Skip to main content
ENERGY STAR water heater model · PD 2546249

State HPVX-66-DHPT 2** Water Heater Specifications (3.2 UEF)

In the 706-unit Hybrid/Electric Heat Pump class, State HPVX-66-DHPT 2** (Electric) achieves a certified 3.2 UEF rating across its 68-gallon nominal tank, 76 gal First Hour Rating (rank #646 of 706, PD 2546249) and verifies as Pass: +0.70 / +28.0% for 2029 DOE floors. Rated annual electricity draw of 1,550 kWh/yr equates to roughly $281/yr ($2,815 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPTV-66 2** (3.2 UEF).

Uniform Energy Factor
3.2 UEF
Cohort UEF Rank
#646 of 706
First Hour Rating
76 gal
Storage Volume
68 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +0.70 / +28.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking State HPVX-66-DHPT 2** at 3.2 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50State HPVX-66-DHPT 2**: 3.20
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows State HPVX-66-DHPT 2** relative to the cohort median.
Efficiency comparison & rule summary

State HPVX-66-DHPT 2** records 3.2 UEF efficiency, putting it #646 of 706 among 706 Hybrid/Electric Heat Pump peers.

10 CFR 430.32(d)(2) compliance: State HPVX-66-DHPT 2** exceeds 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +0.70 UEF (+28.0%). At EIA August 2026 national rates (18.16 cents/kWh), 1,550 kWh/yr for State HPVX-66-DHPT 2** runs ~$281/yr vs. ~$979/yr for a 0.92 UEF electric tank. Acoustic output is 45 dBA (quieter than 69.1% of Hybrid/Electric Heat Pump models).

State electric sensitivity for State HPVX-66-DHPT 2**: 10-year operating spend spans $2,268 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $7,313 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Competing options beside State HPVX-66-DHPT 2** (3.2 UEF) are A. O. Smith HPTV-66 2** (3.2 UEF, at parity) and American HPV10266H009DV 2** (3.2 UEF, at parity).

Where Does State HPVX-66-DHPT 2** Rank Against Peer Hybrid/Electric Heat Pump Units?

Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, State HPVX-66-DHPT 2** holds #646 of 706; inspect footprint, circuit load, and efficiency deltas here.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandState81 certified listingsENERGY STAR PD 2546249
Model NumberHPVX-66-DHPT 2**Draw pattern: High-UsageHPVX-66-DHPT 2**
Uniform Energy Factor (UEF)3.2-0.50 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)76 gal+4 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,550 kWh/yr+478 kWh/yr vs. 1,072 kWh/yr medianEst. $281/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency368%-61.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)61" H x 23" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" D)Doorway & ceiling check
Electrical Circuit Requirements120 V / 15 A max120V plug-in retrofit circuit; slower heat-pump-only recoveryNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-513A (GWP:630)Lower-GWP refrigerant alignment (EPA AIM Act)EPA AIM Act Compliance
Sound Pressure Level45 dBAtop 30.9% · quieter than 69.1% of Hybrid/Electric Heat Pump models · -4 dBA vs. 49 dBA medianIndoor placement check
Certification Date2025-12-12Certified 2025-12-12Markets: United States

How Much Electricity Does HPVX-66-DHPT 2** Use in Different States?

Estimated at $281/yr nationally (1,550 kWh/yr), 10-year utility spending for State HPVX-66-DHPT 2** shifts sharply between low-rate hydro and coastal grids.

Estimated Annual Electricity Cost by State Rate (1,550 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$281.00/yrHawaii$731.00/yrCalifornia$461.00/yrTexas$247.00/yrWashington$227.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $281/yr $2,815 $6,975
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $731/yr $7,313 $18,122
California 29.75 ¢/kWh ($0.2975) $461/yr $4,611 $11,427
Texas 15.91 ¢/kWh ($0.1591) $247/yr $2,466 $6,111
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $227/yr $2,268 $5,619
Estimated electricity spend (1,550 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Does CPSC Flag Any Safety Notices on State Units?

Checking 2026-11-23 SaferProducts data shows 4 notices mentioning State; always cross-reference affected serial prefixes before ordering components. See Serial Number Lookup.

4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #08241 (2008-04-03): A.O. Smith Recalls Gas Water Heaters Due to Fire and Carbon Monoxide Hazards (CPSC Notice)
  • Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
  • Recall #04128 (2004-04-28): CPSC, White-Rodgers Announce Recall of LP and Convertible Gas Water Heater Temperature Controls (CPSC Notice)

Which Competing Hybrid/Electric Heat Pump Models Compare Closest to HPVX-66-DHPT 2**?

Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to State HPVX-66-DHPT 2**'s gallon capacity and 3.2 UEF efficiency.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith HPTV-66 2** Hybrid/Electric Heat Pump 68 gal 76 gal 3.2 (at parity) 1,550
American HPV10266H009DV 2** Hybrid/Electric Heat Pump 68 gal 76 gal 3.2 (at parity) 1,550
Lochinvar HPV065KD 2** Hybrid/Electric Heat Pump 68 gal 76 gal 3.2 (at parity) 1,550
RELIANCE WATER HEATERS 10-66-DHPTV 2** Hybrid/Electric Heat Pump 68 gal 76 gal 3.2 (at parity) 1,550
A. O. Smith HPV10-66H01DV 2** Hybrid/Electric Heat Pump 68 gal 76 gal 3.2 (at parity) 1,550

Which Home Setups Are NOT a Fit for State HPVX-66-DHPT 2**?

Comparing State HPVX-66-DHPT 2** against A. O. Smith HPTV-66 2** requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

Key Limitations & Exclusions

  • State HPVX-66-DHPT 2** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 45 dBA; avoid mounting State HPVX-66-DHPT 2** directly beside quiet bedrooms.
  • Requires condensate drain routing and 120V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing State HPVX-66-DHPT 2** Strong Fit — 3.2 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare A. O. Smith HPTV-66 2** footprint.

Common Homeowner Questions for State HPVX-66-DHPT 2**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does State HPVX-66-DHPT 2** score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; State HPVX-66-DHPT 2** logs 3.2 UEF (Pass: +0.70 / +28.0%) within the 706-unit Hybrid/Electric Heat Pump group.

What physical clearance dimensions apply when installing State HPVX-66-DHPT 2**?

With a 61 in. height and 23 in. diameter, State HPVX-66-DHPT 2** fits spaces matching: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" d), plus 6–12 in. above for plumbing shutoffs.

What 240V circuit or IFGC fuel line capacity fits State HPVX-66-DHPT 2**?

Powered via 120V at 15A max, State HPVX-66-DHPT 2** requires: 120V plug-in retrofit circuit; slower heat-pump-only recovery. Confirm double-pole breaker sizing and condensate pump outlet proximity.

How do state electricity prices change annual costs for State HPVX-66-DHPT 2**?

Annual electric spend for State HPVX-66-DHPT 2** (1,550 kWh/yr) averages $281/yr nationwide (ranging from $227/yr in Washington hydro tiers up to $731/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.

What homeowner setups should avoid choosing State HPVX-66-DHPT 2**?

Homes lacking a condensate drain or 120V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on State HPVX-66-DHPT 2**.

Is State HPVX-66-DHPT 2** sized adequately for a 2-to-4-person household?

ENERGY STAR certifies State HPVX-66-DHPT 2** at 76 gal First Hour Rating (+4 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.

Does State have active CPSC SaferProducts notices affecting HPVX-66-DHPT 2**?

CPSC SaferProducts records show 4 brand-level recall notices mentioning State as of 2026-11-23, including #19029 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

Which competing water heater matches State HPVX-66-DHPT 2** (3.2 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for State HPVX-66-DHPT 2**. Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPTV-66 2** (3.2 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks