Ariston ARIHPWH-40-T Water Heater Specifications (3.55 UEF)
The Ariston ARIHPWH-40-T (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.55 UEF rating across its 37-gallon nominal tank, 65 gal First Hour Rating, ranking #414 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 4518065). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +1.25 / +54.3%. Rated annual electricity draw of 915 kWh/yr equates to roughly $166/yr ($1,662 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Lennox WHHP040T45MD240S**** (3.55 UEF).
- Uniform Energy Factor
- 3.55 UEF
- Cohort UEF Rank
- #414 of 706
- First Hour Rating
- 65 gal
- Storage Volume
- 37 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.25 / +54.3%

Ariston ARIHPWH-40-T (3.55 UEF) ranks #414 of 706 Hybrid/Electric Heat Pump models — 26-way tie; more efficient than 37.8% of Hybrid/Electric Heat Pump models, -0.15 UEF below the 3.70 UEF median.
Federal 2029 margin for Ariston ARIHPWH-40-T: +1.25 UEF (+54.3%) vs. 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 915 kWh/yr for Ariston ARIHPWH-40-T runs ~$166/yr vs. ~$641/yr for a 0.92 UEF electric tank.
State electric sensitivity for Ariston ARIHPWH-40-T: 10-year operating spend spans $1,339 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,317 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Peer comparison: Ariston ARIHPWH-40-T (3.55 UEF) compares closely with Lennox WHHP040T45MD240S**** (3.55 UEF, at parity) and AMERICAN STANDARD WATER HEATERS ASHPWH-40***** (3.58 UEF, delta +0.03).
What Physical and Thermal Ratings Define Ariston ARIHPWH-40-T?
Positioning at #414 of 706 out of 706 Hybrid/Electric Heat Pump peers, Ariston ARIHPWH-40-T pairs measured UEF performance with specific clearance and wiring rules.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Ariston | 8 certified listings | ENERGY STAR PD 4518065 |
| Model Number | ARIHPWH-40-T | Draw pattern: Medium-Usage | ARIHPWH-40-T |
| Uniform Energy Factor (UEF) | 3.55 | -0.15 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 65 gal | -7 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 915 kWh/yr | -157 kWh/yr vs. 1,072 kWh/yr median | Est. $166/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 407% | -22.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 37.8" H x 18.2" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.2" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-513A (GWP:630) | Lower-GWP refrigerant alignment (EPA AIM Act) | EPA AIM Act Compliance |
| Certification Date | 2026-02-10 | Certified 2026-02-10 | Markets: United States, Canada |
Why Do State Utility Rates Shift ARIHPWH-40-T Running Costs?
Consuming 915 kWh annually puts Ariston ARIHPWH-40-T near $166/yr at US baseline tariffs, with multi-state EIA comparisons charted below.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $166/yr | $1,662 | $4,751 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $432/yr | $4,317 | $12,342 |
| California | 29.75 ¢/kWh ($0.2975) | $272/yr | $2,722 | $7,783 |
| Texas | 15.91 ¢/kWh ($0.1591) | $146/yr | $1,456 | $4,162 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $134/yr | $1,339 | $3,827 |
Have Any Ariston Series Triggered CPSC Recalls?
SaferProducts screening on 2026-11-23 returned zero recall matches for Ariston; confirm tank age separately using the rating-plate serial pattern. See Serial Number Lookup.
What Are 5 Direct Alternatives to Ariston ARIHPWH-40-T?
Homeowners cross-shopping Ariston ARIHPWH-40-T frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Lennox WHHP040T45MD240S**** | Hybrid/Electric Heat Pump | 37 gal | 65 gal | 3.55 (at parity) | 915 |
| AMERICAN STANDARD WATER HEATERS ASHPWH-40***** | Hybrid/Electric Heat Pump | 37 gal | 66 gal | 3.58 (+0.03) | 907 |
| Friedrich PROH40 T2 FD310BM | Hybrid/Electric Heat Pump | 36 gal | 60 gal | 3.5 (-0.05) | 879 |
| Rheem CPROPH40 T2 RH350BM | Hybrid/Electric Heat Pump | 36 gal | 60 gal | 3.5 (-0.05) | 879 |
| Friedrich PROH40 T2 FD310UM | Hybrid/Electric Heat Pump | 36 gal | 60 gal | 3.5 (-0.05) | 879 |
Which Home Setups Are NOT a Fit for Ariston ARIHPWH-40-T?
Comparing Ariston ARIHPWH-40-T against Lennox WHHP040T45MD240S**** requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.
Key Limitations & Exclusions
- Ariston ARIHPWH-40-T needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Ariston ARIHPWH-40-T directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Sizing, Efficiency & Recall Answers for Ariston ARIHPWH-40-T
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
How does Ariston ARIHPWH-40-T score under 10 CFR 430.32 May 2029 water heater minimums?
Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; Ariston ARIHPWH-40-T logs 3.55 UEF (Pass: +1.25 / +54.3%) within the 706-unit Hybrid/Electric Heat Pump group.
What physical clearance dimensions apply when installing Ariston ARIHPWH-40-T?
With a 37.8 in. height and 18.2 in. diameter, Ariston ARIHPWH-40-T fits spaces matching: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.2" d), plus 6–12 in. above for plumbing shutoffs.
What 240V circuit or IFGC fuel line capacity fits Ariston ARIHPWH-40-T?
Powered via 240V at 21A max, Ariston ARIHPWH-40-T requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.
How do state electricity prices change annual costs for Ariston ARIHPWH-40-T?
Annual electric spend for Ariston ARIHPWH-40-T (915 kWh/yr) averages $166/yr nationwide (ranging from $134/yr in Washington hydro tiers up to $432/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.
What homeowner setups should avoid choosing Ariston ARIHPWH-40-T?
Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on Ariston ARIHPWH-40-T.
Is Ariston ARIHPWH-40-T sized adequately for a 2-to-4-person household?
ENERGY STAR certifies Ariston ARIHPWH-40-T at 65 gal First Hour Rating (-7 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.
Does Ariston have active CPSC SaferProducts notices affecting ARIHPWH-40-T?
Zero CPSC recall alerts matched Ariston (2026-11-23 check). Keep your Ariston ARIHPWH-40-T serial code handy to track standard 6-to-12-year OEM warranty coverage.
Which competing water heater matches Ariston ARIHPWH-40-T (3.55 UEF) most closely?
State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for Ariston ARIHPWH-40-T. Closest peer in Hybrid/Electric Heat Pump is Lennox WHHP040T45MD240S**** (3.55 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)