AMERICAN STANDARD WATER HEATERS ASHPWH-40***** Water Heater Specifications (3.58 UEF)
Engineered as a Electric Hybrid/Electric Heat Pump unit, AMERICAN STANDARD WATER HEATERS ASHPWH-40***** achieves a certified 3.58 UEF rating across its 37-gallon nominal tank, 66 gal First Hour Rating and ranks #412 of 706 in its 706-model cohort (PD 2853327), recording Pass: +1.28 / +55.7% under 2029 DOE rules. Rated annual electricity draw of 907 kWh/yr equates to roughly $165/yr ($1,647 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Ariston ARIHPWH-40 (3.58 UEF).
- Uniform Energy Factor
- 3.58 UEF
- Cohort UEF Rank
- #412 of 706
- First Hour Rating
- 66 gal
- Storage Volume
- 37 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.28 / +55.7%

Within the 706-unit Hybrid/Electric Heat Pump cohort, AMERICAN STANDARD WATER HEATERS ASHPWH-40***** logs 3.58 UEF and ranks #412 of 706.
Against 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF), AMERICAN STANDARD WATER HEATERS ASHPWH-40***** holds a +1.28 UEF (+55.7%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 907 kWh/yr for AMERICAN STANDARD WATER HEATERS ASHPWH-40***** runs ~$165/yr vs. ~$641/yr for a 0.92 UEF electric tank.
State electric sensitivity for AMERICAN STANDARD WATER HEATERS ASHPWH-40*****: 10-year operating spend spans $1,327 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,279 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Cross-shopping AMERICAN STANDARD WATER HEATERS ASHPWH-40***** (3.58 UEF)? Check Ariston ARIHPWH-40 (3.58 UEF, at parity) and Lennox WHHP040T45MD240S**** (3.55 UEF, delta -0.03).
How Do AMERICAN STANDARD WATER HEATERS ASHPWH-40***** Specs Compare to Hybrid/Electric Heat Pump Medians?
AMERICAN STANDARD WATER HEATERS ASHPWH-40***** places #412 of 706 across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | AMERICAN STANDARD WATER HEATERS | 4 certified listings | ENERGY STAR PD 2853327 |
| Model Number | ASHPWH-40***** | Draw pattern: Medium-Usage | ASHPWH-40***** |
| Uniform Energy Factor (UEF) | 3.58 | -0.12 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 66 gal | -6 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 907 kWh/yr | -165 kWh/yr vs. 1,072 kWh/yr median | Est. $165/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 402% | -27.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 37.6" H x 18.2" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.2" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-02-10 | Certified 2026-02-10 | Markets: United States, Canada |
What Does ASHPWH-40***** Cost to Operate Across State Electricity Rates?
At 907 kWh/yr, AMERICAN STANDARD WATER HEATERS ASHPWH-40***** runs roughly $165/yr on the EIA national average tier under August 2026 Table 5.6.A rates.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $165/yr | $1,647 | $4,762 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $428/yr | $4,279 | $12,371 |
| California | 29.75 ¢/kWh ($0.2975) | $270/yr | $2,698 | $7,800 |
| Texas | 15.91 ¢/kWh ($0.1591) | $144/yr | $1,443 | $4,172 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $133/yr | $1,327 | $3,836 |
Are There Active CPSC Safety Recalls for AMERICAN STANDARD WATER HEATERS Water Heaters?
Our 2026-11-23 CPSC SaferProducts query surfaced 2 brand-level recall notices associated with AMERICAN STANDARD WATER HEATERS; match your serial plate before repair. See Serial Number Lookup.
- Recall #16171 (2016-05-24): Water Heating Technologies Recalls Gas Water Heaters Due to Fire Hazard (CPSC Notice)
- Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)
Which Certified Water Heaters Match ASHPWH-40***** Most Closely?
These 5 competing Hybrid/Electric Heat Pump units sit nearest to AMERICAN STANDARD WATER HEATERS ASHPWH-40***** by storage capacity and 3.58 UEF rating.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Ariston ARIHPWH-40 | Hybrid/Electric Heat Pump | 37 gal | 66 gal | 3.58 (at parity) | 907 |
| Lennox WHHP040T45MD240S**** | Hybrid/Electric Heat Pump | 37 gal | 65 gal | 3.55 (-0.03) | 915 |
| A. O. Smith CAHP-40 2** | Hybrid/Electric Heat Pump | 36 gal | 55 gal | 3.6 (+0.02) | 902 |
| American HPA10240H045DV 2** | Hybrid/Electric Heat Pump | 36 gal | 55 gal | 3.6 (+0.02) | 902 |
| Ariston ARIHPWH-40-T | Hybrid/Electric Heat Pump | 37 gal | 65 gal | 3.55 (-0.03) | 915 |
What Are the Limitations of AMERICAN STANDARD WATER HEATERS ASHPWH-40***** and Who Should Not Install It?
Before ordering AMERICAN STANDARD WATER HEATERS ASHPWH-40***** (Hybrid/Electric Heat Pump, 3.58 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.
Key Limitations & Exclusions
- AMERICAN STANDARD WATER HEATERS ASHPWH-40***** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting AMERICAN STANDARD WATER HEATERS ASHPWH-40***** directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
What Are the Key Questions About AMERICAN STANDARD WATER HEATERS ASHPWH-40*****?
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Does AMERICAN STANDARD WATER HEATERS ASHPWH-40***** pass the May 6, 2029 federal DOE efficiency rule?
AMERICAN STANDARD WATER HEATERS ASHPWH-40***** carries a verified 3.58 UEF rating (Pass: +1.28 / +55.7%), ranking #412 of 706 across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.
What doorway width and ceiling height does AMERICAN STANDARD WATER HEATERS ASHPWH-40***** need?
AMERICAN STANDARD WATER HEATERS ASHPWH-40***** stands 37.6 in. high with a 18.2 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.2" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.
What gas pipe size or electrical breaker does AMERICAN STANDARD WATER HEATERS ASHPWH-40***** require?
AMERICAN STANDARD WATER HEATERS ASHPWH-40***** uses a 240V branch circuit at 21A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.
How much electricity or energy does AMERICAN STANDARD WATER HEATERS ASHPWH-40***** cost per year to run?
Rated at 907 kWh/yr, AMERICAN STANDARD WATER HEATERS ASHPWH-40***** costs about $165/yr ($1,650 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $133/yr in Washington hydro tiers up to $428/yr in Hawaii).
Who should NOT install AMERICAN STANDARD WATER HEATERS ASHPWH-40*****, and what are its limits?
AMERICAN STANDARD WATER HEATERS ASHPWH-40***** (3.58 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.
How many bathrooms or people can AMERICAN STANDARD WATER HEATERS ASHPWH-40***** serve at peak demand?
AMERICAN STANDARD WATER HEATERS ASHPWH-40***** achieves a 66 gal First Hour Rating (-6 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.
Are there CPSC safety recalls or serial checks for AMERICAN STANDARD WATER HEATERS ASHPWH-40*****?
CPSC SaferProducts records show 2 brand-level recall notices mentioning AMERICAN STANDARD WATER HEATERS as of 2026-11-23, including #16171 (2016-05-24). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
What 2026 rebates apply to AMERICAN STANDARD WATER HEATERS ASHPWH-40*****, and what peer compares closest?
Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is Ariston ARIHPWH-40 (3.58 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)