Skip to main content
ENERGY STAR water heater model · PD 3417702

American HPA10266H045DV 2** Water Heater Specifications (3.84 UEF)

Engineered as a Electric Hybrid/Electric Heat Pump unit, American HPA10266H045DV 2** achieves a certified 3.84 UEF rating across its 68-gallon nominal tank, 83 gal First Hour Rating and ranks #221 of 706 in its 706-model cohort (PD 3417702), recording Pass: +1.34 / +53.6% under 2029 DOE rules. Rated annual electricity draw of 1,292 kWh/yr equates to roughly $235/yr ($2,346 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith CAHP-66 2** (3.84 UEF).

Uniform Energy Factor
3.84 UEF
Cohort UEF Rank
#221 of 706 (top 32.4%)
First Hour Rating
83 gal
Storage Volume
68 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.34 / +53.6%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking American HPA10266H045DV 2** at 3.84 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50American HPA10266H045DV 2**: 3.84
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows American HPA10266H045DV 2** relative to the cohort median.
Efficiency comparison & rule summary

Within the 706-unit Hybrid/Electric Heat Pump cohort, American HPA10266H045DV 2** logs 3.84 UEF and ranks #221 of 706.

Against 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF), American HPA10266H045DV 2** holds a +1.34 UEF (+53.6%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 1,292 kWh/yr for American HPA10266H045DV 2** runs ~$235/yr vs. ~$979/yr for a 0.92 UEF electric tank.

State electric sensitivity for American HPA10266H045DV 2**: 10-year operating spend spans $1,890 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,096 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Cross-shopping American HPA10266H045DV 2** (3.84 UEF)? Check A. O. Smith CAHP-66 2** (3.84 UEF, at parity) and Lochinvar CHPA-66 2** (3.84 UEF, at parity).

What Physical and Thermal Ratings Define American HPA10266H045DV 2**?

Positioning at #221 of 706 (top 32.4%) out of 706 Hybrid/Electric Heat Pump peers, American HPA10266H045DV 2** pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandAmerican79 certified listingsENERGY STAR PD 3417702
Model NumberHPA10266H045DV 2**Draw pattern: High-UsageHPA10266H045DV 2**
Uniform Energy Factor (UEF)3.84+0.14 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)83 gal+11 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,292 kWh/yr+220 kWh/yr vs. 1,072 kWh/yr medianEst. $235/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency435%+6.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)61" H x 23" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 22 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2025-12-12Certified 2025-12-12Markets: United States

Why Do State Utility Rates Shift HPA10266H045DV 2** Running Costs?

Consuming 1,292 kWh annually puts American HPA10266H045DV 2** near $235/yr at US baseline tariffs, with multi-state EIA comparisons charted below.

Estimated Annual Electricity Cost by State Rate (1,292 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$235.00/yrHawaii$610.00/yrCalifornia$384.00/yrTexas$206.00/yrWashington$189.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $235/yr $2,346 $7,447
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $610/yr $6,096 $19,349
California 29.75 ¢/kWh ($0.2975) $384/yr $3,844 $12,200
Texas 15.91 ¢/kWh ($0.1591) $206/yr $2,056 $6,525
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $189/yr $1,890 $6,000
Estimated electricity spend (1,292 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Have Any American Series Triggered CPSC Recalls?

SaferProducts records retrieved 2026-11-23 list 2 brand notices under American; inspect model coverage dates prior to valve or anode service. See Serial Number Lookup.

2 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #16171 (2016-05-24): Water Heating Technologies Recalls Gas Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)

What Are 5 Direct Alternatives to American HPA10266H045DV 2**?

Homeowners cross-shopping American HPA10266H045DV 2** frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith CAHP-66 2** Hybrid/Electric Heat Pump 68 gal 83 gal 3.84 (at parity) 1,292
Lochinvar CHPA-66 2** Hybrid/Electric Heat Pump 68 gal 83 gal 3.84 (at parity) 1,292
RELIANCE WATER HEATERS 10-66-DHPTA 2** Hybrid/Electric Heat Pump 68 gal 83 gal 3.84 (at parity) 1,292
State CSHP-66 2** Hybrid/Electric Heat Pump 68 gal 83 gal 3.84 (at parity) 1,292
A. O. Smith HPA10-66H45DV 2** Hybrid/Electric Heat Pump 68 gal 83 gal 3.84 (at parity) 1,292

What Are the Limitations of American HPA10266H045DV 2** and Who Should Not Install It?

Before ordering American HPA10266H045DV 2** (Hybrid/Electric Heat Pump, 3.84 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.

Key Limitations & Exclusions

  • American HPA10266H045DV 2** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting American HPA10266H045DV 2** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing American HPA10266H045DV 2** Strong Fit — 3.84 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare A. O. Smith CAHP-66 2** footprint.

Sizing, Efficiency & Recall Answers for American HPA10266H045DV 2**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Does American HPA10266H045DV 2** pass the May 6, 2029 federal DOE efficiency rule?

American HPA10266H045DV 2** carries a verified 3.84 UEF rating (Pass: +1.34 / +53.6%), ranking #221 of 706 (top 32.4%) across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.

What doorway width and ceiling height does American HPA10266H045DV 2** need?

American HPA10266H045DV 2** stands 61 in. high with a 23 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.

What gas pipe size or electrical breaker does American HPA10266H045DV 2** require?

American HPA10266H045DV 2** uses a 240V branch circuit at 22A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.

How much electricity or energy does American HPA10266H045DV 2** cost per year to run?

Rated at 1,292 kWh/yr, American HPA10266H045DV 2** costs about $235/yr ($2,350 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $189/yr in Washington hydro tiers up to $610/yr in Hawaii).

Who should NOT install American HPA10266H045DV 2**, and what are its limits?

American HPA10266H045DV 2** (3.84 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.

How many bathrooms or people can American HPA10266H045DV 2** serve at peak demand?

American HPA10266H045DV 2** achieves a 83 gal First Hour Rating (+11 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.

Are there CPSC safety recalls or serial checks for American HPA10266H045DV 2**?

CPSC SaferProducts records show 2 brand-level recall notices mentioning American as of 2026-11-23, including #16171 (2016-05-24). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

What 2026 rebates apply to American HPA10266H045DV 2**, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is A. O. Smith CAHP-66 2** (3.84 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks