Skip to main content
ENERGY STAR water heater model · PD 2546248

A. O. Smith HPV10-66H01DV 2** Water Heater Specifications (3.2 UEF)

With PD 2546248 certification, A. O. Smith HPV10-66H01DV 2** (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.2 UEF rating across its 68-gallon nominal tank, 76 gal First Hour Rating, standing #646 of 706 across 706 peers with Pass: +0.70 / +28.0% for May 6, 2029. Rated annual electricity draw of 1,550 kWh/yr equates to roughly $281/yr ($2,815 over 10 years) at 18.16 cents/kWh. Closest certified alternative is American HPV10266H009DV 2** (3.2 UEF).

Uniform Energy Factor
3.2 UEF
Cohort UEF Rank
#646 of 706
First Hour Rating
76 gal
Storage Volume
68 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +0.70 / +28.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking A. O. Smith HPV10-66H01DV 2** at 3.2 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50A. O. Smith HPV10-66H01DV 2**: 3.20
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows A. O. Smith HPV10-66H01DV 2** relative to the cohort median.
Efficiency comparison & rule summary

ENERGY STAR certification places A. O. Smith HPV10-66H01DV 2** at 3.2 UEF (#646 of 706; -0.50 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.

May 6, 2029 readiness: A. O. Smith HPV10-66H01DV 2** stands +0.70 UEF (+28.0%) relative to 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,550 kWh/yr for A. O. Smith HPV10-66H01DV 2** runs ~$281/yr vs. ~$979/yr for a 0.92 UEF electric tank. Acoustic output is 45 dBA (quieter than 69.1% of Hybrid/Electric Heat Pump models).

State electric sensitivity for A. O. Smith HPV10-66H01DV 2**: 10-year operating spend spans $2,268 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $7,313 in Hawaii (Highest EIA State) (47.18 cents/kWh).

In the Hybrid/Electric Heat Pump tier, American HPV10266H009DV 2** (3.2 UEF, at parity) and Lochinvar HPV065KD 2** (3.2 UEF, at parity) bracket A. O. Smith HPV10-66H01DV 2**.

How Complete Are the Certified Metrics for A. O. Smith HPV10-66H01DV 2**?

Standing at #646 of 706 among 706 certified Hybrid/Electric Heat Pump heaters, A. O. Smith HPV10-66H01DV 2** brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandA. O. Smith144 certified listingsENERGY STAR PD 2546248
Model NumberHPV10-66H01DV 2**Draw pattern: High-UsageHPV10-66H01DV 2**
Uniform Energy Factor (UEF)3.2-0.50 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)76 gal+4 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,550 kWh/yr+478 kWh/yr vs. 1,072 kWh/yr medianEst. $281/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency368%-61.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)61" H x 23" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" D)Doorway & ceiling check
Electrical Circuit Requirements120 V / 15 A max120V plug-in retrofit circuit; slower heat-pump-only recoveryNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-513A (GWP:630)Lower-GWP refrigerant alignment (EPA AIM Act)EPA AIM Act Compliance
Sound Pressure Level45 dBAtop 30.9% · quieter than 69.1% of Hybrid/Electric Heat Pump models · -4 dBA vs. 49 dBA medianIndoor placement check
Certification Date2025-12-12Certified 2025-12-12Markets: United States

What Is the Projected Utility Bill for HPV10-66H01DV 2** by State?

At 1,550 kWh/yr, A. O. Smith HPV10-66H01DV 2** averages about $281/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.

Estimated Annual Electricity Cost by State Rate (1,550 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$281.00/yrHawaii$731.00/yrCalifornia$461.00/yrTexas$247.00/yrWashington$227.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $281/yr $2,815 $6,975
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $731/yr $7,313 $18,122
California 29.75 ¢/kWh ($0.2975) $461/yr $4,611 $11,427
Texas 15.91 ¢/kWh ($0.1591) $247/yr $2,466 $6,111
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $227/yr $2,268 $5,619
Estimated electricity spend (1,550 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are A. O. Smith Models Affected by Current CPSC Notices?

Review 4 brand-matched CPSC entries pulled 2026-11-23 for A. O. Smith and confirm your serial tag before scheduling contractor service. See Serial Number Lookup.

4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #19030 (2018-11-08): A. O. Smith Recalls 30-Gallon Gas Water Heaters Due to Fire Hazard; Sold Exclusively at Lowe's (CPSC Notice)
  • Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
  • Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)

Which 5 Models Offer Similar Output to HPV10-66H01DV 2**?

Ordered by minimal capacity and UEF spread relative to A. O. Smith HPV10-66H01DV 2**, these five certified peers give direct replacement benchmarks.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
American HPV10266H009DV 2** Hybrid/Electric Heat Pump 68 gal 76 gal 3.2 (at parity) 1,550
Lochinvar HPV065KD 2** Hybrid/Electric Heat Pump 68 gal 76 gal 3.2 (at parity) 1,550
RELIANCE WATER HEATERS 10-66-DHPTV 2** Hybrid/Electric Heat Pump 68 gal 76 gal 3.2 (at parity) 1,550
State HPVX-66-DHPT 2** Hybrid/Electric Heat Pump 68 gal 76 gal 3.2 (at parity) 1,550
American HPA10266H045DV 2** Hybrid/Electric Heat Pump 68 gal 83 gal 3.84 (+0.64) 1,292

Which Home Setups Are NOT a Fit for A. O. Smith HPV10-66H01DV 2**?

Comparing A. O. Smith HPV10-66H01DV 2** against American HPV10266H009DV 2** requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

Key Limitations & Exclusions

  • A. O. Smith HPV10-66H01DV 2** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 45 dBA; avoid mounting A. O. Smith HPV10-66H01DV 2** directly beside quiet bedrooms.
  • Requires condensate drain routing and 120V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing A. O. Smith HPV10-66H01DV 2** Strong Fit — 3.2 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare American HPV10266H009DV 2** footprint.

Practical Specs & Code Questions for A. O. Smith HPV10-66H01DV 2**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does A. O. Smith HPV10-66H01DV 2** score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; A. O. Smith HPV10-66H01DV 2** logs 3.2 UEF (Pass: +0.70 / +28.0%) within the 706-unit Hybrid/Electric Heat Pump group.

What physical clearance dimensions apply when installing A. O. Smith HPV10-66H01DV 2**?

With a 61 in. height and 23 in. diameter, A. O. Smith HPV10-66H01DV 2** fits spaces matching: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" d), plus 6–12 in. above for plumbing shutoffs.

What 240V circuit or IFGC fuel line capacity fits A. O. Smith HPV10-66H01DV 2**?

Powered via 120V at 15A max, A. O. Smith HPV10-66H01DV 2** requires: 120V plug-in retrofit circuit; slower heat-pump-only recovery. Confirm double-pole breaker sizing and condensate pump outlet proximity.

How do state electricity prices change annual costs for A. O. Smith HPV10-66H01DV 2**?

Annual electric spend for A. O. Smith HPV10-66H01DV 2** (1,550 kWh/yr) averages $281/yr nationwide (ranging from $227/yr in Washington hydro tiers up to $731/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.

What homeowner setups should avoid choosing A. O. Smith HPV10-66H01DV 2**?

Homes lacking a condensate drain or 120V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on A. O. Smith HPV10-66H01DV 2**.

Is A. O. Smith HPV10-66H01DV 2** sized adequately for a 2-to-4-person household?

ENERGY STAR certifies A. O. Smith HPV10-66H01DV 2** at 76 gal First Hour Rating (+4 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.

Does A. O. Smith have active CPSC SaferProducts notices affecting HPV10-66H01DV 2**?

CPSC SaferProducts records show 4 brand-level recall notices mentioning A. O. Smith as of 2026-11-23, including #19030 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

Which competing water heater matches A. O. Smith HPV10-66H01DV 2** (3.2 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for A. O. Smith HPV10-66H01DV 2**. Closest peer in Hybrid/Electric Heat Pump is American HPV10266H009DV 2** (3.2 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks