ENERGY STAR water heater model · PD 2670091

RELIANCE WATER HEATERS 10-66-DHPTV 2** Water Heater Specifications (3.2 UEF)

Certified at 3.2 UEF across its 68-gallon nominal tank, 76 gal First Hour Rating, RELIANCE WATER HEATERS 10-66-DHPTV 2** (Hybrid/Electric Heat Pump, Electric) places #646 of 706 out of 706 ENERGY STAR models (PD 2670091). Its May 6, 2029 10 CFR 430.32 status reads Pass: +0.70 / +28.0%. Rated annual electricity draw of 1,550 kWh/yr equates to roughly $281/yr ($2,815 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPTV-66 2** (3.2 UEF).

Uniform Energy Factor
3.2 UEF
Cohort UEF Rank
#646 of 706
First Hour Rating
76 gal
Storage Volume
68 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +0.70 / +28.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking RELIANCE WATER HEATERS 10-66-DHPTV 2** at 3.2 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50RELIANCE WATER HEATERS 10-66-DHPTV 2**: 3.20
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows RELIANCE WATER HEATERS 10-66-DHPTV 2** relative to the cohort median.
Efficiency comparison & rule summary

Tested at 3.2 UEF, RELIANCE WATER HEATERS 10-66-DHPTV 2** places #646 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (-0.50 UEF vs. 3.70 UEF median).

RELIANCE WATER HEATERS 10-66-DHPTV 2** clears 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +0.70 UEF (+28.0% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 1,550 kWh/yr for RELIANCE WATER HEATERS 10-66-DHPTV 2** runs ~$281/yr vs. ~$979/yr for a 0.92 UEF electric tank. Acoustic output is 45 dBA (quieter than 69.1% of Hybrid/Electric Heat Pump models).

State electric sensitivity for RELIANCE WATER HEATERS 10-66-DHPTV 2**: 10-year operating spend spans $2,268 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $7,313 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Closest alternatives to RELIANCE WATER HEATERS 10-66-DHPTV 2** include A. O. Smith HPTV-66 2** (3.2 UEF, at parity) alongside American HPV10266H009DV 2** (3.2 UEF, at parity).

Where Does RELIANCE WATER HEATERS 10-66-DHPTV 2** Rank Against Peer Hybrid/Electric Heat Pump Units?

Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, RELIANCE WATER HEATERS 10-66-DHPTV 2** holds #646 of 706; inspect footprint, circuit load, and efficiency deltas here.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRELIANCE WATER HEATERS71 certified listingsENERGY STAR PD 2670091
Model Number10-66-DHPTV 2**Draw pattern: High-Usage10-66-DHPTV 2**
Uniform Energy Factor (UEF)3.2-0.50 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)76 gal+4 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,550 kWh/yr+478 kWh/yr vs. 1,072 kWh/yr medianEst. $281/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency368%-61.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)61" H x 23" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" D)Doorway & ceiling check
Electrical Circuit Requirements120 V / 15 A max120V plug-in retrofit circuit; slower heat-pump-only recoveryNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-513A (GWP:630)Lower-GWP refrigerant alignment (EPA AIM Act)EPA AIM Act Compliance
Sound Pressure Level45 dBAtop 30.9% · quieter than 69.1% of Hybrid/Electric Heat Pump models · -4 dBA vs. 49 dBA medianIndoor placement check
Certification Date2025-12-12Certified 2025-12-12Markets: United States

How Much Electricity Does 10-66-DHPTV 2** Use in Different States?

Estimated at $281/yr nationally (1,550 kWh/yr), 10-year utility spending for RELIANCE WATER HEATERS 10-66-DHPTV 2** shifts sharply between low-rate hydro and coastal grids.

Estimated Annual Electricity Cost by State Rate (1,550 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$281.00/yrHawaii$731.00/yrCalifornia$461.00/yrTexas$247.00/yrWashington$227.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $281/yr $2,815 $6,975
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $731/yr $7,313 $18,122
California 29.75 ¢/kWh ($0.2975) $461/yr $4,611 $11,427
Texas 15.91 ¢/kWh ($0.1591) $247/yr $2,466 $6,111
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $227/yr $2,268 $5,619
Estimated electricity spend (1,550 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Does CPSC Flag Any Safety Notices on RELIANCE WATER HEATERS Units?

Checking 2026-11-23 SaferProducts data shows 3 notices mentioning RELIANCE WATER HEATERS; always cross-reference affected serial prefixes before ordering components. See Serial Number Lookup.

3 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
  • Recall #04128 (2004-04-28): CPSC, White-Rodgers Announce Recall of LP and Convertible Gas Water Heater Temperature Controls (CPSC Notice)

Which Competing Hybrid/Electric Heat Pump Models Compare Closest to 10-66-DHPTV 2**?

Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to RELIANCE WATER HEATERS 10-66-DHPTV 2**'s gallon capacity and 3.2 UEF efficiency.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith HPTV-66 2** Hybrid/Electric Heat Pump 68 gal 76 gal 3.2 (at parity) 1,550
American HPV10266H009DV 2** Hybrid/Electric Heat Pump 68 gal 76 gal 3.2 (at parity) 1,550
Lochinvar HPV065KD 2** Hybrid/Electric Heat Pump 68 gal 76 gal 3.2 (at parity) 1,550
State HPVX-66-DHPT 2** Hybrid/Electric Heat Pump 68 gal 76 gal 3.2 (at parity) 1,550
A. O. Smith HPV10-66H01DV 2** Hybrid/Electric Heat Pump 68 gal 76 gal 3.2 (at parity) 1,550

When Should Homeowners Skip RELIANCE WATER HEATERS 10-66-DHPTV 2** (Hybrid/Electric Heat Pump)?

Check RELIANCE WATER HEATERS 10-66-DHPTV 2**'s mechanical constraints—including utility space, Electric capacity, and Pass: +0.70 / +28.0% status—against typical residential installations.

Key Limitations & Exclusions

  • RELIANCE WATER HEATERS 10-66-DHPTV 2** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 45 dBA; avoid mounting RELIANCE WATER HEATERS 10-66-DHPTV 2** directly beside quiet bedrooms.
  • Requires condensate drain routing and 120V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing RELIANCE WATER HEATERS 10-66-DHPTV 2** Strong Fit — 3.2 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare A. O. Smith HPTV-66 2** footprint.

Common Homeowner Questions for RELIANCE WATER HEATERS 10-66-DHPTV 2**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Will RELIANCE WATER HEATERS 10-66-DHPTV 2** stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 3.2 UEF, RELIANCE WATER HEATERS 10-66-DHPTV 2** shows Pass: +0.70 / +28.0% relative to May 6, 2029 federal DOE limits while placing #646 of 706 among 706 Hybrid/Electric Heat Pump peers like A. O. Smith HPTV-66 2**.

Will RELIANCE WATER HEATERS 10-66-DHPTV 2** fit through a standard utility door and 72-inch basement ceiling?

Measuring 61 in. tall by 23 in. diameter, RELIANCE WATER HEATERS 10-66-DHPTV 2** notes: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" d). Reserve space above the jacket for T&P piping and anode removal.

Do existing utility hookups support RELIANCE WATER HEATERS 10-66-DHPTV 2** during replacement?

Electrical specs for RELIANCE WATER HEATERS 10-66-DHPTV 2** call for 120V at 15A max (120V plug-in retrofit circuit; slower heat-pump-only recovery). Have a licensed electrician inspect panel load and wire gauge.

What is the estimated 10-year operating spend for RELIANCE WATER HEATERS 10-66-DHPTV 2**?

At 18.16 cents/kWh national residential pricing, RELIANCE WATER HEATERS 10-66-DHPTV 2**'s 1,550 kWh/yr draw equals roughly $281 annually or $2,810 across a 10-year horizon (ranging from $227/yr in Washington hydro tiers up to $731/yr in Hawaii).

When is RELIANCE WATER HEATERS 10-66-DHPTV 2** a poor fit for a residential replacement?

Avoid placing RELIANCE WATER HEATERS 10-66-DHPTV 2** directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 45 dBA sound and cool exhaust airflow.

What First Hour Rating or flow capacity does RELIANCE WATER HEATERS 10-66-DHPTV 2** deliver?

With 76 gal FHR (+4 gal vs. 72 gal median), RELIANCE WATER HEATERS 10-66-DHPTV 2** fits larger 3–5 person homes cleanly.

How do you verify manufacturing age and recall status on RELIANCE WATER HEATERS 10-66-DHPTV 2**?

CPSC SaferProducts records show 3 brand-level recall notices mentioning RELIANCE WATER HEATERS as of 2026-11-23, including #19029 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

Does RELIANCE WATER HEATERS 10-66-DHPTV 2** qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for RELIANCE WATER HEATERS 10-66-DHPTV 2**. Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPTV-66 2** (3.2 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks