Skip to main content
ENERGY STAR water heater model · PD 4529480

Lennox WHHP040T45MD240S**** Water Heater Specifications (3.55 UEF)

The Lennox WHHP040T45MD240S**** (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.55 UEF rating across its 37-gallon nominal tank, 65 gal First Hour Rating, ranking #414 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 4529480). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +1.25 / +54.3%. Rated annual electricity draw of 915 kWh/yr equates to roughly $166/yr ($1,662 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Ariston ARIHPWH-40-T (3.55 UEF).

Uniform Energy Factor
3.55 UEF
Cohort UEF Rank
#414 of 706
First Hour Rating
65 gal
Storage Volume
37 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.25 / +54.3%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Lennox WHHP040T45MD240S**** at 3.55 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30Lennox WHHP040T45MD240S****: 3.55
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Lennox WHHP040T45MD240S**** relative to the cohort median.
Efficiency comparison & rule summary

Lennox WHHP040T45MD240S**** (3.55 UEF) ranks #414 of 706 Hybrid/Electric Heat Pump models — 26-way tie; more efficient than 37.8% of Hybrid/Electric Heat Pump models, -0.15 UEF below the 3.70 UEF median.

Federal 2029 margin for Lennox WHHP040T45MD240S****: +1.25 UEF (+54.3%) vs. 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 915 kWh/yr for Lennox WHHP040T45MD240S**** runs ~$166/yr vs. ~$641/yr for a 0.92 UEF electric tank.

State electric sensitivity for Lennox WHHP040T45MD240S****: 10-year operating spend spans $1,339 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,317 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Peer comparison: Lennox WHHP040T45MD240S**** (3.55 UEF) compares closely with Ariston ARIHPWH-40-T (3.55 UEF, at parity) and AMERICAN STANDARD WATER HEATERS ASHPWH-40***** (3.58 UEF, delta +0.03).

Which Specs Set Lennox WHHP040T45MD240S**** Apart From Cohort Averages?

Ranked #414 of 706 inside the 706-model Hybrid/Electric Heat Pump cohort, Lennox WHHP040T45MD240S**** is evaluated row by row below against category medians.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandLennox4 certified listingsENERGY STAR PD 4529480
Model NumberWHHP040T45MD240S****Draw pattern: Medium-UsageWHHP040T45MD240S****
Uniform Energy Factor (UEF)3.55-0.15 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)65 gal-7 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use915 kWh/yr-157 kWh/yr vs. 1,072 kWh/yr medianEst. $166/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency407%-22.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)37.8" H x 18.2" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.2" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 21 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-513A (GWP:630)Lower-GWP refrigerant alignment (EPA AIM Act)EPA AIM Act Compliance
Certification Date2026-02-25Certified 2026-02-25Markets: United States, Canada

How Do Regional kWh Prices Impact WHHP040T45MD240S**** Over 10 Years?

Using EIA Table 5.6.A benchmarks, Lennox WHHP040T45MD240S****'s 915 kWh/yr draw translates to roughly $166/yr on typical US residential bills.

Estimated Annual Electricity Cost by State Rate (915 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$166.00/yrHawaii$432.00/yrCalifornia$272.00/yrTexas$146.00/yrWashington$134.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $166/yr $1,662 $4,751
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $432/yr $4,317 $12,342
California 29.75 ¢/kWh ($0.2975) $272/yr $2,722 $7,783
Texas 15.91 ¢/kWh ($0.1591) $146/yr $1,456 $4,162
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $134/yr $1,339 $3,827
Estimated electricity spend (915 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

What Should Lennox Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC recall sweep recorded zero brand matches for Lennox; run a quick serial-number check to verify age before replacing wear parts. See Serial Number Lookup.

How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?

Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Ariston ARIHPWH-40-T Hybrid/Electric Heat Pump 37 gal 65 gal 3.55 (at parity) 915
AMERICAN STANDARD WATER HEATERS ASHPWH-40***** Hybrid/Electric Heat Pump 37 gal 66 gal 3.58 (+0.03) 907
Friedrich PROH40 T2 FD310BM Hybrid/Electric Heat Pump 36 gal 60 gal 3.5 (-0.05) 879
Rheem CPROPH40 T2 RH350BM Hybrid/Electric Heat Pump 36 gal 60 gal 3.5 (-0.05) 879
Ariston ARIHPWH-40 Hybrid/Electric Heat Pump 37 gal 66 gal 3.58 (+0.03) 907

Which Home Setups Are NOT a Fit for Lennox WHHP040T45MD240S****?

Comparing Lennox WHHP040T45MD240S**** against Ariston ARIHPWH-40-T requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

Key Limitations & Exclusions

  • Lennox WHHP040T45MD240S**** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Lennox WHHP040T45MD240S**** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Lennox WHHP040T45MD240S**** Strong Fit — 3.55 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Ariston ARIHPWH-40-T footprint.

Frequently Asked Technical Questions: Lennox WHHP040T45MD240S****

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does Lennox WHHP040T45MD240S**** score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; Lennox WHHP040T45MD240S**** logs 3.55 UEF (Pass: +1.25 / +54.3%) within the 706-unit Hybrid/Electric Heat Pump group.

What physical clearance dimensions apply when installing Lennox WHHP040T45MD240S****?

With a 37.8 in. height and 18.2 in. diameter, Lennox WHHP040T45MD240S**** fits spaces matching: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.2" d), plus 6–12 in. above for plumbing shutoffs.

What 240V circuit or IFGC fuel line capacity fits Lennox WHHP040T45MD240S****?

Powered via 240V at 21A max, Lennox WHHP040T45MD240S**** requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.

How do state electricity prices change annual costs for Lennox WHHP040T45MD240S****?

Annual electric spend for Lennox WHHP040T45MD240S**** (915 kWh/yr) averages $166/yr nationwide (ranging from $134/yr in Washington hydro tiers up to $432/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.

What homeowner setups should avoid choosing Lennox WHHP040T45MD240S****?

Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on Lennox WHHP040T45MD240S****.

Is Lennox WHHP040T45MD240S**** sized adequately for a 2-to-4-person household?

ENERGY STAR certifies Lennox WHHP040T45MD240S**** at 65 gal First Hour Rating (-7 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.

Does Lennox have active CPSC SaferProducts notices affecting WHHP040T45MD240S****?

Zero CPSC recall alerts matched Lennox (2026-11-23 check). Keep your Lennox WHHP040T45MD240S**** serial code handy to track standard 6-to-12-year OEM warranty coverage.

Which competing water heater matches Lennox WHHP040T45MD240S**** (3.55 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for Lennox WHHP040T45MD240S****. Closest peer in Hybrid/Electric Heat Pump is Ariston ARIHPWH-40-T (3.55 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks