 in. height and 23 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" d)); verify stair turns and drain pan width before delivery.

Will A. O. Smith HPTV-66 2** require upgrading household electrical panels or gas piping?

A. O. Smith HPTV-66 2** draws 120V at 15A max (120V plug-in retrofit circuit; slower heat-pump-only recovery); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.

Is A. O. Smith HPTV-66 2** economical to operate at 18.16 cents/kWh US electric rates?

Expect roughly $281/yr ($2,810 over 10 years) to power A. O. Smith HPTV-66 2** at 1,550 kWh/yr under the 18.16 cents/kWh US average (ranging from $227/yr in Washington hydro tiers up to $731/yr in Hawaii).

Which installation bottlenecks limit A. O. Smith HPTV-66 2**?

If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, A. O. Smith HPTV-66 2** drops into resistance mode more often.

How does A. O. Smith HPTV-66 2** handle simultaneous showers and laundry?

Delivering 76 gal in the first hour (+4 gal vs. 72 gal median), A. O. Smith HPTV-66 2** combines 68 gal tank storage with rapid burner/element recovery.

How long is the warranty on A. O. Smith HPTV-66 2** and how do you decode its serial?

CPSC SaferProducts records show 4 brand-level recall notices mentioning A. O. Smith as of 2026-11-23, including #19030 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

How do 2026 post-OBBBA rebates affect buying A. O. Smith HPTV-66 2**?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is American HPV10266H009DV 2** (3.2 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks