Skip to main content
ENERGY STAR water heater model · PD 4689623

State CSHP-66 2** Water Heater Specifications (3.84 UEF)

With PD 4689623 certification, State CSHP-66 2** (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.84 UEF rating across its 68-gallon nominal tank, 83 gal First Hour Rating, standing #221 of 706 across 706 peers with Pass: +1.34 / +53.6% for May 6, 2029. Rated annual electricity draw of 1,292 kWh/yr equates to roughly $235/yr ($2,346 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith CAHP-66 2** (3.84 UEF).

Uniform Energy Factor
3.84 UEF
Cohort UEF Rank
#221 of 706 (top 32.4%)
First Hour Rating
83 gal
Storage Volume
68 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.34 / +53.6%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking State CSHP-66 2** at 3.84 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50State CSHP-66 2**: 3.84
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows State CSHP-66 2** relative to the cohort median.
Efficiency comparison & rule summary

ENERGY STAR certification places State CSHP-66 2** at 3.84 UEF (#221 of 706; +0.14 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.

May 6, 2029 readiness: State CSHP-66 2** stands +1.34 UEF (+53.6%) relative to 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,292 kWh/yr for State CSHP-66 2** runs ~$235/yr vs. ~$979/yr for a 0.92 UEF electric tank.

State electric sensitivity for State CSHP-66 2**: 10-year operating spend spans $1,890 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,096 in Hawaii (Highest EIA State) (47.18 cents/kWh).

In the Hybrid/Electric Heat Pump tier, A. O. Smith CAHP-66 2** (3.84 UEF, at parity) and American HPA10266H045DV 2** (3.84 UEF, at parity) bracket State CSHP-66 2**.

How Complete Are the Certified Metrics for State CSHP-66 2**?

Standing at #221 of 706 (top 32.4%) among 706 certified Hybrid/Electric Heat Pump heaters, State CSHP-66 2** brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandState81 certified listingsENERGY STAR PD 4689623
Model NumberCSHP-66 2**Draw pattern: High-UsageCSHP-66 2**
Uniform Energy Factor (UEF)3.84+0.14 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)83 gal+11 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,292 kWh/yr+220 kWh/yr vs. 1,072 kWh/yr medianEst. $235/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency435%+6.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)61" H x 23" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 22 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2026-08-13Certified 2026-08-13Markets: United States

What Is the Projected Utility Bill for CSHP-66 2** by State?

At 1,292 kWh/yr, State CSHP-66 2** averages about $235/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.

Estimated Annual Electricity Cost by State Rate (1,292 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$235.00/yrHawaii$610.00/yrCalifornia$384.00/yrTexas$206.00/yrWashington$189.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $235/yr $2,346 $7,447
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $610/yr $6,096 $19,349
California 29.75 ¢/kWh ($0.2975) $384/yr $3,844 $12,200
Texas 15.91 ¢/kWh ($0.1591) $206/yr $2,056 $6,525
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $189/yr $1,890 $6,000
Estimated electricity spend (1,292 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are State Models Affected by Current CPSC Notices?

Review 4 brand-matched CPSC entries pulled 2026-11-23 for State and confirm your serial tag before scheduling contractor service. See Serial Number Lookup.

4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #08241 (2008-04-03): A.O. Smith Recalls Gas Water Heaters Due to Fire and Carbon Monoxide Hazards (CPSC Notice)
  • Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
  • Recall #04128 (2004-04-28): CPSC, White-Rodgers Announce Recall of LP and Convertible Gas Water Heater Temperature Controls (CPSC Notice)

Which 5 Models Offer Similar Output to CSHP-66 2**?

Ordered by minimal capacity and UEF spread relative to State CSHP-66 2**, these five certified peers give direct replacement benchmarks.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith CAHP-66 2** Hybrid/Electric Heat Pump 68 gal 83 gal 3.84 (at parity) 1,292
American HPA10266H045DV 2** Hybrid/Electric Heat Pump 68 gal 83 gal 3.84 (at parity) 1,292
Lochinvar CHPA-66 2** Hybrid/Electric Heat Pump 68 gal 83 gal 3.84 (at parity) 1,292
RELIANCE WATER HEATERS 10-66-DHPTA 2** Hybrid/Electric Heat Pump 68 gal 83 gal 3.84 (at parity) 1,292
A. O. Smith HPA10-66H45DV 2** Hybrid/Electric Heat Pump 68 gal 83 gal 3.84 (at parity) 1,292

What Installation Caveats Apply Before Buying State CSHP-66 2**?

Even high-UEF units like State CSHP-66 2** (3.84 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

Key Limitations & Exclusions

  • State CSHP-66 2** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting State CSHP-66 2** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing State CSHP-66 2** Strong Fit — 3.84 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare A. O. Smith CAHP-66 2** footprint.

Practical Specs & Code Questions for State CSHP-66 2**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Is State CSHP-66 2** eligible for continued manufacture past May 6, 2029?

At 3.84 UEF, State CSHP-66 2** achieves Pass: +1.34 / +53.6% for the 2029 DOE standard and stands #221 of 706 (top 32.4%) against A. O. Smith CAHP-66 2** and American HPA10266H045DV 2**.

How tall and wide is State CSHP-66 2**, and what service clearance is needed?

Physical dimensions for State CSHP-66 2** are 61 in. height and 23 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" d)); verify stair turns and drain pan width before delivery.

Will State CSHP-66 2** require upgrading household electrical panels or gas piping?

State CSHP-66 2** draws 240V at 22A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.

Is State CSHP-66 2** economical to operate at 18.16 cents/kWh US electric rates?

Expect roughly $235/yr ($2,350 over 10 years) to power State CSHP-66 2** at 1,292 kWh/yr under the 18.16 cents/kWh US average (ranging from $189/yr in Washington hydro tiers up to $610/yr in Hawaii).

Which installation bottlenecks limit State CSHP-66 2**?

If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, State CSHP-66 2** drops into resistance mode more often.

How does State CSHP-66 2** handle simultaneous showers and laundry?

Delivering 83 gal in the first hour (+11 gal vs. 72 gal median), State CSHP-66 2** combines 68 gal tank storage with rapid burner/element recovery.

How long is the warranty on State CSHP-66 2** and how do you decode its serial?

CPSC SaferProducts records show 4 brand-level recall notices mentioning State as of 2026-11-23, including #19029 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

How do 2026 post-OBBBA rebates affect buying State CSHP-66 2**?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is A. O. Smith CAHP-66 2** (3.84 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks